Low frequency cMUT technology: Application to measurement of brain movement and assessment of bone quality

被引:7
|
作者
Certon, D. [1 ]
Ternifi, R. [2 ]
Boulme, A. [1 ]
Legros, M. [3 ]
Minonzio, J. -G. [4 ]
Talmant, M. [4 ]
Patat, F. [5 ]
Remenieras, J. -P. [2 ]
机构
[1] Univ Tours, GREMAN UMR CNRS 7347, F-37032 Tours, France
[2] Univ Tours, INSERM U930, F-37032 Tours, France
[3] Vermon SA, Tours, France
[4] UPMC Univ Paris 06, LIP UMR CNRS 7623, Paris, France
[5] Bretonneau Hosp, CHRU CIC IT, F-37044 Tours, France
关键词
AXIAL TRANSMISSION; LONG BONES; IN-VITRO; TISSUE; ULTRASOUND; TRANSDUCERS; INTEGRATION; PRECISION; ARRAYS; PLATES;
D O I
10.1016/j.irbm.2013.01.009
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Following recent advances in medical ultrasound imaging methods almost all human tissues can currently be examined. There are, however, two exceptions: the human skeleton and the brain, because bone tissue is a strongly attenuating and defocusing medium, rendering classical pulse-echo imaging methods inappropriate. Specific imaging approaches within low frequency bands, i.e. 200 kHz-2 MHz, have therefore recently been developed and the results are very promising: (1) the technique for the bone is axial transmission measurement, which consists of using elastic guided modes to characterize all elastic constants of the medium; (2) for brain exploration, it has been demonstrated that brain movement can be measured (i.e. brain pulsatility) with elastography techniques. However, there are certain limitations in the fabrication of low frequency probes with classical technology, which involve finding an alternative to the traditional PZT. Capacitive Micromachined Ultrasonic Transducers (cMUTs) can overcome these limitations and greatly improve these new imaging modalities. The study presented here represents technological development with several goals: (1) the design and fabrication of two different low frequency linear arrays for bone and brain exploration, respectively the testihg of axial transmission measurements with a cMUT probe and; (2) comparison with a PZT probe; (3) the development of an imaging method based on the elastography of brain pulsatility, its implementation in a commercial ultrasound scanner and clinical trials for the validation. The results obtained with cMUT and PZT probes are compared. (C) 2013 Elsevier Masson SAS. All rights reserved.
引用
收藏
页码:159 / 166
页数:8
相关论文
共 50 条
  • [21] Application of Phased Array Technology for Identification of Low Frequency Noise Sources
    Camargo, Hugo E.
    Ravetta, Patricio A.
    Burdisso, Ricardo A.
    Smith, Adam K.
    JOURNAL OF LOW FREQUENCY NOISE VIBRATION AND ACTIVE CONTROL, 2009, 28 (04): : 237 - 244
  • [22] Effects of low frequency magnetic fields (LFMF) on bone quality and bone metabolism in ovariectomized rats
    Zhang, XY
    Xue, Y
    BONE, 2001, 28 (05) : S219 - S219
  • [23] Assessment of range and quality of neck movement using a smartphone-based application
    Palsson, T. S.
    Christensen, S. W.
    Thomsen, M. H.
    Hirata, R. P.
    MUSCULOSKELETAL SCIENCE AND PRACTICE, 2019, 41 : 64 - 69
  • [24] APPLICATION OF A CAPTOR WITH NON-LINEAR INDUCTANCE TO LOW FREQUENCY MEASUREMENT
    NADAL, J
    PERROUD, J
    SURCHAMP, Y
    TRANNOY, B
    COMPTES RENDUS HEBDOMADAIRES DES SEANCES DE L ACADEMIE DES SCIENCES SERIE B, 1969, 268 (06): : 463 - &
  • [25] Heart Rate Variability (HRV) Measurement- A Methodological Application of Low Frequency measurement in LabVIEW
    Sharma, M. L.
    Verma, Ravi Kant
    Rizvi, Noor Fatima
    Malhotra, Anu
    Sharma, Swati
    Sharma, Nipun
    INTERNATIONAL JOURNAL OF COMPUTER SCIENCE AND NETWORK SECURITY, 2011, 11 (02): : 105 - 108
  • [26] Assessment of bone quality in the proximal humerus by measurement of the contralateral site: a cadaveric analyze
    Diederichs, G
    Korner, J
    Goldhahn, J
    Linke, B
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2006, 126 (02) : 93 - 100
  • [27] Assessment of bone quality in the proximal humerus by measurement of the contralateral site: a cadaveric analyze
    Gerd Diederichs
    Jan Korner
    Jörg Goldhahn
    Berend Linke
    Archives of Orthopaedic and Trauma Surgery, 2006, 126 : 93 - 100
  • [28] Low complexity image quality assessment using frequency domain transforms
    Sendashonga, Mireille
    Labeau, Fabrice
    2006 IEEE INTERNATIONAL CONFERENCE ON IMAGE PROCESSING, ICIP 2006, PROCEEDINGS, 2006, : 385 - +
  • [29] A low-cost tide measurement system for water quality assessment
    Pereira, J. M. Dias
    Postolache, O.
    Girao, P. Silva
    2006 IEEE INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE PROCEEDINGS, VOLS 1-5, 2006, : 2226 - +
  • [30] ASSESSMENT OF BONE METABOLISM AND QUALITY OF LIFE IN KNEE OSTEOARTHRITIS PATIENTS WITH LOW BONE MINERAL DENSITY
    Hu, N.
    Zhang, J.
    Wang, P.
    Wang, J.
    Qiang, Y.
    Li, Z.
    Wu, T.
    Wang, X.
    Wang, Y.
    Li, J.
    Liu, X.
    Zhang, J.
    Feng, X.
    Ju, B.
    Hao, Z.
    Pu, D.
    Lv, X.
    Wang, Q.
    He, L.
    OSTEOARTHRITIS AND CARTILAGE, 2020, 28 : S433 - S433