Low frequency cMUT technology: Application to measurement of brain movement and assessment of bone quality

被引:7
|
作者
Certon, D. [1 ]
Ternifi, R. [2 ]
Boulme, A. [1 ]
Legros, M. [3 ]
Minonzio, J. -G. [4 ]
Talmant, M. [4 ]
Patat, F. [5 ]
Remenieras, J. -P. [2 ]
机构
[1] Univ Tours, GREMAN UMR CNRS 7347, F-37032 Tours, France
[2] Univ Tours, INSERM U930, F-37032 Tours, France
[3] Vermon SA, Tours, France
[4] UPMC Univ Paris 06, LIP UMR CNRS 7623, Paris, France
[5] Bretonneau Hosp, CHRU CIC IT, F-37044 Tours, France
关键词
AXIAL TRANSMISSION; LONG BONES; IN-VITRO; TISSUE; ULTRASOUND; TRANSDUCERS; INTEGRATION; PRECISION; ARRAYS; PLATES;
D O I
10.1016/j.irbm.2013.01.009
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Following recent advances in medical ultrasound imaging methods almost all human tissues can currently be examined. There are, however, two exceptions: the human skeleton and the brain, because bone tissue is a strongly attenuating and defocusing medium, rendering classical pulse-echo imaging methods inappropriate. Specific imaging approaches within low frequency bands, i.e. 200 kHz-2 MHz, have therefore recently been developed and the results are very promising: (1) the technique for the bone is axial transmission measurement, which consists of using elastic guided modes to characterize all elastic constants of the medium; (2) for brain exploration, it has been demonstrated that brain movement can be measured (i.e. brain pulsatility) with elastography techniques. However, there are certain limitations in the fabrication of low frequency probes with classical technology, which involve finding an alternative to the traditional PZT. Capacitive Micromachined Ultrasonic Transducers (cMUTs) can overcome these limitations and greatly improve these new imaging modalities. The study presented here represents technological development with several goals: (1) the design and fabrication of two different low frequency linear arrays for bone and brain exploration, respectively the testihg of axial transmission measurements with a cMUT probe and; (2) comparison with a PZT probe; (3) the development of an imaging method based on the elastography of brain pulsatility, its implementation in a commercial ultrasound scanner and clinical trials for the validation. The results obtained with cMUT and PZT probes are compared. (C) 2013 Elsevier Masson SAS. All rights reserved.
引用
收藏
页码:159 / 166
页数:8
相关论文
共 50 条
  • [1] Application of a novel bone simulator to the assessment of bone quality
    Langton, CM
    Dobson, CA
    Phillips, R
    Fagan, MJ
    JOURNAL OF BONE AND MINERAL RESEARCH, 2005, 20 (07) : 1300 - 1300
  • [2] An Experimental Protocol for Assessing the Performance of New Ultrasound Probes Based on CMUT Technology in Application to Brain Imaging
    Matrone, Giulia
    Ramalli, Alessandro
    Savoia, Alessandro Stuart
    Quaglia, Fabio
    Castellazzi, Gloria
    Morbini, Patrizia
    Piastra, Marco
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2017, (127):
  • [3] Development of measurement and assessment technology for evaluation of bone regeneration
    Kotobuki, Noriko
    Hirose, Motohiro
    Ioku, Koji
    Sakaguchi, Akira
    Iwama, Akifurni
    Harada, Masaki
    Yamamoto, Hiroshi
    Ohgushi, Hajime
    BIOCERAMICS, VOL 20, PTS 1 AND 2, 2008, 361-363 : 997 - +
  • [4] Low-frequency deep brain stimulation for movement disorders
    Baizabal-Carvallo, Jose Fidel
    Alonso-Juarez, Marlene
    PARKINSONISM & RELATED DISORDERS, 2016, 31 : 14 - 22
  • [5] A Review of Low-Frequency EPR Technology for the Measurement of Brain pO2 and Oxidative Stress
    Weaver, John
    Liu, Ke Jian
    APPLIED MAGNETIC RESONANCE, 2021, 52 (10) : 1379 - 1394
  • [6] A Review of Low-Frequency EPR Technology for the Measurement of Brain pO2 and Oxidative Stress
    John Weaver
    Ke Jian Liu
    Applied Magnetic Resonance, 2021, 52 : 1379 - 1394
  • [7] Blurriness measurement in frequency domain for image quality assessment
    Tahir, Qadri Muhammad
    Noman, Mehmood Syed
    Tahir, Aisha
    INTERNATIONAL CONFERENCE ON GRAPHIC AND IMAGE PROCESSING (ICGIP 2011), 2011, 8285
  • [8] LOW-FREQUENCY VIBRATION IN APPLICATION OF BONE-CEMENT
    THOMAS, AMC
    DUNN, JW
    LUO, DZ
    LANCET, 1988, 1 (8577): : 116 - 117
  • [9] Low frequency screening effect in urban areas and the engineering measurement technology
    Liu, H
    Wu, WH
    Chen, HM
    Meng, QB
    1997 INTERNATIONAL SYMPOSIUM ON ELECTROMAGNETIC COMPATIBILITY, PROCEEDINGS, 1997, : 106 - 109
  • [10] The Role of Multi-Sensor Measurement in the Assessment of Movement Quality: A Systematic Review
    T. Alexander Swain
    Melitta A. McNarry
    Adam W. H. Runacres
    Kelly A. Mackintosh
    Sports Medicine, 2023, 53 : 2477 - 2504