Influence of automated visual field testing on intraocular pressure

被引:0
|
作者
Bertaud, Samuel [1 ]
Skarbek Borowski, Elisabeth [1 ]
Abbas, Rachid [2 ,3 ]
Baudouin, Christophe [1 ,4 ,5 ]
Labbe, Antoine [1 ,4 ,5 ]
机构
[1] Quinze Vingts Natl Ophthalmol Hosp, IHU FOReSIGHT, INSERM DGOS CIC 1423, 28 Rue Charenton, F-75012 Paris, France
[2] Gustave Roussy, Dept Biostat & Epidemiol, Villejuif, France
[3] Univ Paris Saclay, Univ Paris Sud, INSERM U1018, CESP, Villejuif, France
[4] Univ Paris Saclay, Univ Versailles St Quentin Yvelines, Ambroise Pare Hosp, AP HP,IHU FOReSIGHT,Dept Ophthalmol, Versailles, France
[5] Sorbonne Univ, CNRS, INSERM, Inst Vis,IHU FOReSIGHT, Paris, France
关键词
Glaucoma; VF testing; intraocular pressure; OPEN-ANGLE GLAUCOMA; ACCOMMODATION;
D O I
10.1186/s12886-020-01622-7
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Background To evaluate the influence of automated visual field (VF) testing on intraocular pressure (IOP) in patients with ocular hypertension (OHT) or glaucoma. Methods We conducted a prospective observational study in the glaucoma department at Quinze-Vingts National Ophthalmology Hospital in Paris. Ninety-five right eyes of 95 patients followed for glaucoma or OHT were included. IOP was measured three times using a Nidek NT-510 non-contact tonometer within a maximum of 5 min before and after VF testing. Sub analyses using logistic regression analysis were performed to evaluate the impact of gender, age, central corneal thickness (CCT), mean deviation (MD) of the VF, VF test duration and filtration surgery on IOP fluctuations. Results There was no significant change in IOP after VF testing, with IOP's 15.14 +/- 4.00 mmHg before and 14.98 +/- 3.33 mmHg after the VF (P = 0.4). The average change in IOP was 0.15 +/- 1.82 mmHg. Using multivariate analysis, no effect of the VF test on IOP was found (global model fit R-2 = 0.12), whether based on duration of the VF test (P = 0.18) or the MD (P = 0.7) after adjustment for age, gender, CCT and history of glaucoma surgery. Similarly, there was no significant difference within different types of glaucoma, including open-angle glaucoma(P = 0.36),chronic angle closure glaucoma (P = 0.85) and OHT (P = 0.42). The subgroup of patients with an IOP elevation >= 2 mmHg had a significantly higher VF test duration (P = 0.002). Conclusion VF testing does not influence IOP as measured with a non-contact tonometer.
引用
收藏
页数:6
相关论文
共 50 条
  • [41] Intraocular pressure and visual field progression in open-angle glaucoma
    Kass, MA
    Gordon, MO
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2000, 130 (04) : 490 - 491
  • [42] RELATIONSHIP BETWEEN INTRAOCULAR-PRESSURE AND VISUAL-FIELD DEFECTS
    FRIEDMANN, AI
    EXPERIMENTAL EYE RESEARCH, 1975, 20 (02) : 182 - 182
  • [43] Influence of optic disc appearance and diurnal variation of intraocular pressure on visual field defect in normal tension glaucoma
    Yamazaki, Y
    Nakagami, T
    Oshida, T
    Mizuki, K
    Hayamizu, F
    Tanaka, C
    PERIMETRY UPDATE 2002/2003, 2004, : 165 - 171
  • [44] Influence of extended depth of focus intraocular lenses on visual field sensitivity
    Takahashi, Makiko
    Yamashiro, Chiemi
    Yoshimoto, Takuya
    Kobayashi, Yuka
    Higashijima, Fumiaki
    Kobayashi, Masaaki
    Hatano, Makoto
    Ohta, Manami
    Nagai, Tomohiko
    Teranishi, Shinichiro
    Suzuki, Katsuyoshi
    Takabatake, Ryu
    Kimura, Kazuhiro
    PLOS ONE, 2020, 15 (09):
  • [45] FOCAL AND DIFFUSE VISUAL-FIELD DEFECTS - THEIR RELATIONSHIP TO INTRAOCULAR-PRESSURE
    SAMUELSON, TW
    SPAETH, GL
    OPHTHALMIC SURGERY AND LASERS, 1993, 24 (08): : 519 - 525
  • [46] Factors associated with intraocular pressure-induced acute visual field depression
    Trible, JR
    Anderson, DR
    ARCHIVES OF OPHTHALMOLOGY, 1997, 115 (12) : 1523 - 1527
  • [47] FOCAL AND DIFFUSE VISUAL-FIELD DEFECTS RELATED TO INTRAOCULAR-PRESSURE
    KIRBER, WM
    OPHTHALMIC SURGERY AND LASERS, 1994, 25 (01): : 60 - 60
  • [48] ANALYSIS OF PROGRESSIVE CHANGE IN AUTOMATED VISUAL-FIELD TESTING IN GLAUCOMA
    SMITH, SD
    KATZ, S
    QUIGLEY, HA
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1995, 36 (04) : S219 - S219
  • [49] VISUAL-FIELD CHANGES FOLLOWING ACUTE ELEVATION OF INTRAOCULAR-PRESSURE
    RADIUS, RL
    MAUMENEE, AE
    TRANSACTIONS AMERICAN ACADEMY OF OPHTHALMOLOGY AND OTOLARYNGOLOGY, 1976, 81 (04): : P127 - P128
  • [50] Relationship Between Intraocular Pressure and Rate of Visual Field Progression in Treated Glaucoma
    Rao, Harsha L.
    Addepalli, Uday K.
    Jonnadula, Ganesh B.
    Kumbar, Tukaram
    Senthil, Sirisha
    Garudadri, Chandra S.
    JOURNAL OF GLAUCOMA, 2013, 22 (09) : 719 - 724