Influence of automated visual field testing on intraocular pressure

被引:0
|
作者
Bertaud, Samuel [1 ]
Skarbek Borowski, Elisabeth [1 ]
Abbas, Rachid [2 ,3 ]
Baudouin, Christophe [1 ,4 ,5 ]
Labbe, Antoine [1 ,4 ,5 ]
机构
[1] Quinze Vingts Natl Ophthalmol Hosp, IHU FOReSIGHT, INSERM DGOS CIC 1423, 28 Rue Charenton, F-75012 Paris, France
[2] Gustave Roussy, Dept Biostat & Epidemiol, Villejuif, France
[3] Univ Paris Saclay, Univ Paris Sud, INSERM U1018, CESP, Villejuif, France
[4] Univ Paris Saclay, Univ Versailles St Quentin Yvelines, Ambroise Pare Hosp, AP HP,IHU FOReSIGHT,Dept Ophthalmol, Versailles, France
[5] Sorbonne Univ, CNRS, INSERM, Inst Vis,IHU FOReSIGHT, Paris, France
关键词
Glaucoma; VF testing; intraocular pressure; OPEN-ANGLE GLAUCOMA; ACCOMMODATION;
D O I
10.1186/s12886-020-01622-7
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Background To evaluate the influence of automated visual field (VF) testing on intraocular pressure (IOP) in patients with ocular hypertension (OHT) or glaucoma. Methods We conducted a prospective observational study in the glaucoma department at Quinze-Vingts National Ophthalmology Hospital in Paris. Ninety-five right eyes of 95 patients followed for glaucoma or OHT were included. IOP was measured three times using a Nidek NT-510 non-contact tonometer within a maximum of 5 min before and after VF testing. Sub analyses using logistic regression analysis were performed to evaluate the impact of gender, age, central corneal thickness (CCT), mean deviation (MD) of the VF, VF test duration and filtration surgery on IOP fluctuations. Results There was no significant change in IOP after VF testing, with IOP's 15.14 +/- 4.00 mmHg before and 14.98 +/- 3.33 mmHg after the VF (P = 0.4). The average change in IOP was 0.15 +/- 1.82 mmHg. Using multivariate analysis, no effect of the VF test on IOP was found (global model fit R-2 = 0.12), whether based on duration of the VF test (P = 0.18) or the MD (P = 0.7) after adjustment for age, gender, CCT and history of glaucoma surgery. Similarly, there was no significant difference within different types of glaucoma, including open-angle glaucoma(P = 0.36),chronic angle closure glaucoma (P = 0.85) and OHT (P = 0.42). The subgroup of patients with an IOP elevation >= 2 mmHg had a significantly higher VF test duration (P = 0.002). Conclusion VF testing does not influence IOP as measured with a non-contact tonometer.
引用
收藏
页数:6
相关论文
共 50 条
  • [31] Acute effects of sildenafil on Humphrey visual field and intraocular pressure
    Ermis S.S.
    Inan U.U.
    Samli M.
    Ozturk F.
    International Ophthalmology, 2004, 25 (2) : 69 - 72
  • [32] Variations in intraocular pressure after visual field examination - Reply
    Recupero, SM
    Contestabile, MT
    Taverniti, L
    Villani, GM
    Recupero, V
    JOURNAL OF GLAUCOMA, 2004, 13 (02)
  • [33] Intraocular pressure and central visual field of normal tension glaucoma
    Araie, M
    Kitazawa, M
    Koseki, N
    BRITISH JOURNAL OF OPHTHALMOLOGY, 1997, 81 (10) : 852 - 856
  • [34] Postural influence on intraocular pressure and visual field defects in open angle glaucoma and normal tension glaucoma
    Sampaio Meirelles, Sergio Henrique
    Mathias, Cristina Rodrigues
    Brandao, Gilberto
    de Arantes Frota, Ana Carolina
    Yamane, Riuitiro
    REVISTA BRASILEIRA DE OFTALMOLOGIA, 2008, 67 (01) : 19 - 24
  • [35] CONTRAST SENSITIVITY VERSUS STATIC VISUAL-FIELD TESTING DURING EXPERIMENTAL ELEVATION OF INTRAOCULAR-PRESSURE
    FRIBERG, TR
    SANBORN, GE
    BUDD, R
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 1989, 227 (04) : 345 - 347
  • [36] A comparison of visual field testing with a new automated perimeter, the Compass visual field analyser, and the Humphrey visual field analyser
    Fenolland, J. R.
    Bonnel, S.
    Rosenberg, R.
    Sendon, D.
    Ghazal, W.
    Giraud, J. M.
    Renard, J. P.
    ACTA OPHTHALMOLOGICA, 2016, 94
  • [37] The Effect of the Automated Visual Field Examination on Intraocular Preure (IOP) in Patients with Glaucoma
    Makhni, Sonya
    Dave, Dipali
    Karl, Matthew
    Serle, Janet
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (15)
  • [38] Visual field and intraocular pressure asymmetry in the low-pressure glaucoma treatment study
    Greenfield, David S.
    Liebmann, Jeffrey M.
    Ritch, Robert
    Krupin, Theodore
    OPHTHALMOLOGY, 2007, 114 (03) : 460 - 465
  • [39] Progressing Scintillating Scotoma Captured on Automated Visual Field Testing
    Yohannan, Jithin
    Jampel, Henry
    OPHTHALMOLOGY, 2016, 123 (06) : 1395 - 1396
  • [40] OCT angiography, RNFL and the visual field at different values of intraocular pressure
    Kral, Jakub
    Lestak, Jan
    Nutterova, Elena
    BIOMEDICAL REPORTS, 2022, 16 (05)