Health evaluation of carbon dioxide in indoor air

被引:10
|
作者
不详
机构
关键词
carbon dioxide; indoor air; ventilation; evaluation; health effects; guideline value;
D O I
10.1007/s00103-008-0707-2
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
.For over 150 years, carbon dioxide has been an acknowledged indicator of indoor air quality. To estimate the air quality in mechanically ventilated buildings, DIN EN 13779 proposes four different levels of indoor carbon dioxide concentration. However, apart from the early guideline value of 1000 ppm carbon dioxide recommended by Pettenkofer in 1858, there is no actual guideline value for naturally ventilated buildings. Regarding recent intervention studies, the German Working Group on Indoor Guideline Values of the Federal Environmental Agency and the States' Health Authorities therefore recommends the following guide values, based on health and hygiene considerations: concentrations of indoor air carbon dioxide below 1000 ppm are regarded as harmless, those between 1000 and 2000 ppm as elevated and those above 2000 ppm as unacceptable. In addition to the recommendations for TVOC values, this further assists in the assessment of indoor air quality.
引用
收藏
页码:1358 / 1369
页数:12
相关论文
共 50 条
  • [1] Association of carbon dioxide with indoor air pollutants and exceedance of health guideline values
    Ramalho, Olivier
    Wyart, Guillaume
    Mandin, Corinne
    Blondeau, Patrice
    Cabanes, Pierre-Andre
    Leclerc, Nathalie
    Mullot, Jean-Ulrich
    Boulanger, Guillaume
    Redaelli, Matteo
    [J]. BUILDING AND ENVIRONMENT, 2015, 93 : 115 - 124
  • [2] Dynamics of carbon dioxide concentration in indoor air
    Szczurek, Andrzej
    Maciejewska, Monika
    Poloczanski, Rafal
    Teuerle, Marek
    Wylomanska, Agnieszka
    [J]. STOCHASTIC ENVIRONMENTAL RESEARCH AND RISK ASSESSMENT, 2015, 29 (08) : 2193 - 2199
  • [3] Dynamics of carbon dioxide concentration in indoor air
    Andrzej Szczurek
    Monika Maciejewska
    Rafał Połoczański
    Marek Teuerle
    Agnieszka Wyłomańska
    [J]. Stochastic Environmental Research and Risk Assessment, 2015, 29 : 2193 - 2199
  • [4] The impact evaluation of carbon dioxide concentration on energy consumption analyzing indoor air quality
    Butala, V
    [J]. STROJARSTVO, 1999, 41 (1-2): : 27 - 34
  • [5] Evaluation of indoor air quality using the decibel concept based on carbon dioxide and TVOC
    Jokl, MV
    [J]. BUILDING AND ENVIRONMENT, 2000, 35 (08) : 677 - 697
  • [6] Carbon dioxide guidelines for indoor air quality: a review
    Mendell, Mark J.
    Chen, Wenhao
    Ranasinghe, Dilhara R.
    Castorina, Rosemary
    Kumagai, Kazukiyo
    [J]. JOURNAL OF EXPOSURE SCIENCE AND ENVIRONMENTAL EPIDEMIOLOGY, 2024, 34 (04) : 555 - 569
  • [7] Use of adsorbents for indoor air purification from carbon dioxide
    Zubkova, Marina Yu.
    Maslikov, Vladimir I.
    Molodtsov, Dmitry V.
    Chusov, Alexander N.
    Gabdullina, Ekaterina P.
    [J]. APPLIED MECHANICS, MATERIALS AND MANUFACTURING IV, 2014, 670-671 : 229 - 234
  • [8] MEASUREMENT OF CARBON-DIOXIDE OF THE INDOOR AIR TO CONTROL THE FRESH AIR SUPPLY
    FECKER, I
    WANNER, HU
    [J]. SOZIAL-UND PRAVENTIVMEDIZIN, 1985, 30 (4-5): : 268 - 269
  • [9] CARBON-DIOXIDE CONCENTRATION AS INDICATOR OF INDOOR AIR-QUALITY
    HUNG, IF
    DEROSSIS, P
    [J]. JOURNAL OF ENVIRONMENTAL SCIENCE AND HEALTH PART A-ENVIRONMENTAL SCIENCE AND ENGINEERING & TOXIC AND HAZARDOUS SUBSTANCE CONTROL, 1989, 24 (04): : 379 - 388
  • [10] Using carbon dioxide concentration to assess indoor air quality in offices
    Hui, P. S.
    Wong, L. T.
    Mui, K. W.
    [J]. INDOOR AND BUILT ENVIRONMENT, 2008, 17 (03) : 213 - 219