Carbon dioxide guidelines for indoor air quality: a review

被引:1
|
作者
Mendell, Mark J. [1 ]
Chen, Wenhao [1 ]
Ranasinghe, Dilhara R. [1 ]
Castorina, Rosemary [1 ]
Kumagai, Kazukiyo [1 ]
机构
[1] Calif Dept Publ Hlth, Ctr Lab Sci, Air Qual Sect, Richmond, CA 94804 USA
关键词
Ventilation; Standards; COVID-19; VENTILATION RATES; HEALTH; CO2; STANDARDS;
D O I
10.1038/s41370-024-00694-7
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
BACKGROUND: The importance of building ventilation to protect health has been more widely recognized since the COVID-19 pandemic. Outdoor air ventilation in buildings dilutes indoor-generated air pollutants (including bioaerosols) and reduces resulting occupant exposures. Many countries and organizations have advisory guidelines or mandatory standards for minimum ventilation rates (VRs) to maintain indoor air quality (IAQ). Because directly measuring VRs is often difficult, many IAQ guidelines instead specify indoor concentration limits for carbon dioxide (CO2), using CO2 exhaled by building occupants as an indicator of VR. Although indoor CO2 guidelines are common, the evidence basis for the various CO2 limits has not been clear. OBJECTIVE: To review current indoor CO2 guidelines worldwide and the supportive evidence provided. METHODS: We identified worldwide CO2-based guidelines for IAQ or ventilation, along with any supportive evidence provided. We excluded occupational guidelines for CO2 levels >= 5000 ppm. RESULTS: Among 43 guidelines identified, 35 set single CO2 concentration limits and eight set multi-tiered limits; 16 mentioned no specific human effect to be controlled, 19 specified only odor dissatisfaction, five specified non-infectious health effects, and three specified airborne infectious disease transmission. The most common indoor CO2 limit was 1000 ppm. Thirteen guidelines specified maximum CO2 limits as extended time-weighted averages, none with evidence linking averaged limits to occupant effects. Of only 18 guidelines citing evidence to support limits set, we found this evidence persuasive for eight. Among these eight guidelines, seven set limits to control odor perception. One provided 17 scientifically-based CO2 limits, for specific example space uses and occupancies, to control long-range COVID-19 transmission indoors. IMPACT: Many current indoor carbon dioxide (CO2) guidelines for indoor air quality specified no adverse effects intended for control. Odor dissatisfaction was the effect mentioned most frequently, few mentioned health, and three mentioned control of infectious disease. Only one CO2 guideline was developed from scientific models to control airborne transmission of COVID-19. Most guidelines provided no supportive evidence for specified limits; few provided persuasive evidence. No scientific basis is apparent for setting one CO2 limit for IAQ across all buildings, setting a CO2 limit for IAQ as an extended time-weighted average, or using a one-time CO2 measurement to verify a desired VR.
引用
收藏
页码:555 / 569
页数:15
相关论文
共 50 条
  • [1] Indoor air quality guidelines
    Harrison, PTC
    [J]. OCCUPATIONAL AND ENVIRONMENTAL MEDICINE, 2002, 59 (02) : 73 - 74
  • [2] A Systematic Review of Air Quality Sensors, Guidelines, and Measurement Studies for Indoor Air Quality Management
    Zhang, He
    Srinivasan, Ravi
    [J]. SUSTAINABILITY, 2020, 12 (21) : 1 - 40
  • [3] CARBON-DIOXIDE CONCENTRATION AS INDICATOR OF INDOOR AIR-QUALITY
    HUNG, IF
    DEROSSIS, P
    [J]. JOURNAL OF ENVIRONMENTAL SCIENCE AND HEALTH PART A-ENVIRONMENTAL SCIENCE AND ENGINEERING & TOXIC AND HAZARDOUS SUBSTANCE CONTROL, 1989, 24 (04): : 379 - 388
  • [4] Using carbon dioxide concentration to assess indoor air quality in offices
    Hui, P. S.
    Wong, L. T.
    Mui, K. W.
    [J]. INDOOR AND BUILT ENVIRONMENT, 2008, 17 (03) : 213 - 219
  • [5] Development of French Indoor Air Quality Guidelines
    Mandin, Corinne
    Bonvallot, Nathalie
    Kirchner, Severine
    Keirsbulck, Marion
    Alary, Rene
    Cabanes, Pierre-Andre
    Dor, Frederic
    Le Moullec, Yvon
    Mullot, Jean-Ulrich
    Peel, Anne-Elisabeth
    Rousselle, Christophe
    [J]. CLEAN-SOIL AIR WATER, 2009, 37 (06) : 494 - 499
  • [6] A review of standards and guidelines set by international bodies for the parameters of indoor air quality
    Abdul-Wahab, Sabah Ahmed
    En, Stephen Chin Fah
    Elkamel, Ali
    Ahmadi, Lena
    Yetilmezsoy, Kaan
    [J]. ATMOSPHERIC POLLUTION RESEARCH, 2015, 6 (05) : 751 - 767
  • [8] Dynamics of carbon dioxide concentration in indoor air
    Szczurek, Andrzej
    Maciejewska, Monika
    Poloczanski, Rafal
    Teuerle, Marek
    Wylomanska, Agnieszka
    [J]. STOCHASTIC ENVIRONMENTAL RESEARCH AND RISK ASSESSMENT, 2015, 29 (08) : 2193 - 2199
  • [9] Dynamics of carbon dioxide concentration in indoor air
    Andrzej Szczurek
    Monika Maciejewska
    Rafał Połoczański
    Marek Teuerle
    Agnieszka Wyłomańska
    [J]. Stochastic Environmental Research and Risk Assessment, 2015, 29 : 2193 - 2199
  • [10] CARBON DIOXIDE AND AIR QUALITY
    HELMS, JA
    [J]. JOURNAL OF FORESTRY, 1971, 69 (03) : 169 - &