Carbon dioxide guidelines for indoor air quality: a review

被引:1
|
作者
Mendell, Mark J. [1 ]
Chen, Wenhao [1 ]
Ranasinghe, Dilhara R. [1 ]
Castorina, Rosemary [1 ]
Kumagai, Kazukiyo [1 ]
机构
[1] Calif Dept Publ Hlth, Ctr Lab Sci, Air Qual Sect, Richmond, CA 94804 USA
关键词
Ventilation; Standards; COVID-19; VENTILATION RATES; HEALTH; CO2; STANDARDS;
D O I
10.1038/s41370-024-00694-7
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
BACKGROUND: The importance of building ventilation to protect health has been more widely recognized since the COVID-19 pandemic. Outdoor air ventilation in buildings dilutes indoor-generated air pollutants (including bioaerosols) and reduces resulting occupant exposures. Many countries and organizations have advisory guidelines or mandatory standards for minimum ventilation rates (VRs) to maintain indoor air quality (IAQ). Because directly measuring VRs is often difficult, many IAQ guidelines instead specify indoor concentration limits for carbon dioxide (CO2), using CO2 exhaled by building occupants as an indicator of VR. Although indoor CO2 guidelines are common, the evidence basis for the various CO2 limits has not been clear. OBJECTIVE: To review current indoor CO2 guidelines worldwide and the supportive evidence provided. METHODS: We identified worldwide CO2-based guidelines for IAQ or ventilation, along with any supportive evidence provided. We excluded occupational guidelines for CO2 levels >= 5000 ppm. RESULTS: Among 43 guidelines identified, 35 set single CO2 concentration limits and eight set multi-tiered limits; 16 mentioned no specific human effect to be controlled, 19 specified only odor dissatisfaction, five specified non-infectious health effects, and three specified airborne infectious disease transmission. The most common indoor CO2 limit was 1000 ppm. Thirteen guidelines specified maximum CO2 limits as extended time-weighted averages, none with evidence linking averaged limits to occupant effects. Of only 18 guidelines citing evidence to support limits set, we found this evidence persuasive for eight. Among these eight guidelines, seven set limits to control odor perception. One provided 17 scientifically-based CO2 limits, for specific example space uses and occupancies, to control long-range COVID-19 transmission indoors. IMPACT: Many current indoor carbon dioxide (CO2) guidelines for indoor air quality specified no adverse effects intended for control. Odor dissatisfaction was the effect mentioned most frequently, few mentioned health, and three mentioned control of infectious disease. Only one CO2 guideline was developed from scientific models to control airborne transmission of COVID-19. Most guidelines provided no supportive evidence for specified limits; few provided persuasive evidence. No scientific basis is apparent for setting one CO2 limit for IAQ across all buildings, setting a CO2 limit for IAQ as an extended time-weighted average, or using a one-time CO2 measurement to verify a desired VR.
引用
收藏
页码:555 / 569
页数:15
相关论文
共 50 条
  • [31] Quality of air in schools with the example of carbon dioxide
    Roscher, E
    Fromme, H
    [J]. GESUNDHEITSWESEN, 2005, 67 (03) : 247 - 247
  • [32] The Health Protection Act, national guidelines for indoor air quality and development of the national indoor air programs in Finland
    Husman, TM
    [J]. ENVIRONMENTAL HEALTH PERSPECTIVES, 1999, 107 : 515 - 517
  • [33] Dampness, Mould, and Health-a Review of Epidemiologic Evidence for the Upcoming WHO Guidelines for Indoor Air Quality
    Mendell, M. J.
    Mirer, A. G.
    [J]. EPIDEMIOLOGY, 2008, 19 (06) : S136 - S137
  • [34] Exhaled Carbon Dioxide as a Physiological Source of Deterioration of Indoor Air Quality in Non-Industrial Environments: Influence of Air Temperature
    Angelova, Radostina A.
    Markov, Detelin
    Velichkova, Rositsa
    Stankov, Peter
    Simova, Iskra
    [J]. ENERGIES, 2021, 14 (23)
  • [35] Low-Carbon Housings and Indoor Air Quality
    Yu, Chuck W. F.
    Kim, Jeong Tai
    [J]. INDOOR AND BUILT ENVIRONMENT, 2012, 21 (01) : 5 - 15
  • [36] Time to Review Air Quality Activity Guidelines
    Thakrar, Sumil K.
    [J]. JAMA NETWORK OPEN, 2024, 7 (04)
  • [37] Indoor Air Quality Guidelines Connection to IAQ Certification and Labelling Process
    Sprudza, Klinta Luize
    Klavina, Aneka
    Berzina, Buka
    Kauce, Ruta
    Martinsone, Zanna
    [J]. ENVIRONMENTAL AND CLIMATE TECHNOLOGIES, 2023, 27 (01) : 28 - 39
  • [38] Indoor air quality guidelines: Comparative analysis of approaches in France and Japan
    Rousselle, Christophe
    Mandin, Corinne
    Azuma, Kenichi
    [J]. ENVIRONNEMENT RISQUES & SANTE, 2011, 10 (01): : 25 - 34
  • [39] CANADA GUIDELINES FOR RESIDENTIAL INDOOR AIR-QUALITY - RATIONALE AND SCOPE
    ARMSTRONG, VC
    MEEK, MEB
    WALKINSHAW, DS
    [J]. NATO/CCMS WORKSHOP - PILOT STUDY ON INDOOR AIR QUALITY : MANAGING INDOOR AIR QUALITY RISKS, 1989, : 129 - 140