Conventional versus computer-assisted surgery in total knee arthroplasty: comparison at ten years follow-up

被引:26
|
作者
d'Amato, Michele [1 ]
Ensini, Andrea [1 ,2 ]
Leardini, Alberto [2 ]
Barbadoro, Paolo [1 ]
Illuminati, Andrea [1 ]
Belvedere, Claudio [2 ,3 ]
机构
[1] Ist Ortoped Rizzoli, Dept Orthopaed Surg, IRCCS, Via Barbiano 1-10, I-40136 Bologna, Italy
[2] Ist Ortoped Rizzoli, Movement Anal Lab, IRCCS, Via Barbiano 1-10, I-40136 Bologna, Italy
[3] Ist Ortoped Rizzoli, Movement Anal Lab & Funct Clin Evaluat Prostheses, Ctr Ric Codivilla Putti, Via Barbiano 1-10, I-40136 Bologna, Italy
关键词
Total knee arthroplasty; Computer-aided surgery; Surgical navigation; Clinical outcome; Long-term follow-up; CONTROLLED-TRIAL; NAVIGATION; ALIGNMENT; OUTCOMES; OSTEOARTHRITIS; REPLACEMENTS; KINEMATICS; PROSTHESES; AXIS;
D O I
10.1007/s00264-018-4114-5
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
PurposeComputer-assisted systems (CAS) for total knee arthroplasty (TKA) were expected to result in more accurate prosthesis implantation, better patient outcomes, and longer implant survival when compared to conventional instrumentation (CI). The aim of this study was to compare two groups of patients operated using CAS or CI at ten years follow-up.MethodsOne hundred twenty TKA patients, 60 using CAS and 60 using CI, were contacted after a decade for follow-up. Eligible patients received radiological examination to assess the lower-limb mechanical axis. They were also clinically assessed using the Knee Injury and Osteoarthritis Outcome Score (KOOS) and the Knee Society Score for Knee (KSS-K) and Function (KSS-F) Scoring. Kaplan-Meier survival analysis was performed to assess revisions, not for post-traumatic reasons.ResultsIn CAS and CI groups, the lower-limb mechanical axis was 1.7 degrees 2.4 degrees and 1.5 degrees +/- 2.8 degrees, respectively; corresponding KOOS values were 82.3 +/- 14.3 and 78.6 +/- 14.4; KSS-K values were 85.9 +/- 11.1 and 85.0 +/- 9.7; KSS-F values were 82.2 +/- 19.3 and 83.8 +/- 18. For these assessments, the differences between the two groups were not statistically significant (p>0.05). Two CAS (3.8%) and three CI patients (5.7%) were revised. The Kaplan-Meier analysis showed no significant differences between the two groups.Conclusionsp id=Par4No significant differences were found at long-term follow-up in terms of radiographical-clinical outcomes and of implant survival between TKA operated using CAS or CI.
引用
收藏
页码:1355 / 1363
页数:9
相关论文
共 50 条
  • [21] Is computer-assisted surgery in total knee arthroplasty as accurate as it can be?
    Lionberger, David R.
    Crocker, Catherine L.
    Rahbar, Mohammad H.
    COMPUTER AIDED SURGERY, 2012, 17 (04) : 198 - 204
  • [22] Improved Survival of Computer-Assisted Unicompartmental Knee Arthroplasty: 252 Cases With a Minimum Follow-Up of 5 Years
    Chowdhry, Majid
    Khakha, Raghbir S.
    Norris, Mark
    Kheiran, Amin
    Chauhan, Sandeep K.
    JOURNAL OF ARTHROPLASTY, 2017, 32 (04): : 1132 - 1136
  • [23] Computer navigation versus conventional implantation for varus knee total arthroplasty: A case-control study at 5 years follow-up
    Molfetta, Luigi
    Caldo, Davide
    KNEE, 2008, 15 (02): : 75 - 79
  • [24] Outcomes of Computer-Assisted Surgery Compared with Conventional Instrumentation in 19,221 Total Knee Arthroplasties: Results After a Mean of 4.5 Years of Follow-Up
    Roberts, Timothy D.
    Frampton, Christopher M.
    Young, Simon W.
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2020, 102 (07): : 550 - 556
  • [25] Robotic versus conventional primary total knee arthroplasty: clinical and radiological long-term results with a minimum follow-up of ten years
    Cho, Kyu-Jin
    Seon, Jong-Keun
    Jang, Won-Young
    Park, Chun-Gon
    Song, Eun-Kyoo
    INTERNATIONAL ORTHOPAEDICS, 2019, 43 (06) : 1345 - 1354
  • [26] Robotic versus conventional primary total knee arthroplasty: clinical and radiological long-term results with a minimum follow-up of ten years
    Kyu-Jin Cho
    Jong-Keun Seon
    Won-Young Jang
    Chun-Gon Park
    Eun-Kyoo Song
    International Orthopaedics, 2019, 43 : 1345 - 1354
  • [27] Differences in component and limb alignment between computer-assisted and conventional surgery total knee arthroplasty
    Tsan-Wen Huang
    Kuo-Ti Peng
    Kuo-Chin Huang
    Mel S. Lee
    Robert Wen-Wei Hsu
    Knee Surgery, Sports Traumatology, Arthroscopy, 2014, 22 : 2954 - 2961
  • [28] Differences in component and limb alignment between computer-assisted and conventional surgery total knee arthroplasty
    Huang, Tsan-Wen
    Peng, Kuo-Ti
    Huang, Kuo-Chin
    Lee, Mel S.
    Hsu, Robert Wen-Wei
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2014, 22 (12) : 2954 - 2961
  • [29] Revision total knee arthroplasty: a comparison of postoperative leg alignment after computer-assisted implantation versus the conventional technique
    Lars Perlick
    Holger Bäthis
    Carsten Perlick
    Christian Lüring
    Markus Tingart
    Joachim Grifka
    Knee Surgery, Sports Traumatology, Arthroscopy, 2005, 13 : 167 - 173
  • [30] Revision total knee arthroplasty:: a comparison of postoperative leg alignment after computer-assisted implantation versus the conventional technique
    Perlick, L
    Bäthis, H
    Perlick, C
    Lüring, C
    Tingart, M
    Grifka, J
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2005, 13 (03) : 167 - 173