Differences in component and limb alignment between computer-assisted and conventional surgery total knee arthroplasty

被引:31
|
作者
Huang, Tsan-Wen [1 ,2 ]
Peng, Kuo-Ti [1 ,2 ]
Huang, Kuo-Chin [2 ,3 ]
Lee, Mel S. [1 ,2 ]
Hsu, Robert Wen-Wei [1 ,2 ]
机构
[1] Chang Gung Mem Hosp, Div Joint Reconstruct, Dept Orthopaed Surg, Chiayi, Taiwan
[2] Chang Gung Univ, Tao Yuan, Taiwan
[3] Chang Gung Mem Hosp, Div Orthopaed Traumatol, Dept Orthopaed Surg, Chiayi, Taiwan
关键词
Total knee arthroplasty; Extra-articular deformity of the femur; Coronal femoral bowing deformity; Computer-assisted surgery; Computed tomography; EXTRAARTICULAR DEFORMITY; POSTOPERATIVE ALIGNMENT; NAVIGATION SUPPORT; AXIAL ALIGNMENT; ASIAN PATIENTS; CORONAL PLANE; REPLACEMENT; SYSTEM; INSTRUMENTATION; TRIAL;
D O I
10.1007/s00167-014-3331-8
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Marked coronal femoral bowing may bear a risk for mal-alignment of femoral component and reconstructed mechanical axis (MA) by using conventional instrumentations. The aim of this study was to investigate the usefulness of computer-assisted surgery-total knee arthroplasty (CAS-TKA) under this circumstance. We retrospectively analyzed patients with osteoarthritic knee and marked coronal femoral bowing who underwent TKA at our institution. The CAS-TKA and the conventional techniques were compared by radiographic parameters in coronal and sagittal planes, and rotational alignment of femoral component was assessed by computed tomography (CT) scans. The Hospital for Special Surgery (HSS) and International Knee Society (IKS) scores were obtained for all patients preoperatively and at the last follow-up. A total of 65 knees were enrolled in this study. Twenty-eight TKAs implanted using a CT-free navigation system, and the remaining 37 TKAs implanted using the conventional technique. CAS-TKAs were more consistent than conventional TKAs in aiding proper postoperative MA and ideal alignments of femoral component in the coronal and sagittal planes. However, CAS-TKA group was not obtained at significantly higher rates of femoral component in axial plane. At a mean follow-up of 43 months, there was no significant difference in HSS and IKS scores between the groups. Although CAS-TKA did not have superior functional outcomes in the short-term follow-up, proper coronal and sagittal alignment of femoral component and postoperative MA were obtained in patients with marked coronal femoral bowing. The long-term follow-up will be needed to clarify the eventual benefits. Retrospective comparative study, Level III.
引用
收藏
页码:2954 / 2961
页数:8
相关论文
共 50 条
  • [1] Differences in component and limb alignment between computer-assisted and conventional surgery total knee arthroplasty
    Tsan-Wen Huang
    Kuo-Ti Peng
    Kuo-Chin Huang
    Mel S. Lee
    Robert Wen-Wei Hsu
    Knee Surgery, Sports Traumatology, Arthroscopy, 2014, 22 : 2954 - 2961
  • [2] Alignment in total knee arthroplasty -: A comparison of computer-assisted surgery with the conventional technique
    Bäthis, H
    Perlick, L
    Tingart, M
    Lüring, C
    Zurakowski, D
    Grifka, J
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2004, 86B (05): : 682 - 687
  • [3] No effect of obesity on limb and component alignment after computer-assisted total knee arthroplasty
    Shetty, Gautam M.
    Mullaji, Arun B.
    Bhayde, Sagar
    Lingaraju, A. P.
    KNEE, 2014, 21 (04): : 862 - 865
  • [4] Computer-Assisted Techniques Versus Conventional Guides for Component Alignment in Total Knee Arthroplasty
    Blakeney, William G.
    Khan, Riaz J. K.
    Wall, Simon J.
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2011, 93A (15): : 1377 - 1384
  • [5] No difference in accuracy between pinless and conventional computer-assisted surgery in total knee arthroplasty
    C. Baier
    G. Maderbacher
    H. R. Springorum
    F. Zeman
    W. Fitz
    J. Schaumburger
    J. Grifka
    J. Beckmann
    Knee Surgery, Sports Traumatology, Arthroscopy, 2014, 22 : 1819 - 1826
  • [6] No difference in accuracy between pinless and conventional computer-assisted surgery in total knee arthroplasty
    Baier, C.
    Maderbacher, G.
    Springorum, H. R.
    Zeman, F.
    Fitz, W.
    Schaumburger, J.
    Grifka, J.
    Beckmann, J.
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2014, 22 (08) : 1819 - 1826
  • [7] Prosthetic alignment and sizing in computer-assisted total knee arthroplasty
    Tomoyuki Matsumoto
    Nobuhiro Tsumura
    Masahiro Kurosaka
    Hirotsugu Muratsu
    Ryosuke Kuroda
    Katsuhiko Ishimoto
    Kazuo Tsujimoto
    Ryoichi Shiba
    Shinichi Yoshiya
    International Orthopaedics, 2004, 28 : 282 - 285
  • [8] Prosthetic alignment and sizing in computer-assisted total knee arthroplasty
    Matsumoto, T
    Tsumura, N
    Kurosaka, M
    Muratsu, H
    Kuroda, R
    Ishimoto, K
    Tsujimoto, K
    Shiba, R
    Yoshiya, S
    INTERNATIONAL ORTHOPAEDICS, 2004, 28 (05) : 282 - 285
  • [9] Meta-Analysis of Alignment Outcomes in Computer-Assisted Total Knee Arthroplasty Surgery
    Mason, J. Bohannon
    Fehring, Thomas K.
    Estok, Rhonda
    Banel, Deirdre
    Fahrbach, Kyle
    JOURNAL OF ARTHROPLASTY, 2007, 22 (08): : 1097 - 1106
  • [10] Comparison of Radiographic Alignment of Image less Computer-Assisted Surgery vs Conventional Instrumentation in Primary Total Knee Arthroplasty
    Barrett, William P.
    Mason, J. Bohannon
    Moskal, Joseph T.
    Dalury, David F.
    Oliashirazi, Ali
    Fisher, David A.
    JOURNAL OF ARTHROPLASTY, 2011, 26 (08): : 1273 - 1284