Differences in component and limb alignment between computer-assisted and conventional surgery total knee arthroplasty

被引:31
|
作者
Huang, Tsan-Wen [1 ,2 ]
Peng, Kuo-Ti [1 ,2 ]
Huang, Kuo-Chin [2 ,3 ]
Lee, Mel S. [1 ,2 ]
Hsu, Robert Wen-Wei [1 ,2 ]
机构
[1] Chang Gung Mem Hosp, Div Joint Reconstruct, Dept Orthopaed Surg, Chiayi, Taiwan
[2] Chang Gung Univ, Tao Yuan, Taiwan
[3] Chang Gung Mem Hosp, Div Orthopaed Traumatol, Dept Orthopaed Surg, Chiayi, Taiwan
关键词
Total knee arthroplasty; Extra-articular deformity of the femur; Coronal femoral bowing deformity; Computer-assisted surgery; Computed tomography; EXTRAARTICULAR DEFORMITY; POSTOPERATIVE ALIGNMENT; NAVIGATION SUPPORT; AXIAL ALIGNMENT; ASIAN PATIENTS; CORONAL PLANE; REPLACEMENT; SYSTEM; INSTRUMENTATION; TRIAL;
D O I
10.1007/s00167-014-3331-8
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Marked coronal femoral bowing may bear a risk for mal-alignment of femoral component and reconstructed mechanical axis (MA) by using conventional instrumentations. The aim of this study was to investigate the usefulness of computer-assisted surgery-total knee arthroplasty (CAS-TKA) under this circumstance. We retrospectively analyzed patients with osteoarthritic knee and marked coronal femoral bowing who underwent TKA at our institution. The CAS-TKA and the conventional techniques were compared by radiographic parameters in coronal and sagittal planes, and rotational alignment of femoral component was assessed by computed tomography (CT) scans. The Hospital for Special Surgery (HSS) and International Knee Society (IKS) scores were obtained for all patients preoperatively and at the last follow-up. A total of 65 knees were enrolled in this study. Twenty-eight TKAs implanted using a CT-free navigation system, and the remaining 37 TKAs implanted using the conventional technique. CAS-TKAs were more consistent than conventional TKAs in aiding proper postoperative MA and ideal alignments of femoral component in the coronal and sagittal planes. However, CAS-TKA group was not obtained at significantly higher rates of femoral component in axial plane. At a mean follow-up of 43 months, there was no significant difference in HSS and IKS scores between the groups. Although CAS-TKA did not have superior functional outcomes in the short-term follow-up, proper coronal and sagittal alignment of femoral component and postoperative MA were obtained in patients with marked coronal femoral bowing. The long-term follow-up will be needed to clarify the eventual benefits. Retrospective comparative study, Level III.
引用
收藏
页码:2954 / 2961
页数:8
相关论文
共 50 条
  • [31] The Cost-Effectiveness of Computer-Assisted Compared with Conventional Total Knee Arthroplasty
    Tian, Yao
    Ahmed, Abdalrahman G.
    Hiredesai, Annika N.
    Huang, Lynn Wei
    Patel, Ankita M.
    Ghomrawi, Hassan M. K.
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2024, 106 (18): : 1680 - 1687
  • [32] Comparison of Computer-Assisted Navigation and Conventional Instrumentation for Bilateral Total Knee Arthroplasty
    Weng, Yi-Jan
    Hsu, Robert Wen-Wei
    Hsu, Wei-Hsiu
    JOURNAL OF ARTHROPLASTY, 2009, 24 (05): : 668 - 673
  • [33] A computed tomography based study on rotational alignment accuracy of the femoral component in total knee arthroplasty using computer-assisted orthopaedic surgery
    van der Linden-van der Zwaag, Henrica M. J.
    Bos, Janneke
    van der Heide, Huub J. L.
    Nelissen, Rob G. H. H.
    INTERNATIONAL ORTHOPAEDICS, 2011, 35 (06) : 845 - 850
  • [34] A computed tomography based study on rotational alignment accuracy of the femoral component in total knee arthroplasty using computer-assisted orthopaedic surgery
    Henrica M. J. van der Linden-van der Zwaag
    Janneke Bos
    Huub J. L. van der Heide
    Rob G. H. H. Nelissen
    International Orthopaedics, 2011, 35 : 845 - 850
  • [35] Clinical Outcomes After Computer-assisted Versus Conventional Total Knee Arthroplasty
    Xie, Chunming
    Liu, Kai
    Xiao, Luxin
    Tang, Rong
    ORTHOPEDICS, 2012, 35 (05) : E647 - E653
  • [36] The Role of Imageless Computer-Assisted Navigation During Total Knee Arthroplasty on Femoral Component Sagittal Alignment and Outcomes
    Nagarkatti, Ahana
    Strecker, Sara
    Nagarkatti, Durgesh
    Witmer, Dan
    ARTHROPLASTY TODAY, 2024, 28
  • [37] No Benefit of Robotic-Assisted over Computer-Assisted Surgery for Achieving Neutral Coronal Alignment in Total Knee Arthroplasty
    Klasan, Antonio
    Anelli-Monti, Victoria
    Huber, Stephanie
    Zacherl, Maximillian
    Hofstaetter, Jochen
    Kammerlander, Christian
    Sadoghi, Patrick
    JOURNAL OF KNEE SURGERY, 2024, 37 (01) : 8 - 13
  • [38] Computer-assisted navigation increases precision of component placement in total knee arthroplasty
    Haaker, RG
    Stockheim, M
    Kamp, M
    Proff, G
    Breitenfelder, J
    Ottersbach, A
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2005, (433) : 152 - 159
  • [39] Total knee arthroplasty with computer-assisted navigation more closely replicates normal knee biomechanics than conventional surgery
    McClelland, Jodie A.
    Webster, Kate E.
    Ramteke, Alankar A.
    Feller, Julian A.
    KNEE, 2017, 24 (03): : 651 - 656
  • [40] Computer-assisted navigation increases precision of component placement in total knee arthroplasty
    Pandher, D. S.
    Oh, K. J.
    Boaparai, R. S.
    Josan, G. S.
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2007, (454) : 281 - 282