Organ Doses and Effective Doses in Pediatric Radiography: Patient-Dose Survey in Finland

被引:33
|
作者
Kiljunen, T. [1 ]
Tietavainen, A.
Parviainen, T.
Viitala, A.
Kortesniemi, M.
机构
[1] Radiat & Nucl Safety Author, Radiat Practices Regulat, FI-00881 Helsinki, Finland
关键词
Conventional radiography; pediatrics; quality assurance; quality control; radiation safety; RADIOLOGY;
D O I
10.1080/02841850802570561
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: Use of the effective dose in diagnostic radiology permits the radiation exposure of diverse diagnostic procedures to be quantified. Fundamental knowledge of patient doses enhances the implementation of the as low as reasonably achievable (ALARA) principle. Purpose: To provide comparative information on pediatric examination protocols and patient doses in skull, sinus, chest, abdominal, and pelvic radiography examinations. Material and Methods: 24 Finnish hospitals were asked to register pediatric examination data, including patient information and examination parameters and specifications. The total number of examinations in the study was 1916 (1426 chest, 228 sinus, 96 abdominal, 94 skull, and 72 pelvic examinations). Entrance surface dose (ESD) and dose-area products (DAP) were calculated retrospectively or DAP meters were used. Organ doses and effective doses were determined using a Monte Carlo program (PCXMC). Results: There was considerable variation in examination protocols between different hospitals, indicating large variations in patient doses. Mean effective doses of different age groups ranged from 5 Sv to 14 Sv in skull and sinus examinations, from 25 Sv to 483 Sv in abdominal examinations, and from 6 Sv to 48 Sv in chest examinations. Conclusion: In chest and sinus examinations, the amount of data was extensive, allowing national pediatric diagnostic reference levels to be defined. Parameter selection in pediatric examination protocols should be harmonized in order to reduce patient doses and improve optimization.
引用
收藏
页码:114 / U16
页数:13
相关论文
共 50 条
  • [31] Effective doses to adult and pediatric patients
    Huda, W
    [J]. PEDIATRIC RADIOLOGY, 2002, 32 (04) : 272 - 279
  • [32] Effective doses to adult and pediatric patients
    Walter Huda
    [J]. Pediatric Radiology, 2002, 32 : 272 - 279
  • [33] PATIENT-SPECIFIC ORGAN DOSES FROM PEDIATRIC HEAD CT EXAMINATIONS
    Garzon, W. J.
    Aldana, D. F. A.
    Cassola, V. F.
    [J]. RADIATION PROTECTION DOSIMETRY, 2020, 191 (01) : 1 - 8
  • [34] Effective and organ doses in patient undergoing interventional neuroradiology procedures: A multicentre study
    D'Alessio, Andrea
    Strocchi, Sabina
    Dalmasso, Federico
    Cannillo, Barbara
    Matheoud, Roberta
    Ponzetti, Alex
    Aimonetto, Stefania
    Cernigliaro, Massimiliano
    Azzalin, Giulia
    Giorgianni, Andrea
    Natrella, Massimiliano
    Carriero, Alessandro
    Guzzardi, Giuseppe
    Brambilla, Marco
    [J]. PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2024, 122
  • [35] From the entrance dose to the calculation of organ doses
    Rassow, S
    [J]. RADIATION PROTECTION DOSIMETRY, 1998, 80 (1-3) : 327 - 329
  • [36] Conversion coefficients for determining organ doses in paediatric spine radiography
    Seidenbusch, Michael
    Schneider, Karl
    [J]. PEDIATRIC RADIOLOGY, 2014, 44 (04) : 434 - 456
  • [37] Conversion coefficients for determining organ doses in paediatric spine radiography
    Michael Seidenbusch
    Karl Schneider
    [J]. Pediatric Radiology, 2014, 44 : 434 - 456
  • [38] CONTEMPORARY RADIATION DOSES IN INTERVENTIONAL CARDIOLOGY: A NATIONWIDE STUDY OF PATIENT SKIN DOSES IN FINLAND
    Jarvinen, Jukka
    Sierpowska, Joanna
    Siiskonen, Teemu
    Husso, Minna
    Jarvinen, Hannu
    Kiviniemi, Tuomas
    Rissanen, Tuomas T.
    Lindholm, Carita
    Matikka, Hanna
    Larjava, Heli R. S.
    Makela, Timo J.
    Strengell, Satu
    Eskola, Markku
    Parviainen, Teuvo
    Hallinen, Elina
    Pirinen, Markku
    Kivela, Antti
    Teras, Mika
    [J]. RADIATION PROTECTION DOSIMETRY, 2020, 188 (02) : 181 - 190
  • [39] A conversion coefficient from dose-area products to effective doses for patients in intraoral radiography
    Sato K.
    Sakaino R.
    Yosue T.
    Harata Y.
    [J]. Oral Radiology, 2002, 18 (1) : 15 - 24
  • [40] Managing Pediatric CT Patient Doses
    Strauss, K.
    [J]. MEDICAL PHYSICS, 2011, 38 (06)