Prevalence and predictors of electrical storm in patients with implantable cardioverter-defibrillator

被引:85
|
作者
Arya, A [1 ]
Haghjoo, M [1 ]
Dehghani, MR [1 ]
Fazelifar, AF [1 ]
Nikoo, MH [1 ]
Bagherzadeh, A [1 ]
Sadr-Ameli, MA [1 ]
机构
[1] Iran Univ Med Sci, Rajaie Cardiovasc Med & Res Ctr, Dept Pacemaker & Electrophysiol, Tehran, Iran
来源
AMERICAN JOURNAL OF CARDIOLOGY | 2006年 / 97卷 / 03期
关键词
D O I
10.1016/j.amjcard.2005.08.058
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Identifying predictors of electrical storm in patients with implantable cardioverter-defibrillators (ICDs) could help identify those at risk and reduce the incidence of this emergency situation, which has a detrimental effect on mortality and morbidity in patients with ICDs. This retrospective study sought to determine the prevalence and predictors of electrical storm in patients with ICDs. One hundred sixty-two patients (126 men; mean age 58 +/- 13 years) who received ICDs from January 2001 to January 2005 were included in the study. Clinical, electrocardiographic, and ICD stored data and electrograms were collected and analyzed. Twenty-two patients (14%) developed electrical storm during a mean follow-up of 14.3 +/- 10 months. Using Cox multiple regression analysis, it was found that an ejection fraction < 25% (p = 0.007), QRS width >= 120 ms (p = 0.002), and a lack of adjunctive angiotensin-converting enzyme inhibitor and P-blocker therapy (both p < 0.001) were correlated with a greater probability of electrical storm. Adjunctive amiodarone and digoxin therapy, indication of ICD implantation, and age were not correlated with the occurrence of electrical storm during follow-up (all p = NS). In conclusion, electrical storm is not uncommon in patients with ICDs. Optimum medical therapy with beta blockers and angiotensin-converting enzyme inhibitors could reduce the occurrence of electrical storm, and this especially should be considered in those at greater risk for this complication (i.e., those with left ventricular ejection fractions < 25% and QRS widths >= 120ms). (c) 2006 Elsevier Inc. All rights reserved.
引用
收藏
页码:389 / 392
页数:4
相关论文
共 50 条
  • [41] Indications for implantable Cardioverter-Defibrillator
    Tebbenjohanns, J
    Niehaus, M
    Korte, T
    DEUTSCHE MEDIZINISCHE WOCHENSCHRIFT, 2002, 127 (41) : 2120 - 2124
  • [42] AUTOMATIC IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR
    EPSTEIN, AE
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1991, 102 (01): : 160 - 161
  • [43] Implantable cardioverter-defibrillator utilization
    Camm, John
    EUROPACE, 2011, 13 (03): : 448 - 448
  • [44] Erosion of an Implantable Cardioverter-Defibrillator
    Elmouchi, Darryl
    Woelfel, Alan
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2012, 59 (24) : E47 - E47
  • [45] The implantable cardioverter-defibrillator: An update
    Miller, Jared D.
    Yousuf, Omair
    Berger, Ronald D.
    TRENDS IN CARDIOVASCULAR MEDICINE, 2015, 25 (07) : 606 - 611
  • [46] Twiddling with an implantable cardioverter-defibrillator
    McCann, Conor J.
    Beelen, Roel
    Geelen, Peter
    ACTA CARDIOLOGICA, 2009, 64 (05) : 695 - 695
  • [47] Predictors of appropriate implantable cardioverter-defibrillator therapy in patients with idiopathic dilated cardiomyopathy
    Rankovic, V
    Karha, J
    Passman, R
    Kadish, AH
    Goldberger, JJ
    AMERICAN JOURNAL OF CARDIOLOGY, 2002, 89 (09): : 1072 - 1076
  • [48] Individualization of follow-up in implantable cardioverter-defibrillator patients with the help of automatic remote implantable cardioverter-defibrillator monitoring
    Neuser, H
    Schumacher, B
    Kottkamp, H
    Schmidinger, H
    Schuchert, A
    Brugada, P
    EUROPEAN HEART JOURNAL, 2004, 25 : 166 - 166
  • [50] Predictors and Proarrhythmic Consequences of Inappropriate Implantable Cardioverter-Defibrillator Therapy
    Tenma, Taro
    Yokoshiki, Hisashi
    Mizukami, Kazuya
    Mitsuyama, Hirofumi
    Watanabe, Masaya
    Sasaki, Ryo
    Maeno, Motoki
    Matsui, Yoshiro
    Tsutsui, Hiroyuki
    CIRCULATION JOURNAL, 2015, 79 (09) : 1920 - U242