Prevalence and predictors of electrical storm in patients with implantable cardioverter-defibrillator

被引:85
|
作者
Arya, A [1 ]
Haghjoo, M [1 ]
Dehghani, MR [1 ]
Fazelifar, AF [1 ]
Nikoo, MH [1 ]
Bagherzadeh, A [1 ]
Sadr-Ameli, MA [1 ]
机构
[1] Iran Univ Med Sci, Rajaie Cardiovasc Med & Res Ctr, Dept Pacemaker & Electrophysiol, Tehran, Iran
来源
AMERICAN JOURNAL OF CARDIOLOGY | 2006年 / 97卷 / 03期
关键词
D O I
10.1016/j.amjcard.2005.08.058
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Identifying predictors of electrical storm in patients with implantable cardioverter-defibrillators (ICDs) could help identify those at risk and reduce the incidence of this emergency situation, which has a detrimental effect on mortality and morbidity in patients with ICDs. This retrospective study sought to determine the prevalence and predictors of electrical storm in patients with ICDs. One hundred sixty-two patients (126 men; mean age 58 +/- 13 years) who received ICDs from January 2001 to January 2005 were included in the study. Clinical, electrocardiographic, and ICD stored data and electrograms were collected and analyzed. Twenty-two patients (14%) developed electrical storm during a mean follow-up of 14.3 +/- 10 months. Using Cox multiple regression analysis, it was found that an ejection fraction < 25% (p = 0.007), QRS width >= 120 ms (p = 0.002), and a lack of adjunctive angiotensin-converting enzyme inhibitor and P-blocker therapy (both p < 0.001) were correlated with a greater probability of electrical storm. Adjunctive amiodarone and digoxin therapy, indication of ICD implantation, and age were not correlated with the occurrence of electrical storm during follow-up (all p = NS). In conclusion, electrical storm is not uncommon in patients with ICDs. Optimum medical therapy with beta blockers and angiotensin-converting enzyme inhibitors could reduce the occurrence of electrical storm, and this especially should be considered in those at greater risk for this complication (i.e., those with left ventricular ejection fractions < 25% and QRS widths >= 120ms). (c) 2006 Elsevier Inc. All rights reserved.
引用
收藏
页码:389 / 392
页数:4
相关论文
共 50 条
  • [31] THE AUTOMATIC IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR
    DELUCA, SA
    GIRARD, M
    AMERICAN FAMILY PHYSICIAN, 1989, 39 (01) : 141 - 143
  • [32] THE AUTOMATIC IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR
    MIROWSKI, M
    REID, PR
    MOWER, MM
    WATKINS, L
    PLATIA, EV
    GRIFFITH, LSC
    JUANTEGUY, JM
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1984, 7 (03): : 534 - 540
  • [33] Implantable cardioverter-defibrillator shocks
    Raitt, Merritt H.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2008, 51 (14) : 1366 - 1368
  • [34] Development of the Implantable Cardioverter-Defibrillator
    Maron, Barry J.
    Estes, N. A. Mark
    Rowin, Ethan J.
    Maron, Martin S.
    Reynolds, Matthew R.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2023, 82 (04) : 353 - 373
  • [35] THE IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR - AN UPDATE
    MIROWSKI, M
    JOURNAL OF CARDIOVASCULAR MEDICINE, 1984, 9 (03): : 191 - &
  • [36] The subcutaneous implantable cardioverter-defibrillator
    Grace, Andrew
    CURRENT OPINION IN CARDIOLOGY, 2014, 29 (01) : 10 - 19
  • [37] A prophylactic implantable cardioverter-defibrillator?
    Brugada, P
    Wellens, F
    Andries, E
    AMERICAN JOURNAL OF CARDIOLOGY, 1996, 78 : 128 - 133
  • [38] AUTOMATIC IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR
    LATTUCA, J
    VELTRI, EP
    AMERICAN HEART JOURNAL, 1989, 118 (06) : 1359 - 1359
  • [39] Implantable cardioverter-defibrillator advances
    Lerman, RD
    Cannom, DS
    CURRENT OPINION IN CARDIOLOGY, 1996, 11 (01) : 16 - 22
  • [40] Predictors and Clinical Impact of Inappropriate Implantable Cardioverter-Defibrillator Shocks in Korean Patients
    Yang, Jeong Hoon
    Byeon, Kyeongmin
    Yim, Hye Ran
    Park, Jung Wae
    Park, Seung-Jung
    Huh, June
    Kim, June Soo
    On, Young Keun
    JOURNAL OF KOREAN MEDICAL SCIENCE, 2012, 27 (06) : 619 - 624