Prevalence and predictors of electrical storm in patients with implantable cardioverter-defibrillator

被引:85
|
作者
Arya, A [1 ]
Haghjoo, M [1 ]
Dehghani, MR [1 ]
Fazelifar, AF [1 ]
Nikoo, MH [1 ]
Bagherzadeh, A [1 ]
Sadr-Ameli, MA [1 ]
机构
[1] Iran Univ Med Sci, Rajaie Cardiovasc Med & Res Ctr, Dept Pacemaker & Electrophysiol, Tehran, Iran
来源
AMERICAN JOURNAL OF CARDIOLOGY | 2006年 / 97卷 / 03期
关键词
D O I
10.1016/j.amjcard.2005.08.058
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Identifying predictors of electrical storm in patients with implantable cardioverter-defibrillators (ICDs) could help identify those at risk and reduce the incidence of this emergency situation, which has a detrimental effect on mortality and morbidity in patients with ICDs. This retrospective study sought to determine the prevalence and predictors of electrical storm in patients with ICDs. One hundred sixty-two patients (126 men; mean age 58 +/- 13 years) who received ICDs from January 2001 to January 2005 were included in the study. Clinical, electrocardiographic, and ICD stored data and electrograms were collected and analyzed. Twenty-two patients (14%) developed electrical storm during a mean follow-up of 14.3 +/- 10 months. Using Cox multiple regression analysis, it was found that an ejection fraction < 25% (p = 0.007), QRS width >= 120 ms (p = 0.002), and a lack of adjunctive angiotensin-converting enzyme inhibitor and P-blocker therapy (both p < 0.001) were correlated with a greater probability of electrical storm. Adjunctive amiodarone and digoxin therapy, indication of ICD implantation, and age were not correlated with the occurrence of electrical storm during follow-up (all p = NS). In conclusion, electrical storm is not uncommon in patients with ICDs. Optimum medical therapy with beta blockers and angiotensin-converting enzyme inhibitors could reduce the occurrence of electrical storm, and this especially should be considered in those at greater risk for this complication (i.e., those with left ventricular ejection fractions < 25% and QRS widths >= 120ms). (c) 2006 Elsevier Inc. All rights reserved.
引用
收藏
页码:389 / 392
页数:4
相关论文
共 50 条
  • [1] Electrical storm in patients with implantable cardioverter-defibrillator
    Mitrega, Katarzyna
    Sredniawa, Beata
    Kowalski, Oskar
    Lenarczyk, Radoslaw
    Musialik-Lydka, Agata
    Kalarus, Zbigniew
    KARDIOLOGIA POLSKA, 2013, 71 (02) : 198 - 201
  • [2] Electrical storm in patients with implantable cardioverter-defibrillator
    Fernandez, G.
    Maid, G. M.
    Albaca, G. A.
    Constantin, I. C.
    EUROPEAN HEART JOURNAL, 2018, 39 : 215 - 215
  • [3] Electrical Storm in patients with an Implantable Cardioverter-Defibrillator
    Leibundgut, G.
    Osswald, S.
    Sticherling, C.
    Kuehne, M.
    Schaer, B.
    EUROPEAN HEART JOURNAL, 2009, 30 : 556 - 556
  • [4] Propranolol Versus Metoprolol for Treatment of Electrical Storm in Patients With Implantable Cardioverter-Defibrillator
    Chatzidou, Sofia
    Kontogiannis, Christos
    Tsilimigras, Diamantis I.
    Georgiopoulos, Georgios
    Kosmopoulos, Marinos
    Papadopoulou, Elektra
    Vasilopoulos, Georgios
    Rokas, Stylianos
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2018, 71 (17) : 1897 - 1906
  • [5] Incidence of and predictors for appropriate implantable cardioverter-defibrillator therapy in patients with a secondary preventive implantable cardioverter-defibrillator indication
    Schaer, Beat
    Kuehne, Michael
    Reichlin, Tobias
    Osswald, Stefan
    Sticherling, Christian
    EUROPACE, 2016, 18 (02): : 227 - 231
  • [6] Predictors of panic for patients with implantable cardioverter-defibrillator (ICD)
    Lang, S.
    Becker, R.
    Herzog, W.
    Hartmann, M.
    Loewe, B.
    PSYCHOTHERAPIE PSYCHOSOMATIK MEDIZINISCHE PSYCHOLOGIE, 2008, 58 (02) : 95 - 95
  • [7] Prevalence, predictors, and outcomes of advance directives in implantable cardioverter-defibrillator recipients
    Merchant, Faisal M.
    Binney, Zachary
    Patel, Adarsh
    Li, Jennifer
    Peddareddy, Lakshmi P.
    El-Chami, Mikhael F.
    Leon, Angel R.
    Quest, Tammie
    HEART RHYTHM, 2017, 14 (06) : 830 - 836
  • [8] Predictors of Implantable Cardioverter-Defibrillator Use in Patients with Ischemic Cardiomyopathy
    Kelly, Ryan
    Buth, Karen J.
    Heimrath, Olivier
    Basta, Magdy
    Legare, Jean-Francois
    OPEN CARDIOVASCULAR MEDICINE JOURNAL, 2010, 4 : 206 - 213
  • [9] PREDICTORS OF INAPPROPRIATE IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR DISCHARGES
    Catanzaro, John N.
    Makaryus, Amgad
    Makaryus, John
    Sison, Cristina
    Vavasis, Christos
    Donaldson, David
    Altman, Erik
    Beldner, Stuart
    Jadonath, Ram
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2011, 57 (14) : E172 - E172
  • [10] Electrical storm in patients with biventricular implantable cardioverter defibrillator: Incidence, predictors, and prognostic implications
    Gasparini, Maurizio
    Lunati, Maurizio
    Landolina, Maurizio
    Santini, Massirno
    Padeletti, Luigi
    Perego, Gianni
    Vincenti, Antonio
    Curnis, Antonio
    Carboni, Angelo
    Denaro, Alessandra
    Spotti, Alessia K.
    Grarnmatico, Andrea
    Regoli, Francois
    Boriani, Giuseppe
    AMERICAN HEART JOURNAL, 2008, 156 (05) : 847 - 854