Objective characterization of airway dimensions using image processing

被引:10
|
作者
Pepper, Victoria K. [1 ,2 ]
Francom, Christian [3 ,4 ]
Best, Cameron A. [1 ]
Onwuka, Ekene [1 ,5 ]
King, Nakesha [1 ,5 ]
Heuer, Eric [1 ]
Mahler, Nathan [1 ]
Grischkan, Jonathan [3 ,4 ]
Breuer, Christopher K. [1 ,2 ]
Chiang, Tendy [1 ,3 ,4 ]
机构
[1] Nationwide Childrens Hosp, Res Inst, Tissue Engn & Surg Res, 700 Childrens Dr,Suite WB4154, Columbus, OH 43205 USA
[2] Nationwide Childrens Hosp, Dept Pediat Surg, 700 Childrens Dr, Columbus, OH 43205 USA
[3] Ohio State Univ, Dept Otolaryngol Head & Neck Surg, 915 Olentangy River Rd 4000, Columbus, OH 43212 USA
[4] Nationwide Childrens Hosp, Dept Pediat Otolaryngol Head & Neck Surg, 700 Childrens Dr, Columbus, OH 43205 USA
[5] Ohio State Univ, Wexner Med Ctr, Dept Surg, 395 W 12th Ave,Suite 670, Columbus, OH 43210 USA
基金
美国国家科学基金会;
关键词
Airway reconstruction; Quantitative endoscopy; Airway management; Airway stenosis; Image processing;
D O I
10.1016/j.ijporl.2016.10.004
中图分类号
R76 [耳鼻咽喉科学];
学科分类号
100213 ;
摘要
Objectives: With the evolution of medical and surgical management for pediatric airway disorders, the development of easily translated techniques of measuring airway dimensions can improve the quantification of outcomes of these interventions. We have developed a technique that improves the ability to characterize endoscopic airway dimensions using common bronchoscopic equipment and an open source image-processing platform. Methods: We validated our technique of Endoscopic Airway Measurement (EAM) using optical instruments in simulation tracheas. We then evaluated EAM in a large animal model (Ovis aries, n = 5), comparing tracheal dimensions obtained with EAM to measurements obtained via 3-D fluoroscopic reconstruction. The animal then underwent resection of the measured segment, and direct measurement of this segment was performed and compared to radiographic measurements and those obtained using EAM. Results: The simulation tracheas had a direct measurement of 13.6, 18.5, and 24.2 mm in diameter. The mean difference of diameter in simulation tracheas between direct measurements and measurements obtained using EAM was 0.70 +/- 0.57 mm. The excised ovine tracheas had an average diameter of 18.54 +/- 0.68 mm. The percent difference in diameter obtained from EAM and from 3-D fluoroscopic reconstruction when compared to measurement of the excised tracheal segment was 4.98 +/- 2.43% and 10.74 +/- 4.07% respectively. Comparison of these three measurements (EAM, measurement of resected trachea, 3-D fluoroscopic reconstruction) with repeated measures ANOVA demonstrated no statistical significance. Conclusions: Endoscopic airway measurement (EAM) provides equivalent measurements of the airway with the improved versatility of measuring non-circular and multi-level dimensions. Using optical bronchoscopic instruments and open-source image-processing software, our data supports preclinical and clinical translation of an accessible technique to provide objective quantification of airway diameter. (C) 2016 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:108 / 112
页数:5
相关论文
共 50 条
  • [41] ANALOG IMAGE-PROCESSING IN 2 DIMENSIONS BY OMNIDIRECTIONAL SCANNING
    GREGG, EC
    JOURNAL OF NUCLEAR MEDICINE, 1975, 16 (07) : 685 - 685
  • [42] ANALOG IMAGE-PROCESSING IN 2 DIMENSIONS BY OMNIDIRECTIONAL SCANNING
    NOHARA, N
    TOMITANI, T
    TANAKA, E
    JOURNAL OF NUCLEAR MEDICINE, 1974, 15 (10) : 844 - 847
  • [43] IMAGE SEQUENCE PROCESSING - RELATIONSHIPS BETWEEN TEMPORAL AND SPATIAL DIMENSIONS
    HUANG, TS
    PROCEEDINGS OF THE SOCIETY OF PHOTO-OPTICAL INSTRUMENTATION ENGINEERS, 1984, 373 : 141 - 144
  • [44] IMAGE-PROCESSING FOR MATERIALS CHARACTERIZATION
    KRAKOW, W
    JOURNAL OF METALS, 1982, 35 (12): : A42 - A42
  • [45] Objective analysis of typographies by image processing based on the optotypes' guidelines
    Abril, Hector C.
    Tapias, Montserrat
    Torrents, Aurora
    OPTICA PURA Y APLICADA, 2013, 46 (01): : 73 - 82
  • [46] Instrumentation and objective evaluation of flammability of textiles by video image processing
    Khandual, Asimananda
    Grover, Tarun
    Luximon, Yan
    Rout, Nibedita
    Nayak, Rajkishore
    JOURNAL OF THE TEXTILE INSTITUTE, 2020, 111 (08) : 1176 - 1183
  • [47] Objective assessment of wrinkled fabrics by optical and digital image processing
    Abril, Hector C.
    Valencia, Edison
    Millan, Maria S.
    RIAO/OPTILAS 2007, 2008, 992 : 1045 - 1050
  • [48] Overview of the applications of multiple objective optimization methods in image processing
    Coll. of Mechatronic Engineering and Automation, National Univ. of Defense Technology, Changsha 410073, China
    Xi Tong Cheng Yu Dian Zi Ji Shu/Syst Eng Electron, 2008, 9 (1774-1781):
  • [49] Substrate characterization for ventricular tachycardia ablation using a new image processing service
    Florian Spies
    Michael Kühne
    Christian Sticherling
    Sven Knecht
    Clinical Research in Cardiology, 2021, 110 : 913 - 915
  • [50] Characterization of Breast Microcalcifications Using a New Ultrasound Image-Processing Technique
    Machado, Priscilla
    Eisenbrey, John R.
    Stanczak, Maria
    Cavanaugh, Barbara C.
    Zorn, Lisa M.
    Forsberg, Flemming
    JOURNAL OF ULTRASOUND IN MEDICINE, 2019, 38 (07) : 1733 - 1738