Objective characterization of airway dimensions using image processing

被引:10
|
作者
Pepper, Victoria K. [1 ,2 ]
Francom, Christian [3 ,4 ]
Best, Cameron A. [1 ]
Onwuka, Ekene [1 ,5 ]
King, Nakesha [1 ,5 ]
Heuer, Eric [1 ]
Mahler, Nathan [1 ]
Grischkan, Jonathan [3 ,4 ]
Breuer, Christopher K. [1 ,2 ]
Chiang, Tendy [1 ,3 ,4 ]
机构
[1] Nationwide Childrens Hosp, Res Inst, Tissue Engn & Surg Res, 700 Childrens Dr,Suite WB4154, Columbus, OH 43205 USA
[2] Nationwide Childrens Hosp, Dept Pediat Surg, 700 Childrens Dr, Columbus, OH 43205 USA
[3] Ohio State Univ, Dept Otolaryngol Head & Neck Surg, 915 Olentangy River Rd 4000, Columbus, OH 43212 USA
[4] Nationwide Childrens Hosp, Dept Pediat Otolaryngol Head & Neck Surg, 700 Childrens Dr, Columbus, OH 43205 USA
[5] Ohio State Univ, Wexner Med Ctr, Dept Surg, 395 W 12th Ave,Suite 670, Columbus, OH 43210 USA
基金
美国国家科学基金会;
关键词
Airway reconstruction; Quantitative endoscopy; Airway management; Airway stenosis; Image processing;
D O I
10.1016/j.ijporl.2016.10.004
中图分类号
R76 [耳鼻咽喉科学];
学科分类号
100213 ;
摘要
Objectives: With the evolution of medical and surgical management for pediatric airway disorders, the development of easily translated techniques of measuring airway dimensions can improve the quantification of outcomes of these interventions. We have developed a technique that improves the ability to characterize endoscopic airway dimensions using common bronchoscopic equipment and an open source image-processing platform. Methods: We validated our technique of Endoscopic Airway Measurement (EAM) using optical instruments in simulation tracheas. We then evaluated EAM in a large animal model (Ovis aries, n = 5), comparing tracheal dimensions obtained with EAM to measurements obtained via 3-D fluoroscopic reconstruction. The animal then underwent resection of the measured segment, and direct measurement of this segment was performed and compared to radiographic measurements and those obtained using EAM. Results: The simulation tracheas had a direct measurement of 13.6, 18.5, and 24.2 mm in diameter. The mean difference of diameter in simulation tracheas between direct measurements and measurements obtained using EAM was 0.70 +/- 0.57 mm. The excised ovine tracheas had an average diameter of 18.54 +/- 0.68 mm. The percent difference in diameter obtained from EAM and from 3-D fluoroscopic reconstruction when compared to measurement of the excised tracheal segment was 4.98 +/- 2.43% and 10.74 +/- 4.07% respectively. Comparison of these three measurements (EAM, measurement of resected trachea, 3-D fluoroscopic reconstruction) with repeated measures ANOVA demonstrated no statistical significance. Conclusions: Endoscopic airway measurement (EAM) provides equivalent measurements of the airway with the improved versatility of measuring non-circular and multi-level dimensions. Using optical bronchoscopic instruments and open-source image-processing software, our data supports preclinical and clinical translation of an accessible technique to provide objective quantification of airway diameter. (C) 2016 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:108 / 112
页数:5
相关论文
共 50 条
  • [21] Detection and Characterization of Antinuclear Antibody using Fluorescence Image Processing
    Khan, Munezza Ata
    Hassan, M.
    Malik, Saadia
    Islam, Saima
    Ansari, Umar
    Gilani, Omar
    2014 INTERNATIONAL CONFERENCE ON ROBOTICS AND EMERGING ALLIED TECHNOLOGIES IN ENGINEERING (ICREATE), 2014, : 87 - 90
  • [22] Measurement of Critical Dimensions of Cold Roll Formed Sections Using Digital Image Processing
    Williams, Ian
    Shirvani, Bez
    Mourier, Jean Michael
    SHEET METAL 2011, 2011, 473 : 949 - +
  • [23] Image processing for particle characterization
    Nazar, AM
    Silva, FA
    Ammann, JJ
    MATERIALS CHARACTERIZATION, 1996, 36 (4-5) : 165 - 173
  • [24] Processing Digital Image for Measurement of Crack Dimensions in Concrete
    Barkavi, T.
    Natarajan, C.
    CIVIL ENGINEERING INFRASTRUCTURES JOURNAL-CEIJ, 2019, 52 (01): : 11 - 22
  • [25] Quaternions in Signal and Image Processing: A comprehensive and objective overview
    Miron, Sebastian
    Flamant, Julien
    Le Bihan, Nicolas
    Chainais, Pierre
    Brie, David
    IEEE SIGNAL PROCESSING MAGAZINE, 2023, 40 (06) : 26 - 40
  • [26] Objective evaluation of singeing efficiency by digital image processing
    Khandual, A.
    Baciu, G.
    Luximon, A.
    Rout, N.
    JOURNAL OF THE TEXTILE INSTITUTE, 2016, 107 (02) : 273 - 281
  • [27] Digital image processing of Schmidt objective prism spectra
    Ferrin, I
    Fuenmayor, F
    Hernández, J
    EXPERIMENTAL ASTRONOMY, 1999, 9 (04) : 205 - 211
  • [28] Digital Image Processing of Schmidt Objective Prism Spectra
    Ignacio Ferrin
    Francisco Fuenmayor
    Jesús Hernández
    Experimental Astronomy, 1999, 9 : 205 - 211
  • [29] MICROSTRUCTURAL CHARACTERIZATION OF STRUCTURAL CERAMICS USING IMAGE-PROCESSING AND ANALYSIS
    HEFTER, J
    HECKER, A
    MAHONEY, FM
    HARRIS, JE
    JOURNAL OF THE AMERICAN CERAMIC SOCIETY, 1993, 76 (06) : 1551 - 1557
  • [30] Characterization of electrothermal micro-actuator using image processing algorithm
    Ulkir, Osman
    Ertugrul, Ishak
    Akkus, Nihat
    JOURNAL OF THE FACULTY OF ENGINEERING AND ARCHITECTURE OF GAZI UNIVERSITY, 2021, 36 (02): : 1159 - 1170