Objective characterization of airway dimensions using image processing

被引:10
|
作者
Pepper, Victoria K. [1 ,2 ]
Francom, Christian [3 ,4 ]
Best, Cameron A. [1 ]
Onwuka, Ekene [1 ,5 ]
King, Nakesha [1 ,5 ]
Heuer, Eric [1 ]
Mahler, Nathan [1 ]
Grischkan, Jonathan [3 ,4 ]
Breuer, Christopher K. [1 ,2 ]
Chiang, Tendy [1 ,3 ,4 ]
机构
[1] Nationwide Childrens Hosp, Res Inst, Tissue Engn & Surg Res, 700 Childrens Dr,Suite WB4154, Columbus, OH 43205 USA
[2] Nationwide Childrens Hosp, Dept Pediat Surg, 700 Childrens Dr, Columbus, OH 43205 USA
[3] Ohio State Univ, Dept Otolaryngol Head & Neck Surg, 915 Olentangy River Rd 4000, Columbus, OH 43212 USA
[4] Nationwide Childrens Hosp, Dept Pediat Otolaryngol Head & Neck Surg, 700 Childrens Dr, Columbus, OH 43205 USA
[5] Ohio State Univ, Wexner Med Ctr, Dept Surg, 395 W 12th Ave,Suite 670, Columbus, OH 43210 USA
基金
美国国家科学基金会;
关键词
Airway reconstruction; Quantitative endoscopy; Airway management; Airway stenosis; Image processing;
D O I
10.1016/j.ijporl.2016.10.004
中图分类号
R76 [耳鼻咽喉科学];
学科分类号
100213 ;
摘要
Objectives: With the evolution of medical and surgical management for pediatric airway disorders, the development of easily translated techniques of measuring airway dimensions can improve the quantification of outcomes of these interventions. We have developed a technique that improves the ability to characterize endoscopic airway dimensions using common bronchoscopic equipment and an open source image-processing platform. Methods: We validated our technique of Endoscopic Airway Measurement (EAM) using optical instruments in simulation tracheas. We then evaluated EAM in a large animal model (Ovis aries, n = 5), comparing tracheal dimensions obtained with EAM to measurements obtained via 3-D fluoroscopic reconstruction. The animal then underwent resection of the measured segment, and direct measurement of this segment was performed and compared to radiographic measurements and those obtained using EAM. Results: The simulation tracheas had a direct measurement of 13.6, 18.5, and 24.2 mm in diameter. The mean difference of diameter in simulation tracheas between direct measurements and measurements obtained using EAM was 0.70 +/- 0.57 mm. The excised ovine tracheas had an average diameter of 18.54 +/- 0.68 mm. The percent difference in diameter obtained from EAM and from 3-D fluoroscopic reconstruction when compared to measurement of the excised tracheal segment was 4.98 +/- 2.43% and 10.74 +/- 4.07% respectively. Comparison of these three measurements (EAM, measurement of resected trachea, 3-D fluoroscopic reconstruction) with repeated measures ANOVA demonstrated no statistical significance. Conclusions: Endoscopic airway measurement (EAM) provides equivalent measurements of the airway with the improved versatility of measuring non-circular and multi-level dimensions. Using optical bronchoscopic instruments and open-source image-processing software, our data supports preclinical and clinical translation of an accessible technique to provide objective quantification of airway diameter. (C) 2016 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:108 / 112
页数:5
相关论文
共 50 条
  • [1] Objective measurement of nasal airway dimensions using acoustic rhinometry: methodological and clinical aspects
    Hilberg, O
    ALLERGY, 2002, 57 : 5 - 39
  • [2] Objective measurement of nasal airway dimensions using acoustic rhinometry: methodological and clinical aspects
    Hilberg, O
    ALLERGY, 2002, 57 : 5 - 39
  • [3] Objective measurement of fabric appearance using digital image processing
    Behera, B. K.
    Mishra, R.
    JOURNAL OF THE TEXTILE INSTITUTE, 2006, 97 (02) : 147 - 153
  • [4] Characterization of artificial muscles using image processing
    Berenguer Vidal, Rafael
    Verdu Monedero, Rafael
    Morales Sanchez, Juan
    Larrey Ruiz, Jorge
    NATURE INSPIRED PROBLEM-SOLVING METHODS IN KNOWLEDGE ENGINEERING, PT 2, PROCEEDINGS, 2007, 4528 : 142 - +
  • [5] Soil Classification & Characterization Using Image Processing
    Sharma, Hement Kumar
    Kumar, Shiv
    PROCEEDINGS OF THE 2ND INTERNATIONAL CONFERENCE ON COMPUTING METHODOLOGIES AND COMMUNICATION (ICCMC 2018), 2018, : 885 - 890
  • [6] Airway tapering: an objective image biomarker for bronchiectasis
    Kuo, Wieying
    Perez-Rovira, Adria
    Tiddens, Harm
    de Bruijne, Marleen
    EUROPEAN RADIOLOGY, 2020, 30 (05) : 2703 - 2711
  • [7] Airway tapering: an objective image biomarker for bronchiectasis
    Wieying Kuo
    Adria Perez-Rovira
    Harm Tiddens
    Marleen de Bruijne
    European Radiology, 2020, 30 : 2703 - 2711
  • [8] Objective measurement of water repellency of fabric using image analysis (I) - Methodology of image processing
    Jeong, YJ
    Jang, JH
    FIBERS AND POLYMERS, 2005, 6 (02) : 162 - 168
  • [9] Objective measurement of water repellency of fabric using image analysis (I)Methodology of image processing
    Young Jin Jeong
    Jinho Jang
    Fibers and Polymers, 2005, 6 : 162 - 168
  • [10] Characterization of blood samples using image processing techniques
    Ferraz, Ana
    Carvalho, Vitor
    Soares, Filomena
    Leao, Celina P.
    SENSORS AND ACTUATORS A-PHYSICAL, 2011, 172 (01) : 308 - 314