Feasibility, Safety, and Efficacy of Accurate Uterine Fibroid Ablation Using Magnetic Resonance Imaging-Guided High-Intensity Focused Ultrasound With Shot Sonication

被引:25
|
作者
Xu, Yonghua [1 ,2 ,3 ,4 ]
Fu, Zhongxiang [3 ,4 ]
Yang, Lixia [3 ,4 ]
Huang, Zili [3 ,4 ]
Chen, Wen-Zhi [1 ,2 ]
Wang, Zhibiao [1 ,2 ]
机构
[1] Chongqing Med Univ, Coll Biomed Engn, Chongqing 400016, Peoples R China
[2] Chongqing Med Univ, Affiliated Hosp 1, Chongqing 400016, Peoples R China
[3] Chinese Acad Sci, Xuhui Cent Hosp Shanghai, Shanghai, Peoples R China
[4] Chinese Acad Sci, Shanghai Clin Ctr, Shanghai, Peoples R China
关键词
ablation; magnetic resonance imaging; magnetic resonance imaging-guided high-intensity focused ultrasound; nonperfused volume; uterine fibroid; ARTERY EMBOLIZATION; CLINICAL-OUTCOMES; SURGERY; LEIOMYOMAS; THERAPY;
D O I
10.7863/ultra.14.12080
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
The aim of this study was to investigate the feasibility, safety, and efficacy of uterine fibroid treatment using magnetic resonance imaging (MRI)-guided high-intensity focused ultrasound (US) with shot sonication for accurate ablation. Forty-three patients with 51 symptomatic uterine fibroids were treated with MRI-guided high-intensity focused US with shot sonication, which was a small acoustic focus of higher intensity with a shorter time (2 seconds) of US exposure and a shorter cooling time (2-3 seconds). The treatment efficacy and adverse events were analyzed, and the changes in the severity of symptoms and the reduction in fibroid volume were assessed 3 and 6 months after the procedure. All patients were successfully treated in a single session, without major complications, and the mean nonperfused volume ratio +/- SD was 84.3% +/- 15.7% (range, 33.8%-100%). Complete ablation was achieved in 13 T2-hypointense fibroids from 10 patients, and partial ablation was achieved in 38 fibroids from 33 patients. The overall mean treatment time was 135.0 +/- 50.9 minutes (2.2 +/- 0.8 hours). The transformed symptom severity scores and mean fibroid volumes decreased significantly after treatment (P < .05). In conclusion, MRI-guided high-intensity focused US with shot sonication is a feasible, safe, and effective technique for ablation of uterine fibroids and complete ablation of T2-hypointense fibroids.
引用
收藏
页码:2293 / 2303
页数:11
相关论文
共 50 条
  • [41] Renal ablation using magnetic resonance-guided high intensity focused ultrasound: Magnetic resonance imaging and histopathology assessment
    Saeed, Maythem
    Krug, Roland
    Do, Loi
    Hetts, Steven W.
    Wilson, Mark W.
    WORLD JOURNAL OF RADIOLOGY, 2016, 8 (03): : 298 - 307
  • [42] A feasibility analysis of the ArcBlate MR-guided high-intensity focused ultrasound system for the ablation of uterine fibroids
    Wang, Chin-Jung
    Lin, Gigin
    Huang, Yi-Ting
    Weng, Cindy Hsuan
    Wu, Kai-Yun
    Su, Yu-Ying
    Lin, Yu-Shan
    Mak, Kit-Sum
    ABDOMINAL RADIOLOGY, 2021, 46 (11) : 5307 - 5315
  • [43] Ultrasound-guided high-intensity focused ultrasound ablation for treating uterine arteriovenous malformation
    Yan, X.
    Zhao, C.
    Tian, C.
    Wen, S.
    He, X.
    Zhou, Y.
    BJOG-AN INTERNATIONAL JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 2017, 124 : 93 - 96
  • [44] Efficacy of magnetic resonance-guided high intensity focused ultrasound for the ablation of breast cancer
    de Maar, Josanne Sophia
    Deckers, Roel
    Bartels, Lambertus Wilhelmus
    van Dalen, Thijs
    van Gorp, Joost
    van Diest, Paul J.
    Witkamp, Arjen J.
    Vaessen, H. H. B.
    Braat, Maria NicoleGerardineJohanna Aleida
    Moonen, Chrit
    CANCER RESEARCH, 2020, 80 (04)
  • [45] Feasibility and efficacy of ultrasound-guided high-intensity focused ultrasound of breast fibroadenoma
    Liang, Mengdi
    Zhang, Zhizheng
    Zhang, Cai
    Chen, Rui
    Xiao, Yao
    Li, Zi
    Li, Tao
    Liu, Yuelin
    Ling, Lijun
    Xie, Hui
    Chen, Lin
    Liu, Xiaoan
    Wang, Shui
    Xia, Tiansong
    INTERNATIONAL JOURNAL OF HYPERTHERMIA, 2023, 40 (01)
  • [46] Long-term Efficacy of Fibroid Devascularization with Ultrasound-Guided High-Intensity Focused Ultrasound
    Zhou, Yun
    Chen, Ping
    Ji, Xiang
    Sun, Taotao
    Li, Yuhong
    Yuan, Jiangjing
    Chen, Youguo
    Xiong, Yuanhuan
    Wang, Yudong
    ACADEMIC RADIOLOGY, 2024, 31 (05) : 1931 - 1939
  • [47] Evaluation Value of Intravoxel Incoherent Motion Diffusion-Weighted Imaging on Early Efficacy of Magnetic Resonance-Guided High-Intensity Focused Ultrasound Ablation for Uterine Adenomyoma
    Tang N.
    Gu J.
    Yin X.
    Yu R.
    Xu Y.
    Li X.
    Wang H.
    Journal of Shanghai Jiaotong University (Science), 2022, 27 (02): : 226 - 230
  • [48] Early evaluation of magnetic resonance imaging guided focused ultrasound sonication in the treatment of uterine fibroids
    Himabindu, Y.
    Sriharibabu, M.
    Nyapathy, Vinay
    Mishra, Anindita
    INDIAN JOURNAL OF MEDICAL RESEARCH, 2014, 139 : 267 - 272
  • [49] Exploring the Diagnostic Performance of Magnetic Resonance Imaging in Ultrasound-Guided High-Intensity Focused Ultrasound Ablation for Abdominal Wall Endometriosis
    Hu, Shangying
    Liu, Yuhang
    Chen, Rongsheng
    Xiao, Zhibo
    FRONTIERS IN PHYSIOLOGY, 2022, 13
  • [50] Volumetric feedback ablation of uterine fibroids using magnetic resonance-guided high intensity focused ultrasound therapy
    M. J. Voogt
    H. Trillaud
    Y. S. Kim
    W. P. Th. M. Mali
    J. Barkhausen
    L. W. Bartels
    R. Deckers
    N. Frulio
    H. Rhim
    H. K. Lim
    T. Eckey
    H. J. Nieminen
    C. Mougenot
    B. Keserci
    J. Soini
    T. Vaara
    M. O. Köhler
    S. Sokka
    Maurice A. A. J. van den Bosch
    European Radiology, 2012, 22 : 411 - 417