Feasibility, Safety, and Efficacy of Accurate Uterine Fibroid Ablation Using Magnetic Resonance Imaging-Guided High-Intensity Focused Ultrasound With Shot Sonication

被引:25
|
作者
Xu, Yonghua [1 ,2 ,3 ,4 ]
Fu, Zhongxiang [3 ,4 ]
Yang, Lixia [3 ,4 ]
Huang, Zili [3 ,4 ]
Chen, Wen-Zhi [1 ,2 ]
Wang, Zhibiao [1 ,2 ]
机构
[1] Chongqing Med Univ, Coll Biomed Engn, Chongqing 400016, Peoples R China
[2] Chongqing Med Univ, Affiliated Hosp 1, Chongqing 400016, Peoples R China
[3] Chinese Acad Sci, Xuhui Cent Hosp Shanghai, Shanghai, Peoples R China
[4] Chinese Acad Sci, Shanghai Clin Ctr, Shanghai, Peoples R China
关键词
ablation; magnetic resonance imaging; magnetic resonance imaging-guided high-intensity focused ultrasound; nonperfused volume; uterine fibroid; ARTERY EMBOLIZATION; CLINICAL-OUTCOMES; SURGERY; LEIOMYOMAS; THERAPY;
D O I
10.7863/ultra.14.12080
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
The aim of this study was to investigate the feasibility, safety, and efficacy of uterine fibroid treatment using magnetic resonance imaging (MRI)-guided high-intensity focused ultrasound (US) with shot sonication for accurate ablation. Forty-three patients with 51 symptomatic uterine fibroids were treated with MRI-guided high-intensity focused US with shot sonication, which was a small acoustic focus of higher intensity with a shorter time (2 seconds) of US exposure and a shorter cooling time (2-3 seconds). The treatment efficacy and adverse events were analyzed, and the changes in the severity of symptoms and the reduction in fibroid volume were assessed 3 and 6 months after the procedure. All patients were successfully treated in a single session, without major complications, and the mean nonperfused volume ratio +/- SD was 84.3% +/- 15.7% (range, 33.8%-100%). Complete ablation was achieved in 13 T2-hypointense fibroids from 10 patients, and partial ablation was achieved in 38 fibroids from 33 patients. The overall mean treatment time was 135.0 +/- 50.9 minutes (2.2 +/- 0.8 hours). The transformed symptom severity scores and mean fibroid volumes decreased significantly after treatment (P < .05). In conclusion, MRI-guided high-intensity focused US with shot sonication is a feasible, safe, and effective technique for ablation of uterine fibroids and complete ablation of T2-hypointense fibroids.
引用
收藏
页码:2293 / 2303
页数:11
相关论文
共 50 条
  • [21] Diagnosis of uterine leiomyosarcoma 5 years after magnetic-resonance-guided high-intensity focused ultrasound treatment of fibroid
    Ciccarone, F.
    Biscione, A.
    Lorusso, D.
    Zannoni, G. F.
    Cina, A.
    Ferrandina, G.
    Scambia, G.
    Testa, A. C.
    ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2022, 59 (01) : 125 - 126
  • [22] Efficacy and Safety of Ultrasound-Guided High-Intensity Focused Ultrasound Ablation in Women With Multiple Uterine Fibroids: An Exploratory Study
    Shi, Liye
    Zhang, Rongsen
    Tao, Siqi
    Yuan, Xiaorui
    Zhang, Jun
    Wang, Beibei
    Xiang, Mengting
    Ren, Zhen
    Cai, Haiyi
    Fu, Chun
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2023, 49 (11): : 2378 - 2387
  • [23] Targeted Vessel Ablation for More Efficient Magnetic Resonance-Guided High-Intensity Focused Ultrasound Ablation of Uterine Fibroids
    Marianne J. Voogt
    Marijn van Stralen
    Marlijne E. Ikink
    Roel Deckers
    Koen L. Vincken
    Lambertus W. Bartels
    Willem P. Th. M. Mali
    Maurice A. A. J. van den Bosch
    CardioVascular and Interventional Radiology, 2012, 35 : 1205 - 1210
  • [24] Targeted Vessel Ablation for More Efficient Magnetic Resonance-Guided High-Intensity Focused Ultrasound Ablation of Uterine Fibroids
    Voogt, Marianne J.
    van Stralen, Marijn
    Ikink, Marlijne E.
    Deckers, Roel
    Vincken, Koen L.
    Bartels, Lambertus W.
    Mali, Willem P. Th M.
    van den Bosch, Maurice A. A. J.
    CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2012, 35 (05) : 1205 - 1210
  • [25] Successful Magnetic Resonance Imaging-Guided Focused Ultrasound Surgery for Recurrent Uterine Fibroid Previously Treated with Uterine Artery Embolization
    Yoon, Sang-Wook
    Kim, Kyoung Ah
    Kim, Sang Heum
    Lee, Jong Tae
    OBSTETRICS AND GYNECOLOGY INTERNATIONAL, 2010, 2010
  • [26] Feasibility of magnetic resonance imaging-guided high intensity focused ultrasound therapy for ablating uterine fibroids in patients with bowel lies anterior to uterus
    Zhang, Lian
    Chen, Wen-Zhi
    Liu, Yin-Jiang
    Hu, Xiao
    Zhou, Kun
    Chen, Li
    Peng, Song
    Zhu, Hui
    Zou, Hui-Ling
    Bai, Jin
    Wang, Zhi-Biao
    EUROPEAN JOURNAL OF RADIOLOGY, 2010, 73 (02) : 396 - 403
  • [27] SAFETY AND EFFICACY OF ULTRASOUND-GUIDED HIGH-INTENSITY FOCUSED ULTRASOUND TREATMENT FOR UTERINE FIBROIDS AND ADENOMYOSIS
    Lee, Jae-Seong
    Hong, Gi-Youn
    Lee, Kye-Hwa
    Song, Jung-Hwa
    Kim, Tae-Eung
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2019, 45 (12): : 3214 - 3221
  • [28] Efficacy and safety of ultrasound-guided high-intensity focused ultrasound for uterine fibroids: a preliminary experience
    Cheung, Vincent Y. T.
    Lam, Tina P. W.
    Jenkins, Caroline R.
    Lam, S. W.
    Cheung, Grace K., I
    Chan, Selina S. Y.
    Choi, W. K.
    JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 2019, 39 (06) : 833 - 839
  • [29] A novel scoring system based on magnetic resonance imaging for the prediction of the difficulty of ultrasound-guided high-intensity focused ultrasound ablation for uterine fibroids
    Zhang, Ying
    Wang, Qian
    Wang, Yangyang
    Ma, Rong
    He, Min
    Zhang, Lian
    INTERNATIONAL JOURNAL OF HYPERTHERMIA, 2024, 41 (01)
  • [30] Magnetic resonance imaging-guided focused ultrasound for thermal ablation in the brain: A feasibility study in a swine model
    Cohen, Zvi R.
    Zaubermann, Jacob
    Harnof, Sagi
    Mardor, Yael
    Nass, Dvora
    Zadicario, Eyal
    Hananel, Arik
    Castel, David
    Faibel, Meir
    Ram, Zvi
    NEUROSURGERY, 2007, 60 (04) : 593 - 600