Effect of Radiofrequency Use on Hip Arthroscopy Irrigation Fluid Temperature

被引:24
|
作者
McCormick, Frank [1 ]
Alpaugh, Kyle [2 ]
Nwachukwu, Benedict U. [2 ]
Xu, Siyan [3 ]
Martin, Scott D. [2 ]
机构
[1] Midwest Orthoped Rush Sports Med, Rush Sports Med Fellowship Program, Chicago, IL USA
[2] Brigham & Womens Hosp, Dept Orthoped Surg, Boston, MA 02115 USA
[3] Boston Univ, Sch Med, Dept Biostat, Boston, MA 02118 USA
关键词
THERMAL CHONDROPLASTY; SHOULDER ARTHROSCOPY; ENERGY; BIPOLAR; CHONDROLYSIS; SURGERY;
D O I
10.1016/j.arthro.2012.10.001
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose: The purpose of this study was to determine operating parameters for joint fluid lavage using radiofrequency (RF) in maintaining intra-articular temperatures < 50 degrees C in the hip joint and to then quantify the influence of flow rate on maintaining safe intra-articular temperatures. Methods: Fiberoptic intra-articular thermometers at radial distance intervals of 1, 2, 5, and 10 mm, spanning cross-sectional areas of 3.14, 12.56, 78.5, and 314.1 mm(2), respectively, from the RF probe were used in 3 human hip cadaveric specimens at room temperature, with 9 trials per variable, using a 3-portal technique with a capsule release. Using a new Dyonics RF System continuously at the superior capsulolabral junction for 90 seconds, continuous temperatures were recorded at 50 mm Hg inflow and variable outflow intervals: no flow and 5, 15, and 30 seconds. Lavages were 1 second in duration on suction. Statistical comparison was through multivariate regression analysis and a logistic model. Results: Temperatures reached >= 50 degrees C at 5-mm radial distance from the probe in all but the 5-second pulse lavage group. Elevated temperatures were reached within 1 to 2 seconds locally (1- to 2-mm radial distance) and at a radial distance of 5 mm in the 15-, 30-, and 0-second lavage groups. Logistic regression revealed a reduction in the odds that temperatures >= 50 degrees C will occur as flow frequency increases every 30 (odds ratio = 0.68, P = .086); 15 (odds ratio = -1.22, P = .0067); and 5 (odds ratio = -4.26, P < .0001) seconds. Conclusions: Increasing-interval pulsed irrigation is effective in maintaining intra-articular temperature profiles below 50 degrees C during use of continuous RF ablation. Five-second-interval pulsed lavage is the longest flow interval identified during which fluid 5 mm radially from the RF device never reached temperatures > 50 degrees C. Clinical Relevance: Clinical guidelines for using the RF ablation include: meticulous technique, intermittent use, good inflow and outflow, and pulsed lavage at frequent intervals.
引用
收藏
页码:336 / 342
页数:7
相关论文
共 50 条
  • [41] Oxygen embolism after hydrogen peroxide irrigation during hip arthroscopy: a case report
    Peng, Zhengwu
    Li, Hui
    Cao, Ziqin
    Zhang, Wenchao
    Li, Hongxin
    Dai, Ruping
    Liu, Lei
    Mao, Xinzhan
    George, Daniel M.
    Huang, Tianlong
    BMC MUSCULOSKELETAL DISORDERS, 2020, 21 (01)
  • [42] Editorial Commentary: Shoulder Arthroscopy With Epinephrine Diluted Saline-Irrigation Fluid
    Moezzi, Darius
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2016, 32 (03): : 445 - 445
  • [43] Use of a larger surface area tip on bipolar radiofrequency wands in hip arthroscopy is associated with significantly lower traction and total surgery times
    Wininger, Austin E.
    Aflatooni, Justin O.
    Harris, Joshua D.
    JOURNAL OF HIP PRESERVATION SURGERY, 2022, 8 (03): : 270 - 273
  • [44] Massive intraperitoneal and extraperitoneal accumulation of irrigation fluid as a complication during knee arthroscopy
    Romero, J
    Smit, CM
    Zanetti, M
    ARTHROSCOPY, 1998, 14 (04): : 401 - 404
  • [45] Postoperative Brace Use After Hip Arthroscopy: A Systematic Review
    Mavrommatis, Sophia
    Feroe, Aliya G.
    Fader, Ryan R.
    Hassan, Mahad M.
    HSS JOURNAL, 2024, 20 (04) : 550 - 555
  • [46] Hip arthroscopy for femoroacetabular impingement: use escalating beyond the evidence
    Cicuttini, Flavia M.
    Teichtahl, Andrew J.
    Wang, Yuanyuan
    MEDICAL JOURNAL OF AUSTRALIA, 2017, 206 (10) : 424 - +
  • [47] Subacromial temperature profile during bipolar radiofrequency use in shoulder arthroscopy. Comparison of Coblation® vs. VAPR®
    Huynh, V.
    Barbier, O.
    Bajard, X.
    Bouchard, A.
    Ollat, D.
    Versier, G.
    ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2017, 103 (04) : 489 - 491
  • [48] The use of arthroscopy to document accurate position of core decompression of the hip
    Ruch, DS
    Satterfield, W
    ARTHROSCOPY, 1998, 14 (06): : 617 - 619
  • [49] Temperature Profile of Radiofrequency Probe Application in Wrist Arthroscopy: Monopolar Versus Bipolar
    Huber, Michaela
    Eder, Christoph
    Mueller, Michael
    Kujat, Richard
    Roll, Christina
    Nerlich, Michael
    Prantl, Lukas
    Gehmert, Sebastian
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2013, 29 (04): : 645 - 652
  • [50] The effect of prolonged laser activation on irrigation fluid temperature: an in vitro experimental study
    Tsaturyan, Arman
    Peteinaris, Angelis
    Pantazis, Lampros
    Farsari, Ergina
    Pagonis, Konstantinos
    Adamou, Constantinos
    Vagionis, Athanasios
    Natsos, Anastasios
    Liatsikos, Evangelos
    Kallidonis, Panagiotis
    WORLD JOURNAL OF UROLOGY, 2022, 40 (07) : 1873 - 1878