Effect of Radiofrequency Use on Hip Arthroscopy Irrigation Fluid Temperature

被引:24
|
作者
McCormick, Frank [1 ]
Alpaugh, Kyle [2 ]
Nwachukwu, Benedict U. [2 ]
Xu, Siyan [3 ]
Martin, Scott D. [2 ]
机构
[1] Midwest Orthoped Rush Sports Med, Rush Sports Med Fellowship Program, Chicago, IL USA
[2] Brigham & Womens Hosp, Dept Orthoped Surg, Boston, MA 02115 USA
[3] Boston Univ, Sch Med, Dept Biostat, Boston, MA 02118 USA
关键词
THERMAL CHONDROPLASTY; SHOULDER ARTHROSCOPY; ENERGY; BIPOLAR; CHONDROLYSIS; SURGERY;
D O I
10.1016/j.arthro.2012.10.001
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose: The purpose of this study was to determine operating parameters for joint fluid lavage using radiofrequency (RF) in maintaining intra-articular temperatures < 50 degrees C in the hip joint and to then quantify the influence of flow rate on maintaining safe intra-articular temperatures. Methods: Fiberoptic intra-articular thermometers at radial distance intervals of 1, 2, 5, and 10 mm, spanning cross-sectional areas of 3.14, 12.56, 78.5, and 314.1 mm(2), respectively, from the RF probe were used in 3 human hip cadaveric specimens at room temperature, with 9 trials per variable, using a 3-portal technique with a capsule release. Using a new Dyonics RF System continuously at the superior capsulolabral junction for 90 seconds, continuous temperatures were recorded at 50 mm Hg inflow and variable outflow intervals: no flow and 5, 15, and 30 seconds. Lavages were 1 second in duration on suction. Statistical comparison was through multivariate regression analysis and a logistic model. Results: Temperatures reached >= 50 degrees C at 5-mm radial distance from the probe in all but the 5-second pulse lavage group. Elevated temperatures were reached within 1 to 2 seconds locally (1- to 2-mm radial distance) and at a radial distance of 5 mm in the 15-, 30-, and 0-second lavage groups. Logistic regression revealed a reduction in the odds that temperatures >= 50 degrees C will occur as flow frequency increases every 30 (odds ratio = 0.68, P = .086); 15 (odds ratio = -1.22, P = .0067); and 5 (odds ratio = -4.26, P < .0001) seconds. Conclusions: Increasing-interval pulsed irrigation is effective in maintaining intra-articular temperature profiles below 50 degrees C during use of continuous RF ablation. Five-second-interval pulsed lavage is the longest flow interval identified during which fluid 5 mm radially from the RF device never reached temperatures > 50 degrees C. Clinical Relevance: Clinical guidelines for using the RF ablation include: meticulous technique, intermittent use, good inflow and outflow, and pulsed lavage at frequent intervals.
引用
收藏
页码:336 / 342
页数:7
相关论文
共 50 条
  • [1] Effect of Radiofrequency Energy on Glenohumeral Fluid Temperature During Shoulder Arthroscopy
    Good, Christopher R.
    Shindle, Michael K.
    Griffith, Matthew H.
    Wanich, Tony
    Warren, Russell F.
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2009, 91A (02): : 429 - 434
  • [2] Effect of Warmed Irrigation Solution on Core Body Temperature During Hip Arthroscopy for Femoroacetabular Impingement
    Parodi, Dante
    Valderrama, Juanjose
    Tobar, Carlos
    Besomi, Javier
    Lopez, Jaime
    Lara, Joaquin
    Ilic, Juan Pablo
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2014, 30 (01): : 36 - 41
  • [3] Fluid temperatures during radiofrequency use in shoulder arthroscopy: A cadaveric study
    McKeon, Brian
    Baltz, Matthew S.
    Curtis, Alan
    Scheller, Arnold
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2007, 16 (01) : 107 - 111
  • [4] Use of a Hip Arthroscopy Flexible Radiofrequency Device for Capsular Release in Frozen Shoulder
    Thompson, Stephen R.
    LeBel, Marie-Eve
    ARTHROSCOPY TECHNIQUES, 2012, 1 (01): : E75 - E78
  • [5] What are the current indications for use of radiofrequency devices in hip arthroscopy? A systematic review
    Suarez-Ahedo, Carlos
    Vemula, S. Pavan
    Stake, Christine E.
    Finley, Zachary A.
    Martin, Timothy J.
    Gui, Chengcheng
    Domb, Benjamin G.
    JOURNAL OF HIP PRESERVATION SURGERY, 2015, 2 (04): : 323 - 331
  • [6] Effects of irrigation fluid in shoulder arthroscopy
    Gupta, Surbhi
    Manjuladevi, M.
    Upadhyaya, K. S. Vasudeva
    Kutappa, A. M.
    Amaravathi, Rajkumar
    Arpana, J.
    INDIAN JOURNAL OF ANAESTHESIA, 2016, 60 (03) : 194 - 198
  • [7] Fluid extravasation during hip arthroscopy
    Stafford, Giles H.
    Malviya, Ajay
    Villar, Richard N.
    HIP INTERNATIONAL, 2011, 21 (06) : 740 - 743
  • [8] The Role of Flexible Radiofrequency Energy Probes in Hip Arthroscopy
    Schenker, Mara L.
    Philippon, Marc J.
    TECHNIQUES IN ORTHOPAEDICS, 2005, 20 (01) : 37 - 44
  • [9] Effects of Radiofrequency Probe Application on Irrigation Fluid Temperature in the Wrist Joint
    Sotereanos, Dean G.
    Darlis, Nickolaos A.
    Kokkalis, Zinon T.
    Zanaros, George
    Altman, Gregory T.
    Miller, Mark Carl
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2009, 34A (10): : 1832 - 1837
  • [10] The use of hip arthroscopy in the management of the pediatric hip
    Roy, Dennis R.
    JOURNAL OF HIP PRESERVATION SURGERY, 2016, 3 (02): : 97 - 107