Development of compartment syndrome after intravenous administration of an X-ray contrast medium

被引:0
|
作者
Hawi, N. [1 ]
Citak, M. [1 ]
Liodakis, E. [1 ]
Petri, M. [1 ]
Haasper, C. [1 ]
Krettek, C. [1 ]
Meller, R. [1 ]
机构
[1] Hannover Med Sch, Unfallchirurg Klin, D-30625 Hannover, Germany
来源
UNFALLCHIRURG | 2014年 / 117卷 / 04期
关键词
Forearm; Multiple trauma; Contrast medium administration; Computed tomography imaging; COMPUTED-TOMOGRAPHY; UPPER EXTREMITY; EXTRAVASATION; MANAGEMENT; INJECTION; FREQUENCY; ELEVATION; DIAGNOSIS; PRESSURE; INJURY;
D O I
10.1007/s00113-013-2393-2
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
The incidence of extravasation of contrast medium is reported in the literature to be between 0.2 % and 0.9 %. A rare consequence of this could be compartment syndrome of the affected limb which requires immediate treatment. We report the case of a patient who developed acute compartment syndrome of the forearm after intravenous injection of radiographic contrast medium in a radiovolar vein during a computed tomography (CT) scan for multiple trauma. The clinical symptoms with pain, loss of range of motion and sensitivity functions, measurement of compartment pressure and radiological images confirmed the diagnosis. After emergency dermatofasciotomy of the forearm the full range of motion and sensitivity functions could be restored.
引用
收藏
页码:374 / 378
页数:5
相关论文
共 50 条
  • [21] Extravasation after administration of X-ray contrast medium via the intraosseous route used in the emergency treatment of a severely burnt female patient
    Hoelman, H.
    Eikermann, C.
    Sakka, S. G.
    Wappler, F.
    [J]. ANASTHESIOLOGIE & INTENSIVMEDIZIN, 2021, 62 : 183 - 186
  • [23] EFFECT OF AN X-RAY CONTRAST THREAD ON CONTRAST DEVELOPMENT AND TISSUE COMPATIBILITY
    KINKEL, HJ
    HOLZMANN, S
    [J]. CHIRURG, 1969, 40 (09): : 426 - &
  • [24] Acute compartment syndrome of the forearm after paravasation of contrast medium. Case report
    Ensat, F.
    Babl, M.
    Spies, M.
    [J]. RADIOLOGE, 2010, 50 (03): : 272 - 276
  • [25] Gadolinium-DTPA as X-ray contrast medium in clinical studies
    Albrecht, T
    Dawson, P
    [J]. BRITISH JOURNAL OF RADIOLOGY, 2000, 73 (872): : 878 - 882
  • [26] Removal of the Iodinated X-ray Contrast Medium Diatrizoate by Anaerobic Transformation
    Redeker, Maria
    Wick, Arne
    Meermann, Bjoern
    Ternes, Thomas A.
    [J]. ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2014, 48 (17) : 10145 - 10154
  • [27] SODIUM METRIZOATE, A NEW UROGRAPHIC AND ANGIOGRAPHIC X-RAY CONTRAST MEDIUM
    HOPPE, JO
    DUPREY, LP
    BROUSSEAU, AC
    [J]. FEDERATION PROCEEDINGS, 1963, 22 (02) : 482 - &
  • [28] Recommendations for the prevention of X-ray contrast medium-induced neuropathy
    Möckel, M
    Bahr, F
    Leuner, C
    Kuhn, H
    Dietz, R
    [J]. ZEITSCHRIFT FUR KARDIOLOGIE, 2002, 91 (09): : 719 - 726
  • [29] EFFECTS OF X-RAY CONTRAST-MEDIUM ON BLOOD CALCIUM LEVELS
    WOLPERS, HG
    BALLER, D
    ENSINK, FBM
    ZIPFEL, J
    HELLIGE, G
    [J]. ZEITSCHRIFT FUR KARDIOLOGIE, 1980, 69 (03): : 191 - 191
  • [30] Development of an X-ray interferometer for high-resolution phase-contrast X-Ray imaging
    Hirano, K
    Momose, A
    [J]. JAPANESE JOURNAL OF APPLIED PHYSICS PART 2-LETTERS, 1999, 38 (12B): : L1556 - L1558