Factors influencing taper failure of modular revision hip stems

被引:20
|
作者
Krull, A. [1 ]
Morlock, M. M. [1 ]
Bishop, N. E. [2 ]
机构
[1] TUHH Hamburg Univ Technol, Inst Biomech, Denickestr 15, D-21073 Hamburg, Germany
[2] HAW Hamburg Univ Appl Sci, Dept Biomed Engn, Fak Life Sci, Ulmenliet 20, D-21033 Hamburg, Germany
关键词
Hip revision; Taper junction; Fracture; Corrosion; Fatigue; Strength; Titanium; Finite element model; Surface damage; HEAD-NECK TAPER; FRETTING CORROSION; CONTACT FORCES; FEMORAL STEMS; ARTHROPLASTY; FRACTURE; REPLACEMENT; PROSTHESIS; JUNCTION; JOINT;
D O I
10.1016/j.medengphy.2018.02.001
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Stem modularity of revision hip implant systems offers the advantage of the restoration of individual patient geometry but introduces additional interfaces, which are subjected to repetitive bending loading and have a propensity for fretting corrosion. The male stem taper is the weakest part of the modular junction due to its reduced cross section compared to the outside diameter of the stem. Taper fractures can be the consequence of overloading in combination with corrosion. The purpose of this study was to assess the influence of implant design factors, patient factors, and surgical factors on the risk of taper failure of the modular junction of revision stems. An analytical bending model was used to estimate the strength of the taper connection for pristine, fatigued and corroded conditions. Additionally, a finite element contact model of the taper connection was developed to assess the relative motion and potential for surface damage at the taper interface under physiological loading for varyied assembly and design parameters. Increasing the male taper diameter was shown to be the most effective means for increasing taper strength but would require a concurrent increase in the outer implant diameter to limit a greater risk of total surface damage for a thinner female taper wall. Increasing the assembly force decreases the total surface damage but not local magnitudes, which are probably responsible for crack initiation. It is suggested that in unfavourable loading conditions a monobloc implant system will reduce the risk of failure. (C) 2018 IPEM. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:65 / 73
页数:9
相关论文
共 50 条
  • [31] Fixation pattern of conical and cylindrical modular revision hip stems in different size bone defects
    Kinkel, Stefan
    Nadorf, Jan
    Thomsen, Marc N.
    Heisel, Christian
    Jahnke, Alexander
    Kretzer, Jan P.
    Jakubowitz, Eike
    INTERNATIONAL ORTHOPAEDICS, 2015, 39 (09) : 1819 - 1825
  • [32] The long-term success of modular proximal fixation stems in revision total hip arthroplasty
    Cameron, HU
    JOURNAL OF ARTHROPLASTY, 2002, 17 (04): : 138 - 141
  • [33] Indications, complications and outcomes of modular stems in total hip revision arthroplasty: a systematic review of the literature
    Cottino, Umberto
    Pirato, Francesco
    Battaglia, Domenico L.
    Dettoni, Federico
    Bruzzone, Matteo
    Rossi, Roberto
    MINERVA ORTHOPEDICS, 2024, 75 (03): : 243 - 254
  • [34] Modular Fluted Tapered Stems in Aseptic Oncologic Revision Total Hip Arthroplasty: A Game Changer?
    Bingham, Joshua S.
    Tibbo, Meagan E.
    Beauchamp, Christopher P.
    Lewallen, David G.
    Berry, Daniel J.
    Abdel, Matthew P.
    JOURNAL OF ARTHROPLASTY, 2020, 35 (12): : 3692 - 3696
  • [35] Fixation pattern of conical and cylindrical modular revision hip stems in different size bone defects
    Stefan Kinkel
    Jan Nadorf
    Marc N. Thomsen
    Christian Heisel
    Alexander Jahnke
    Jan P. Kretzer
    Eike Jakubowitz
    International Orthopaedics, 2015, 39 : 1819 - 1825
  • [36] Non-modular tapered fluted titanium stems in hip revision surgery GAINING ATTENTION
    Konan, S.
    Garbuz, D. S.
    Masri, B. A.
    Duncan, C. P.
    BONE & JOINT JOURNAL, 2014, 96B : 56 - 59
  • [37] Mid-Term Results of Modular Tapered Femoral Stems in Revision Total Hip Arthroplasty
    Marfo, Kojo A.
    Berend, Keith R.
    Adams, Joanne B.
    Morris, Michael J.
    Lombardi, Adolph V., Jr.
    SURGICAL TECHNOLOGY INTERNATIONAL-INTERNATIONAL DEVELOPMENTS IN SURGERY AND SURGICAL RESEARCH, 2019, 35
  • [38] Fractures of Corin 'Taper-Fit' CDH stems used in 'cement-in-cement' revision total hip replacement
    Briant-Evans, T. W.
    Norton, M. R.
    Fern, E. D.
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2007, 89B (03): : 393 - 395
  • [39] Failure analysis of three uncemented titanium-alloy modular total hip stems
    Paliwal, Manish
    Allan, D. Gordon
    Filip, Peter
    ENGINEERING FAILURE ANALYSIS, 2010, 17 (05) : 1230 - 1238
  • [40] Fracture of Cementless Femoral Stems at the Mid-Stem Junction in Modular Revision Hip Arthroplasty Systems
    Lakstein, Dror
    Eliaz, Noam
    Levi, Ofer
    Backstein, David
    Kosashvili, Yona
    Safir, Oleg
    Gross, Allan E.
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2011, 93A (01): : 57 - 65