Research of high power and stable laser in portable Raman spectrometer based on SHINERS technology

被引:0
|
作者
Cui Yongsheng [1 ]
Yin Yu [1 ]
Wu Yulin [1 ]
Ni Xuxiang [1 ]
Zhang Xiuda [1 ]
Yan Huimin [1 ]
机构
[1] Zhejiang Univ, Natl Engn & Technol Res Ctr Opt Instrument, State Key Lab Modern Opt Instrument, Hangzhou 310027, Peoples R China
关键词
SHINERS technology; High power lasers; Raman spectra; Incremental PID algorithm;
D O I
10.1117/12.2034595
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
The intensity of Raman light is very weak, which is only from 10(-12) to 10(-6) of the incident light. In order to obtain the required sensitivity, the traditional Raman spectrometer tends to be heavy weight and large volume, so it is often used as indoor test device. Based on the Shell-Isolated Nanoparticle-Enhanced Raman Spectroscopy (SHINERS) method, Raman optical spectrum signal can be enhanced significantly and the portable Raman spectrometer combined with SHINERS method will be widely used in various fields. The laser source must be stable enough and able to output monochromatic narrow band laser with stable power in the portable Raman spectrometer based on the SHINERS method. When the laser is working, the change of temperature can induce wavelength drift, thus the power stability of excitation light will be affected, so we need to strictly control the working temperature of the laser, In order to ensure the stability of laser power and output current, this paper adopts the WLD3343 laser constant current driver chip of Wavelength Electronics company and MCU P89LPC935 to drive LML - 785.0 BF - XX laser diode(LD). Using this scheme, the Raman spectrometer can be small in size and the drive current can be constant. At the same time, we can achieve functions such as slow start, over-current protection, over-voltage protection, etc. Continuous adjustable output can be realized under control, and the requirement of high power output can be satisfied. Max1968 chip is adopted to realize the accurate control of the laser's temperature. In this way, it can meet the demand of miniaturization. In term of temperature control, integral truncation effect of traditional PID algorithm is big, which is easy to cause static difference. Each output of incremental PID algorithm has nothing to do with the current position, and we can control the output coefficients to avoid full dose output and immoderate adjustment, then the speed of balance will be improved observably. Variable integral incremental digital PID algorithm is used in the TEC temperature control system. The experimental results show that comparing with other schemes, the output power of laser in our scheme is more stable and reliable, moreover the peak value is bigger, and the temperature can be precisely controlled in +/- 0.1 degrees C, then the volume of the device is smaller. Using this laser equipment, the ideal Raman spectra of materials can be obtained combined with SHINERS technology and spectrometer equipment.
引用
收藏
页数:10
相关论文
共 50 条
  • [31] Research progress of high-power free-space Raman amplification technology (invited)
    Bai, Zhenxu
    Hao, Xin
    Zheng, Hao
    Chen, Hui
    Qi, Yaoyao
    Ding, Jie
    Yan, Bingzheng
    Cui, Can
    Wang, Yulei
    Lv, Zhiwei
    [J]. Hongwai yu Jiguang Gongcheng/Infrared and Laser Engineering, 2023, 52 (08):
  • [32] Urine surface-enhanced Raman spectroscopy for non-invasive diabetic detection based on a portable Raman spectrometer
    Zou, Ye
    Huang, Meizhen
    Wang, Kehui
    Song, Biao
    Wang, Yang
    Chen, Jie
    Liu, Xi
    Li, Xia
    Lin, Lulu
    Huang, Gaozhong
    [J]. LASER PHYSICS LETTERS, 2016, 13 (06)
  • [33] High Power, High-Order Random Raman Fiber Laser Based on Tapered Fiber
    Lou, Zhaokai
    Jin, Xiaoxi
    Zhang, Hanwei
    Zhou, Pu
    Liu, Zejin
    [J]. IEEE PHOTONICS JOURNAL, 2017, 9 (01):
  • [34] Multiple myeloma detection based on blood plasma surface-enhanced Raman spectroscopy using a portable Raman spectrometer
    Chen, Jie
    Huang, Meizhen
    Zou, Ye
    Song, Biao
    Wang, Yang
    Wang, Kehui
    Li, Xia
    Liu, Xi
    Chen, Xiaofan
    Li, Feng
    Zhan, Yanxia
    [J]. LASER PHYSICS LETTERS, 2016, 13 (10)
  • [35] High-resolution laser spectrometer for fundamental and applied research
    B. N. Markov
    S. A. Babin
    Z. Blaszczak
    Yu. P. Gangrsky
    S. M. Kobtsev
    Yu. E. Penionzhkevich
    [J]. Bulletin of the Russian Academy of Sciences: Physics, 2007, 71 (6) : 844 - 847
  • [36] Portable Mass Spectrometer Introduction Technology Based on Membrane Continuous Introduction and Pulse Introduction
    Li, Bao-Qiang
    Li, Cui-Ping
    Zhang, Zhong-Yao
    Kong, Jing-Lin
    Zhang, Lin
    [J]. Journal of Chinese Mass Spectrometry Society, 2018, 39 (06) : 715 - 721
  • [37] Bidirectional pumped high power Raman fiber laser
    Xiao, Q.
    Yan, P.
    Li, D.
    Sun, J.
    Wang, X.
    Huang, Y.
    Gong, M.
    [J]. OPTICS EXPRESS, 2016, 24 (06): : 6758 - 6768
  • [38] High power photonic crystal fibre Raman laser
    Yan, PG
    Ruan, SC
    Yu, YQ
    Guo, CY
    Guo, Y
    Liu, CX
    [J]. CHINESE PHYSICS LETTERS, 2006, 23 (06) : 1476 - 1478
  • [39] High-power vortex Raman fiber laser
    Li, Yang
    Fan, Chenchen
    Hao, Xiulu
    Ma, Xiaoya
    Yao, Tianfu
    Xu, Jiangming
    Zeng, Xianglong
    Zhou, Pu
    [J]. Hongwai yu Jiguang Gongcheng/Infrared and Laser Engineering, 2023, 52 (06):
  • [40] Research on high precision output power control technology of external modulated laser diode
    Zhang, Xiaoqing
    Zhang, Chunxi
    Hu, Shuling
    Ou, Pan
    Hu, Hanwei
    [J]. Guangxue Xuebao/Acta Optica Sinica, 2008, 28 (SUPPL.): : 79 - 83