Research of high power and stable laser in portable Raman spectrometer based on SHINERS technology

被引:0
|
作者
Cui Yongsheng [1 ]
Yin Yu [1 ]
Wu Yulin [1 ]
Ni Xuxiang [1 ]
Zhang Xiuda [1 ]
Yan Huimin [1 ]
机构
[1] Zhejiang Univ, Natl Engn & Technol Res Ctr Opt Instrument, State Key Lab Modern Opt Instrument, Hangzhou 310027, Peoples R China
关键词
SHINERS technology; High power lasers; Raman spectra; Incremental PID algorithm;
D O I
10.1117/12.2034595
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
The intensity of Raman light is very weak, which is only from 10(-12) to 10(-6) of the incident light. In order to obtain the required sensitivity, the traditional Raman spectrometer tends to be heavy weight and large volume, so it is often used as indoor test device. Based on the Shell-Isolated Nanoparticle-Enhanced Raman Spectroscopy (SHINERS) method, Raman optical spectrum signal can be enhanced significantly and the portable Raman spectrometer combined with SHINERS method will be widely used in various fields. The laser source must be stable enough and able to output monochromatic narrow band laser with stable power in the portable Raman spectrometer based on the SHINERS method. When the laser is working, the change of temperature can induce wavelength drift, thus the power stability of excitation light will be affected, so we need to strictly control the working temperature of the laser, In order to ensure the stability of laser power and output current, this paper adopts the WLD3343 laser constant current driver chip of Wavelength Electronics company and MCU P89LPC935 to drive LML - 785.0 BF - XX laser diode(LD). Using this scheme, the Raman spectrometer can be small in size and the drive current can be constant. At the same time, we can achieve functions such as slow start, over-current protection, over-voltage protection, etc. Continuous adjustable output can be realized under control, and the requirement of high power output can be satisfied. Max1968 chip is adopted to realize the accurate control of the laser's temperature. In this way, it can meet the demand of miniaturization. In term of temperature control, integral truncation effect of traditional PID algorithm is big, which is easy to cause static difference. Each output of incremental PID algorithm has nothing to do with the current position, and we can control the output coefficients to avoid full dose output and immoderate adjustment, then the speed of balance will be improved observably. Variable integral incremental digital PID algorithm is used in the TEC temperature control system. The experimental results show that comparing with other schemes, the output power of laser in our scheme is more stable and reliable, moreover the peak value is bigger, and the temperature can be precisely controlled in +/- 0.1 degrees C, then the volume of the device is smaller. Using this laser equipment, the ideal Raman spectra of materials can be obtained combined with SHINERS technology and spectrometer equipment.
引用
收藏
页数:10
相关论文
共 50 条
  • [21] High average power diamond Raman laser
    Feve, Jean-Philippe M.
    Shortoff, Kevin E.
    Bohn, Matthew J.
    Brasseur, Jason K.
    [J]. OPTICS EXPRESS, 2011, 19 (02): : 913 - 922
  • [22] Experimental research on stimulated rotational Raman scattering in air with high-power laser
    Wang, Jing
    Han, Wei
    Zhou, Lidan
    Li, Ping
    Xiang, Yong
    Zhong, Wei
    Feng, Bin
    Zhang, Xiaomin
    [J]. Guangxue Xuebao/Acta Optica Sinica, 2011, 31 (SUPPL.1):
  • [23] A HIGH RESOLUTION RAMAN SPECTROMETER EQUIPPED WITH A CONVENTIONAL SOURCE AND A LASER SOURCE
    MICHEL, G
    [J]. SPECTROCHIMICA ACTA PART A-MOLECULAR SPECTROSCOPY, 1969, A 25 (03): : 517 - &
  • [24] Technology research on high power slab laser end-pumped with laser diode arrays
    Li, Mi
    Hu, Hao
    Li, Jianmin
    Wu, Yingchen
    Lei, Jun
    Lü, Wenqiang
    Shi, Yong
    Zhao, Na
    [J]. Guangxue Xuebao/Acta Optica Sinica, 2013, 33 (05):
  • [25] Design and Experimental Research of Probe in Handheld/portable Laser Raman Testing Device
    Gao Nan
    Zhang Yi-chao
    Xu Dan-yang
    Sui Cheng-hua
    [J]. ACTA PHOTONICA SINICA, 2019, 48 (05)
  • [26] Research on cleanness controlling technology of transport mirrors in high power laser system
    Li, Yangshuai
    Zhu, Jianqiang
    Wu, Yongzhong
    Jiao, Xiang
    Pang, Xiangyang
    [J]. 2015 INTERNATIONAL CONFERENCE ON OPTICAL INSTRUMENTS AND TECHNOLOGY: ADVANCED LASERS AND APPLICATIONS, 2015, 9621
  • [27] Research on a portable explosive detector based on MEMS technology
    Kong, Deyi
    Mei, Tao
    Tao, Yongchun
    Zhang, Dongfeng
    Zhang, Tao
    Lu, Wei
    Ni, Lin
    Zhang, Zhengyong
    [J]. Zhongguo Jixie Gongcheng/China Mechanical Engineering, 2005, 16 (SUPPL.): : 163 - 165
  • [28] High-power Narrowband Raman Fiber Laser Based on Random FBG
    Skvortsov, M. I.
    Abdullina, S. R.
    Vlasov, A. A.
    Zlobina, E. A.
    Lobach, I. A.
    Terentiev, V. S.
    Babin, S. A.
    [J]. 2017 PROGRESS IN ELECTROMAGNETICS RESEARCH SYMPOSIUM - SPRING (PIERS), 2017, : 410 - 412
  • [29] High stable power control of a laser diode
    Yang Jiu-ru
    Li Cheng
    Ye Hong-an
    Lu Guo-hui
    Jia Shi-lou
    [J]. OPTOELECTRONICS LETTERS, 2006, 2 (01) : 21 - 23
  • [30] High stable power control of a laser diode
    Jiu-ru Yang
    Cheng Li
    Hong-an Ye
    Guo-hui Lü
    Shi-lou Jia