Research of high power and stable laser in portable Raman spectrometer based on SHINERS technology

被引:0
|
作者
Cui Yongsheng [1 ]
Yin Yu [1 ]
Wu Yulin [1 ]
Ni Xuxiang [1 ]
Zhang Xiuda [1 ]
Yan Huimin [1 ]
机构
[1] Zhejiang Univ, Natl Engn & Technol Res Ctr Opt Instrument, State Key Lab Modern Opt Instrument, Hangzhou 310027, Peoples R China
关键词
SHINERS technology; High power lasers; Raman spectra; Incremental PID algorithm;
D O I
10.1117/12.2034595
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
The intensity of Raman light is very weak, which is only from 10(-12) to 10(-6) of the incident light. In order to obtain the required sensitivity, the traditional Raman spectrometer tends to be heavy weight and large volume, so it is often used as indoor test device. Based on the Shell-Isolated Nanoparticle-Enhanced Raman Spectroscopy (SHINERS) method, Raman optical spectrum signal can be enhanced significantly and the portable Raman spectrometer combined with SHINERS method will be widely used in various fields. The laser source must be stable enough and able to output monochromatic narrow band laser with stable power in the portable Raman spectrometer based on the SHINERS method. When the laser is working, the change of temperature can induce wavelength drift, thus the power stability of excitation light will be affected, so we need to strictly control the working temperature of the laser, In order to ensure the stability of laser power and output current, this paper adopts the WLD3343 laser constant current driver chip of Wavelength Electronics company and MCU P89LPC935 to drive LML - 785.0 BF - XX laser diode(LD). Using this scheme, the Raman spectrometer can be small in size and the drive current can be constant. At the same time, we can achieve functions such as slow start, over-current protection, over-voltage protection, etc. Continuous adjustable output can be realized under control, and the requirement of high power output can be satisfied. Max1968 chip is adopted to realize the accurate control of the laser's temperature. In this way, it can meet the demand of miniaturization. In term of temperature control, integral truncation effect of traditional PID algorithm is big, which is easy to cause static difference. Each output of incremental PID algorithm has nothing to do with the current position, and we can control the output coefficients to avoid full dose output and immoderate adjustment, then the speed of balance will be improved observably. Variable integral incremental digital PID algorithm is used in the TEC temperature control system. The experimental results show that comparing with other schemes, the output power of laser in our scheme is more stable and reliable, moreover the peak value is bigger, and the temperature can be precisely controlled in +/- 0.1 degrees C, then the volume of the device is smaller. Using this laser equipment, the ideal Raman spectra of materials can be obtained combined with SHINERS technology and spectrometer equipment.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] The research of digital circuit system for high accuracy CCD of portable Raman spectrometer
    Yin Yu
    Cui Yongsheng
    Zhang Xiuda
    Yan Huimin
    [J]. INTERNATIONAL SYMPOSIUM ON PHOTOELECTRONIC DETECTION AND IMAGING 2013: IMAGING SPECTROMETER TECHNOLOGIES AND APPLICATIONS, 2013, 8910
  • [2] Portable Raman dual-laser spectrometer for oil and gas
    Karas, Boris
    Grishkanich, Alexandr
    [J]. ENVIRONMENTAL EFFECTS ON LIGHT PROPAGATION AND ADAPTIVE SYSTEMS III, 2020, 11532
  • [3] High sensitivity and resolution integrated optical system for portable Raman spectrometer
    Tang, Ming
    Wang, Xin
    Fan Xianguang
    Li, Wei
    Xu, Yingjie
    Que, Jing
    He, Jian
    Zuo, Yong
    [J]. APPLIED OPTICS, 2016, 55 (26) : 7195 - 7203
  • [4] High Power Linearly Polarized Raman Fiber Laser With Stable Temporal Output
    Song, Jiaxin
    Wu, Hanshuo
    Ye, Jun
    Xu, Jiangming
    Zhang, Hanwei
    Zhou, Pu
    [J]. PHOTONIC SENSORS, 2019, 9 (01) : 43 - 48
  • [5] High Power Linearly Polarized Raman Fiber Laser With Stable Temporal Output
    Jiaxin Song
    Hanshuo Wu
    Jun Ye
    Jiangming Xu
    Hanwei Zhang
    Pu Zhou
    [J]. Photonic Sensors, 2019, 9 : 43 - 48
  • [6] Quantitative Analysis of Mixtures Based on Portable Spatial Heterodyne Raman Spectrometer
    Bai, Yunfei
    Luo, Haiyan
    Li, Zhiwei
    Ding, Yi
    Han, Yunfei
    Xiong, Wei
    [J]. ANALYTICAL LETTERS, 2024, 57 (13) : 2018 - 2033
  • [7] High power laser diode driver based on power converter technology
    Thompson, MT
    Schlecht, MF
    [J]. IEEE TRANSACTIONS ON POWER ELECTRONICS, 1997, 12 (01) : 46 - 52
  • [8] High power Raman diamond laser
    Feve, Jean-Philippe M.
    Bohn, Matthew J.
    Brasseur, Jason K.
    Shortoff, Kevin
    [J]. SOLID STATE LASERS XX: TECHNOLOGY AND DEVICES, 2011, 7912
  • [9] Research of CdZnTe detector based portable energy dispersive spectrometer
    CHENG Cheng WEI Yong-Bo XU Hui-Chao ZHAO Cui-Lan ZHANG Jin-Zhou PU Shi-Jie JIANG Da-Zhen (Shanghai Institute of Applied Physics
    [J]. Nuclear Science and Techniques, 2006, (02) : 106 - 112
  • [10] Optical design of portable Raman spectrometer based on-site rapid detection
    Luo, Weibo
    Yang, Jianfeng
    [J]. ICOSM 2020: OPTOELECTRONIC SCIENCE AND MATERIALS, 2020, 11606