CT-guided vertebroplasty and kyphoplasty.: Comparing technical success rate and complications in 101 cases

被引:18
|
作者
Weber, CH [1 ]
Krötz, M
Hoffmann, RT
Euler, E
Heining, S
Pfeifer, KJ
Reiser, M
Linsenmaier, U
机构
[1] LMU Munchen, Inst Klin Radiol, D-80336 Munich, Germany
[2] LMU Munchen, Chirurg Klin & Poliklin, D-80336 Munich, Germany
关键词
metastases; skeletal-axial; vertebroplasty; ablation procedures; osteoporosis;
D O I
10.1055/s-2006-926726
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To compare the technical success and complication rates in CT-guided vertebroplasty and kyphoplasty. Materials and Methods: From 2002 - 2005 69 patients (101 vertebrae) were treated with vertebroplasty (n = 82) or kyphoplasty (n = 19) using 4-slice MSCT with CT fluoroscopy as the sole guidance for the procedure. The underlying lesions were osteoporotic fractures in 78 vertebral bodies and 23 vertebral metastases. Results: Technical success was achieved in all 101 procedures. Post-interventional CT demonstrated asymptomatic cement leakage in 51/101 vertebrae. Kyphoplasty resulted in leakage in 11/19 (57.9%) and vertebroplasty in 40/82 (48.8 %) procedures. With p = 0.48 (Mann-Whitney Test) there was no significant difference between kyphoplasty and vertebroplasty with respect to the number of cement leakage occurrences. There was one minor complication of an L5 root irritation following radiofrequency ablation and vertebroplasty of a sarcoma metastasis which subsided without treatment after 8 weeks. There was one major complication of intraspinal cement leakage during tumor vertebroplasty causing T5 root compression and requiring laminectomy for cement removal. The overall rate of major complications requiring treatment was 0.99%. Conclusion: Vertebroplasty and kyphoplasty can be safely performed using only MSCT fluoroscopy guidance. The rate of major complications is very low. There was a high rate of small asymptomatic cement leakages which may have remained undetected with conventional fluoroscopy (CF). There was no statistically significant advantage for kyphoplasty with respect to cement leakage and the technical success rate.
引用
下载
收藏
页码:610 / 617
页数:8
相关论文
共 34 条
  • [31] Three-dimensional C-arm CT-guided transjugular intrahepatic portosystemic shunt placement: Feasibility, technical success and procedural time
    Ketelsen, Dominik
    Groezinger, Gerd
    Maurer, Michael
    Lauer, Ulrich M.
    Grosse, Ulrich
    Horger, Marius
    Nikolaou, Konstantin
    Syha, Roland
    EUROPEAN RADIOLOGY, 2016, 26 (12) : 4277 - 4283
  • [32] CT-guided biopsies of unspecified suspect intrahepatic lesions: pre-procedure Lipiodol-marking improves the biopsy success rate
    Langenbach, Marcel Christian
    Vogl, Thomas Joseph
    Buchinger, Amelie
    Eichler, Katrin
    Scholtz, Jan-Erik
    Hammerstingl, Renate
    Gruber-Rouh, Tatjana
    RADIOLOGY AND ONCOLOGY, 2023, 57 (02) : 158 - 167
  • [33] Intermittent CT fluoroscopic guided lung biopsy - Retrospective analysis of success rate, radiation exposure, complications and duration of procedure
    Gupta, Ruchi
    Sinha, Neetu
    Kumar, Prem
    Bhadani, Punam
    Rai, Deependra Kumar
    Kumar, Subhash
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2019, 27 (02) : 287 - 296
  • [34] INDICATIONS AND LIMITATIONS FOR CT-GUIDED STEREOTAXIC SURGERY OF HYPERTENSIVE INTRACEREBRAL HEMORRHAGE, BASED ON THE ANALYSIS OF POSTOPERATIVE COMPLICATIONS AND POOR ABILITY OF DAILY LIVING IN 158 CASES
    HOKAMA, M
    TANIZAKI, Y
    MASTUO, K
    HONGO, K
    KOBAYASHI, S
    ACTA NEUROCHIRURGICA, 1993, 125 (1-4) : 27 - 33