CT-guided vertebroplasty and kyphoplasty.: Comparing technical success rate and complications in 101 cases

被引:18
|
作者
Weber, CH [1 ]
Krötz, M
Hoffmann, RT
Euler, E
Heining, S
Pfeifer, KJ
Reiser, M
Linsenmaier, U
机构
[1] LMU Munchen, Inst Klin Radiol, D-80336 Munich, Germany
[2] LMU Munchen, Chirurg Klin & Poliklin, D-80336 Munich, Germany
关键词
metastases; skeletal-axial; vertebroplasty; ablation procedures; osteoporosis;
D O I
10.1055/s-2006-926726
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To compare the technical success and complication rates in CT-guided vertebroplasty and kyphoplasty. Materials and Methods: From 2002 - 2005 69 patients (101 vertebrae) were treated with vertebroplasty (n = 82) or kyphoplasty (n = 19) using 4-slice MSCT with CT fluoroscopy as the sole guidance for the procedure. The underlying lesions were osteoporotic fractures in 78 vertebral bodies and 23 vertebral metastases. Results: Technical success was achieved in all 101 procedures. Post-interventional CT demonstrated asymptomatic cement leakage in 51/101 vertebrae. Kyphoplasty resulted in leakage in 11/19 (57.9%) and vertebroplasty in 40/82 (48.8 %) procedures. With p = 0.48 (Mann-Whitney Test) there was no significant difference between kyphoplasty and vertebroplasty with respect to the number of cement leakage occurrences. There was one minor complication of an L5 root irritation following radiofrequency ablation and vertebroplasty of a sarcoma metastasis which subsided without treatment after 8 weeks. There was one major complication of intraspinal cement leakage during tumor vertebroplasty causing T5 root compression and requiring laminectomy for cement removal. The overall rate of major complications requiring treatment was 0.99%. Conclusion: Vertebroplasty and kyphoplasty can be safely performed using only MSCT fluoroscopy guidance. The rate of major complications is very low. There was a high rate of small asymptomatic cement leakages which may have remained undetected with conventional fluoroscopy (CF). There was no statistically significant advantage for kyphoplasty with respect to cement leakage and the technical success rate.
引用
下载
收藏
页码:610 / 617
页数:8
相关论文
共 34 条
  • [21] Reproducibility of "the Papanicolaou Society of Cytopathology system for reporting respiratory cytology" - A retrospective analysis of 101 cases of CT-guided FNAC
    Boler, Anup Kumar
    Banu, Nasreen
    Bose, Koushik
    Roy, Shreosee
    Bandyopadhyay, Arghya
    DIAGNOSTIC CYTOPATHOLOGY, 2020, 48 (08) : 701 - 705
  • [22] CT-guided percutaneous skull biopsy using a drill-assisted system: Technical report of two cases
    Wallace, Adam N.
    Tomasian, Anderanik
    Hsi, Andy C.
    Chang, Randy O.
    Jennings, Jack W.
    INTERVENTIONAL NEURORADIOLOGY, 2015, 21 (06) : 774 - 779
  • [23] Safety profile and technical success of narrow window CT-guided percutaneous biopsy with blunt needle approach in the abdomen and pelvis
    Francesca Rigiroli
    Andrés Camacho
    Andrew Chung
    Syed Yasir Andrabi
    Alexander Brook
    Bettina Siewert
    Muneeb Ahmed
    Olga R. Brook
    European Radiology, 2024, 34 : 2364 - 2373
  • [24] Safety profile and technical success of narrow window CT-guided percutaneous biopsy with blunt needle approach in the abdomen and pelvis
    Rigiroli, Francesca
    Camacho, Andres
    Chung, Andrew
    Andrabi, Syed Yasir
    Brook, Alexander
    Siewert, Bettina
    Ahmed, Muneeb
    Brook, Olga R.
    EUROPEAN RADIOLOGY, 2024, 34 (04) : 2364 - 2373
  • [25] Liver malignant CT-guided brachytherapy in breast cancer Phase II Study for Evaluation of Effectiveness, safety and technical success
    Wieners, G.
    Mohnike, K.
    Peters, N.
    Bischoff, J.
    Ruehl, R.
    Seidensticker, M.
    Walke, M.
    Gademann, G.
    Wust, P.
    Pech, M.
    Ricke, J.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2010, 186 : 150 - 150
  • [26] Success and complication rate of CT-guided marking of pulmonary nodules with coil wires for video-assisted thoracoscopic surgery (VATS)
    Krueger, K.
    Eyl, G.
    Morgenroth, C.
    Schneider, P.
    Hoelscher, A.
    Lackner, K.
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2006, 178 (12): : 1250 - 1254
  • [27] The success rate and associated risk factors of CT-guided percutaneous radiofrequency sympathectomy in the treatment of primary hyperhidrosis: A retrospective observational trial
    Han, Zixin
    Rui, Min
    Ni, Chaobo
    Zhu, Jianjun
    Xu, Longsheng
    Yao, Ming
    JOURNAL OF CLINICAL NEUROSCIENCE, 2023, 118 : 81 - 89
  • [28] Predictors of Technical Success and Rate of Complications of Image-Guided Percutaneous Transthoracic Lung Needle Biopsy of Pulmonary Tumors
    Otto, Stephan
    Mensel, Birger
    Friedrich, Nele
    Schaefer, Sophia
    Mahlke, Christoph
    von Bernstorff, Wolfram
    Bock, Karen
    Hosten, Norbert
    Kuehn, Jens-Peter
    PLOS ONE, 2015, 10 (04):
  • [29] Pulmonary lntraparenchymal Blood Patching Decreases the Rate of Pneumothorax-Related Complications following Percutaneous CT-Guided Needle Biopsy
    Graffy, Peter
    Loomis, Scott B.
    Pickhardt, Perry J.
    Lubner, Meghan G.
    Kitchin, Douglas R.
    Lee, Fred T., Jr.
    Hinshaw, J. Louis
    JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2017, 28 (04) : 608 - 613
  • [30] Three-dimensional C-arm CT-guided transjugular intrahepatic portosystemic shunt placement: Feasibility, technical success and procedural time
    Dominik Ketelsen
    Gerd Groezinger
    Michael Maurer
    Ulrich M. Lauer
    Ulrich Grosse
    Marius Horger
    Konstantin Nikolaou
    Roland Syha
    European Radiology, 2016, 26 : 4277 - 4283