Numerical Model of Realistic Human Head Phantom

被引:0
|
作者
Gombarska, Daniela [1 ]
Psenakova, Zuzana [1 ]
Gajdosova, Andrea [1 ]
机构
[1] Univ Zilina, Fac Elecr Engn & Informat Technol, Dept Electromagnet & Biomed Engn, Zilina, Slovakia
关键词
numerical model; human head phantom; electromagnetic field; exposure; SAR; TEMPERATURE RISE; WIDE-RANGE; FREQUENCIES; COMPUTATION; SAR;
D O I
10.1109/CPEE56060.2022.9919415
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
The article focuses on developing a simulation model of the realistic shape human head phantom used for investigating the influence of the electromagnetic field on the human body and the processes taking place in it. The introductory part is reserved to describing the modelled antennas and the human head phantom itself. The results of numerical simulations and measurements on a realistic human head phantom are compared.
引用
收藏
页数:4
相关论文
共 50 条
  • [31] Numerical human head model for traumatic injury assessment
    Hyung-Yun Choi
    [J]. KSME International Journal, 2001, 15 : 995 - 1001
  • [32] Numerical human head model for traumatic injury assessment
    Choi, HY
    [J]. KSME INTERNATIONAL JOURNAL, 2001, 15 (07): : 995 - 1001
  • [33] Numerical model of electrical potential within the human head
    Nixon, JB
    Rasser, PE
    Teubner, MD
    Clark, CR
    Bottema, MJ
    [J]. INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN ENGINEERING, 2003, 56 (15) : 2353 - 2366
  • [34] A New Head Phantom With Realistic Shape and Spatially Varying Skull Resistivity Distribution
    Li, Jian-Bo
    Tang, Chi
    Dai, Meng
    Liu, Geng
    Shi, Xue-Tao
    Yang, Bin
    Xu, Can-Hua
    Fu, Feng
    You, Fu-Sheng
    Tang, Meng-Xing
    Dong, Xiu-Zhen
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2014, 61 (02) : 254 - 263
  • [35] THE USE OF A REALISTIC HEAD BRAIN PHANTOM FOR CALIBRATION OF ACTIVITY CONCENTRATION MEASUREMENTS WITH SPECT
    NICKEL, O
    BALZFRITZ, A
    BERNDT, J
    HAHN, K
    [J]. RADIATION PROTECTION DOSIMETRY, 1993, 49 (1-3) : 317 - 320
  • [36] Validation of CT brain perfusion methods using a realistic dynamic head phantom
    Riordan, Alan J.
    Prokop, Mathias
    Viergever, Max A.
    Dankbaar, Jan Willem
    Smit, Ewoud J.
    de Jong, Hugo W. A. M.
    [J]. MEDICAL PHYSICS, 2011, 38 (06) : 3212 - 3221
  • [37] A realistic Phantom of the head for the Validation of attenuation corrections methods in PET-MRI
    Harries, J.
    Jochimsen, T. H.
    Scholz, T.
    Schlender, T.
    Barthel, H.
    Sabri, O.
    Sattler, B.
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2020, 47 (SUPPL 1) : S451 - S451
  • [38] Realistic human head model for EEG from both the geometry and conductivity aspects
    P. Wen
    K. Pope
    [J]. Australasian Physics & Engineering Sciences in Medicine, 2003, 26 (1):
  • [39] Field Distribution of Transcranial Static Magnetic Stimulation in Realistic Human Head Model
    Tharayil, Joseph J.
    Goetz, Stefan M.
    Bernabei, John M.
    Peterchev, Angel V.
    [J]. NEUROMODULATION, 2018, 21 (04): : 340 - 347
  • [40] Simplified realistic human head model for simulating Tumor Treating Fields (TTFields)
    Wenger, Cornelia
    Bomzon, Ze'ev
    Salvador, Ricardo
    Basser, Peter J.
    Miranda, Pedro C.
    [J]. 2016 38TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2016, : 5664 - 5667