Accuracy of modified CAD/CAM generated wafer for orthognathic surgery

被引:5
|
作者
Park, Jin Hoo [1 ]
Lee, Yong-Bin [2 ]
Kim, Sang Yoon [3 ,4 ]
Kim, Hyung Jun [1 ]
Jung, Young-Soo [1 ]
Jung, Hwi-Dong [1 ]
机构
[1] Yonsei Univ, Dept Oral & Maxillofacial Surg, Oral Sci Res Inst, Coll Dent, Seoul, South Korea
[2] Hankook Gen Hosp, Dept Oral & Maxillofacial Surg, Cheongju, South Korea
[3] INOVA Fairfax Hosp, Attending, Falls Church, VA USA
[4] Harvard MGH Oral & Maxillofacial Surg, Boston, MA USA
来源
PLOS ONE | 2019年 / 14卷 / 05期
关键词
COMPUTER-AIDED-DESIGN; TITANIUM PLATES; MODEL SURGERY; SPLINTS; MOVEMENT; PROTOCOL; GUIDES;
D O I
10.1371/journal.pone.0216945
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
The aim of this study was to investigate an accuracy of modified CAD/CAM generated wafers for orthognathic surgery. A total of 20 patients who had undergone bimaxillary orthognathic surgery were included and divided into two groups: A conventional CAD/CAM generated intermediate wafer and a modified CAD/CAM generated intermediate wafer. A series of CT images were taken to compare the virtual simulations with the actual postoperative outcomes(1 month after surgery). In conventional group, the mean difference of maxillary position between virtual simulation models and postoperative results was 0.78mm and overall average error within 1mm was observed in 66.4% of the repositioned maxilla. In modified group, the mean difference was 0.77mm and overall average error within 1mm was observed in 68.3%. There were no significant statistic differences between two groups in maxillary position. This study suggests that the CAD/CAM generated wafer provides excellent accuracy. The modified CAD/CAM wafer was only comparable to conventional design in accuracy and it cannot guarantee the superior precision. However, the modified design could be beneficial in cases with unstable condylar position or for inexperienced surgeons.
引用
收藏
页数:8
相关论文
共 50 条
  • [31] SURGICAL ACCURACY IN ORTHOGNATHIC SURGERY - INVITED COMMENT
    POSPISIL, OA
    [J]. BRITISH JOURNAL OF ORAL & MAXILLOFACIAL SURGERY, 1993, 31 (06): : 349 - 350
  • [32] Accuracy of computer-assisted orthognathic surgery
    De Riu, Giacomo
    Virdis, Paola Ilaria
    Meloni, Silvio Mario
    Lumbau, Aurea
    Vaira, Luigi Angelo
    [J]. JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY, 2018, 46 (02) : 293 - 298
  • [33] Accuracy of maxillary repositioning surgery using CAD/CAM customized surgical guides and fixation plates
    Wong, A.
    Goonewardene, M. S.
    Allan, B. P.
    Mian, A. S.
    Rea, A.
    [J]. INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2021, 50 (04) : 494 - 500
  • [34] Accuracy of perioperative mandibular positions in orthognathic surgery
    Borba, A. M.
    Ribeiro-Junior, O.
    Brozoski, M. A.
    Ce, P. S.
    Espinosa, M. M.
    Deboni, M. C. Z.
    Miloro, M.
    Naclerio-Homem, M. G.
    [J]. INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2014, 43 (08) : 972 - 979
  • [35] A novel technique to secure the occlusal wafer during orthognathic surgery
    Abdelrahman, Ahmed
    Johnston, Colin
    Earl, Philip
    Opie, Neil
    [J]. BRITISH JOURNAL OF ORAL & MAXILLOFACIAL SURGERY, 2010, 48 (05): : 389 - 390
  • [36] Marginal accuracy of CAD/CAM composite crown.
    Hikita, K
    Maida, T
    Kobayashi, K
    Yorimoto, T
    [J]. JOURNAL OF DENTAL RESEARCH, 2002, 81 : A239 - A239
  • [37] Computer-aided design and computer-aided modeling (CAD/CAM) generated surgical splints, cutting guides and custom-made implants: Which indications in orthognathic surgery?
    Scolozzi, P.
    [J]. REVUE DE STOMATOLOGIE DE CHIRURGIE MAXILLO-FACIALE ET DE CHIRURGIE ORALE, 2015, 116 (06) : 343 - 349
  • [38] New protocol for three-dimensional surgical planning and CAD/CAM splint generation in orthognathic surgery: an in vitro and in vivo study
    Hernandez-Alfaro, F.
    Guijarro-Martinez, R.
    [J]. INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2013, 42 (12) : 1547 - 1556
  • [39] A novel CAD/CAM composite occlusal splint for intraoperative verification in single-splint two-jaw orthognathic surgery
    Lo, Lun-Jou
    Niu, Lien-Shin
    Liao, Chun-Hao
    Lin, Hsiu-Hsia
    [J]. BIOMEDICAL JOURNAL, 2021, 44 (03) : 353 - 362
  • [40] Precision of a CAD/CAM-engineered surgical template based on a facebow for orthognathic surgery: an experiment with a rapid prototyping maxillary model
    Lee, Jae-Won
    Lim, Se-Ho
    Kim, Moon-Key
    Kang, Sang-Hoon
    [J]. ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY, 2015, 120 (06): : 684 - 692