Accuracy of modified CAD/CAM generated wafer for orthognathic surgery

被引:5
|
作者
Park, Jin Hoo [1 ]
Lee, Yong-Bin [2 ]
Kim, Sang Yoon [3 ,4 ]
Kim, Hyung Jun [1 ]
Jung, Young-Soo [1 ]
Jung, Hwi-Dong [1 ]
机构
[1] Yonsei Univ, Dept Oral & Maxillofacial Surg, Oral Sci Res Inst, Coll Dent, Seoul, South Korea
[2] Hankook Gen Hosp, Dept Oral & Maxillofacial Surg, Cheongju, South Korea
[3] INOVA Fairfax Hosp, Attending, Falls Church, VA USA
[4] Harvard MGH Oral & Maxillofacial Surg, Boston, MA USA
来源
PLOS ONE | 2019年 / 14卷 / 05期
关键词
COMPUTER-AIDED-DESIGN; TITANIUM PLATES; MODEL SURGERY; SPLINTS; MOVEMENT; PROTOCOL; GUIDES;
D O I
10.1371/journal.pone.0216945
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
The aim of this study was to investigate an accuracy of modified CAD/CAM generated wafers for orthognathic surgery. A total of 20 patients who had undergone bimaxillary orthognathic surgery were included and divided into two groups: A conventional CAD/CAM generated intermediate wafer and a modified CAD/CAM generated intermediate wafer. A series of CT images were taken to compare the virtual simulations with the actual postoperative outcomes(1 month after surgery). In conventional group, the mean difference of maxillary position between virtual simulation models and postoperative results was 0.78mm and overall average error within 1mm was observed in 66.4% of the repositioned maxilla. In modified group, the mean difference was 0.77mm and overall average error within 1mm was observed in 68.3%. There were no significant statistic differences between two groups in maxillary position. This study suggests that the CAD/CAM generated wafer provides excellent accuracy. The modified CAD/CAM wafer was only comparable to conventional design in accuracy and it cannot guarantee the superior precision. However, the modified design could be beneficial in cases with unstable condylar position or for inexperienced surgeons.
引用
收藏
页数:8
相关论文
共 50 条
  • [21] ACCURACY OF CEPHALOMETRIC PREDICTION IN ORTHOGNATHIC SURGERY
    FRIEDE, H
    KAHNBERG, KE
    ADELL, R
    RIDELL, A
    [J]. JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 1987, 45 (09) : 754 - 760
  • [22] THE ACCURACY OF VIDEO IMAGING IN ORTHOGNATHIC SURGERY
    SINCLAIR, PM
    KILPELAINEN, P
    PHILLIPS, C
    WHITE, RP
    ROGERS, L
    SARVER, DM
    [J]. AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 1995, 107 (02) : 177 - 185
  • [23] ACCURACY OF STEREOMETRY IN ASSESSING ORTHOGNATHIC SURGERY
    KING, GE
    BAYS, RA
    [J]. PROCEEDINGS OF THE SOCIETY OF PHOTO-OPTICAL INSTRUMENTATION ENGINEERS, 1983, 361 : 224 - 228
  • [24] Accuracy of Computer-Guided Implant Surgery by a CAD/CAM and Laser Scanning Technique
    Zhao, Xue Zhu
    Xu, Wei Hua
    Tang, Zhi Hui
    Wu, Min Jie
    Zhu, Jie
    Chen, Si
    [J]. CHINESE JOURNAL OF DENTAL RESEARCH, 2014, 17 (01): : 31 - 36
  • [25] ACCURACY OF VIRTUALLY PLANNED AND CAD/CAM-GUIDED IMPLANT SURGERY ON PLASTIC MODELS
    Pettersson, Andreas
    Kero, Timo
    Soderberg, Rikard
    Nasstrom, Karin
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2014, 112 (06): : 1472 - 1478
  • [26] Use of CAD-CAM technology to improve orthognathic surgery outcomes in patients with severe obstructive sleep apnoea syndrome
    Rossi, Diego Sergio
    Romano, Michele
    Sweed, Ahmed Hassan
    Baj, Alessandro
    Gianni, Aldo Bruno
    Beltramini, Giada Anna
    [J]. JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY, 2019, 47 (09) : 1331 - 1337
  • [27] A novel method of computer aided orthognathic surgery using individual CAD/CAM templates: a combination of osteotomy and repositioning guides
    Li, Biao
    Zhang, Lei
    Sun, Hao
    Yuan, Jianbing
    Shen, Steve G. F.
    Wang, Xudong
    [J]. BRITISH JOURNAL OF ORAL & MAXILLOFACIAL SURGERY, 2013, 51 (08): : E239 - E244
  • [28] EVALUATING CAD-CAM GENERATED CERAMIC VENEERS
    LIU, PR
    ISENBERG, BP
    LEINFELDER, KF
    [J]. JOURNAL OF THE AMERICAN DENTAL ASSOCIATION, 1993, 124 (04): : 59 - 63
  • [29] Clinical evaluation of CAD/CAM generated restorations.
    Sarrett, D
    Brooks, CN
    Dishman, M
    Albinder, S
    [J]. JOURNAL OF DENTAL RESEARCH, 1998, 77 : 913 - 913
  • [30] Correlation between accuracy of crowns fabricated using CAD/CAM and elastic deformation of CAD/CAM materials
    Yara, A
    Goto, S
    Ogura, H
    [J]. DENTAL MATERIALS JOURNAL, 2004, 23 (04) : 572 - 576