Comparison of the Miller Laryngoscope and Videolaryngoscope for Tracheal Intubation by Novice Doctors during Neonatal Cardiopulmonary Resuscitation: A Randomized Crossover Simulation Trial

被引:7
|
作者
Komasawa, Nobuyasu [1 ]
Ueki, Ryusuke [2 ]
Kaminoh, Yoshiroh [3 ]
Nishi, Shin-ichi [4 ]
机构
[1] Osaka Med Coll, Dept Anesthesiol, Takatsuki, Osaka 5698686, Japan
[2] Hyogo Coll Med, Dept Anesthesiol, Nishinomiya, Hyogo 6638501, Japan
[3] Social Insurance Kinan Hosp, Dept Anesthesiol, Tanabe, Japan
[4] Hyogo Coll Med, Div Intens Care Unit, Nishinomiya, Hyogo 6638501, Japan
关键词
Pentax-AWS Airway Scope; Miller laryngoscope; chest compression; manikin; neonatal; LARYNGEAL MASK AIRWAY; PENTAX-AWS; PENTAX-AWS(R); ENDOTRACHEAL; PRESSURE; INFANTS;
D O I
10.1055/s-0034-1395482
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
Objective Recent guidelines for neonatal cardiopulmonary resuscitation emphasize the importance of adequate ventilation. In cases of failed resuscitation with positive pressure ventilation, tracheal intubation and chest compressions are recommended. The present study compared the utility of the Miller laryngoscope (Mil) and the videolaryngoscope Pentax-AWS Airway Scope (AWS; Hoya, Tokyo, Japan) with an infant or neonatal-sized Intlock (AWS-N; Pentax) during chest compressions on a neonatal manikin. Study Design A total of 23 novice doctors performed tracheal intubation on a neonatal manikin using the Mil and AWS-N, with or without chest compressions. Results In the Mil trials, all participants secured the airway without chest compressions, but nine failed with compressions (p < 0.001). In AWS-N trials, all participants succeeded regardless of whether chest compressions were performed or not. Intubation time was significantly longer with chest compressions with the Mil (p<0.001), but not with the AWS-N. Laryngoscopy difficulty, as assessed by a visual analog scale (VAS), increased significantly with chest compressions with the Mil, but not with the AWS-N, while the VAS for tube passage through the glottis increased with compressions with the Mil, but not with the AWS-N. Conclusion The AWS-N is an effective device for endotracheal intubation during chest compressions in neonatal simulations performed by novice doctors.
引用
收藏
页码:809 / 813
页数:5
相关论文
共 50 条
  • [31] Efficacy of stylet angulation at the holding position during tracheal intubation with a videolaryngoscope: a randomized controlled trial
    Ryo Wakabayashi
    Yuki Shiko
    Tomofumi Kodaira
    Yuko Shiroshita
    Hitomi Otsuka
    Kosuke Baba
    Norimasa Hishinuma
    Scientific Reports, 11
  • [32] Efficacy of stylet angulation at the holding position during tracheal intubation with a videolaryngoscope: a randomized controlled trial
    Wakabayashi, Ryo
    Shiko, Yuki
    Kodaira, Tomofumi
    Shiroshita, Yuko
    Otsuka, Hitomi
    Baba, Kosuke
    Hishinuma, Norimasa
    SCIENTIFIC REPORTS, 2021, 11 (01)
  • [33] Comparison of Miller and Airtraq laryngoscopes for orotracheal intubation by physicians wearing CBRN protective equipment during infant resuscitation: a randomized crossover simulation study
    Claret, Pierre-Geraud
    Asencio, Renaud
    Rogier, Damien
    Roger, Claire
    Fournier, Philippe
    Tran, Tu-Anh
    Sebbane, Mustapha
    Bobbia, Xavier
    de la Coussaye, Jean Emmanuel
    SCANDINAVIAN JOURNAL OF TRAUMA RESUSCITATION & EMERGENCY MEDICINE, 2016, 24
  • [34] Comparison of Miller and Airtraq laryngoscopes for orotracheal intubation by physicians wearing CBRN protective equipment during infant resuscitation: a randomized crossover simulation study
    Pierre-Géraud Claret
    Renaud Asencio
    Damien Rogier
    Claire Roger
    Philippe Fournier
    Tu-Anh Tran
    Mustapha Sebbane
    Xavier Bobbia
    Jean Emmanuel de La Coussaye
    Scandinavian Journal of Trauma, Resuscitation and Emergency Medicine, 24
  • [35] Randomized crossover trial comparing cervical spine motion during tracheal intubation with a Macintosh laryngoscope versus a C-MAC D-blade videolaryngoscope in a simulated immobilized cervical spine
    Hyesun Paik
    Hee-Pyoung Park
    BMC Anesthesiology, 20
  • [36] Randomized crossover trial comparing cervical spine motion during tracheal intubation with a Macintosh laryngoscope versus a C-MAC D-blade videolaryngoscope in a simulated immobilized cervical spine
    Paik, Hyesun
    Park, Hee-Pyoung
    BMC ANESTHESIOLOGY, 2020, 20 (01)
  • [37] Can the ETView VivaSight SL Rival Conventional Intubation Using the Macintosh Laryngoscope During Adult Resuscitation by Novice Physicians? A Randomized Crossover Manikin Study
    Szarpak, Lukasz
    Truszewski, Zenon
    Czyzewski, Lukasz
    Kurowski, Andrzej
    MEDICINE, 2015, 94 (21)
  • [38] Tracheal intubation during chest compressions using Pentax-AWSA®, GlideScopeA®, and Macintosh laryngoscope: a randomized crossover trial using a mannequin
    Shin, Dong Hyuk
    Choi, Pil Cho
    Han, Sang Kuk
    CANADIAN JOURNAL OF ANESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 2011, 58 (08): : 733 - 739
  • [39] Comparison of three types of intubation stylets for tracheal intubation with a McGrath MAC® video laryngoscope by novice intubators in simulated cervical immobilisation: A randomised crossover manikin study
    Kim, Sung-Wook
    Kim, Ji-Hoon
    Kim, Young-Min
    Park, Jung Taek
    Choi, Seung Pill
    HONG KONG JOURNAL OF EMERGENCY MEDICINE, 2018, 25 (01) : 27 - 32
  • [40] Child endotracheal intubation with a Clarus Levitan fiberoptic stylet vs Macintosh laryngoscope during resuscitation performed by paramedics: a randomized crossover manikin trial
    Szarpak, Lukasz
    Truszewski, Zenon
    Czyzewski, Lukasz
    Kurowski, Andrzej
    Bogdanski, Lukasz
    Zasko, Piotr
    AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2015, 33 (11): : 1547 - 1551