Comparison of the Miller Laryngoscope and Videolaryngoscope for Tracheal Intubation by Novice Doctors during Neonatal Cardiopulmonary Resuscitation: A Randomized Crossover Simulation Trial

被引:7
|
作者
Komasawa, Nobuyasu [1 ]
Ueki, Ryusuke [2 ]
Kaminoh, Yoshiroh [3 ]
Nishi, Shin-ichi [4 ]
机构
[1] Osaka Med Coll, Dept Anesthesiol, Takatsuki, Osaka 5698686, Japan
[2] Hyogo Coll Med, Dept Anesthesiol, Nishinomiya, Hyogo 6638501, Japan
[3] Social Insurance Kinan Hosp, Dept Anesthesiol, Tanabe, Japan
[4] Hyogo Coll Med, Div Intens Care Unit, Nishinomiya, Hyogo 6638501, Japan
关键词
Pentax-AWS Airway Scope; Miller laryngoscope; chest compression; manikin; neonatal; LARYNGEAL MASK AIRWAY; PENTAX-AWS; PENTAX-AWS(R); ENDOTRACHEAL; PRESSURE; INFANTS;
D O I
10.1055/s-0034-1395482
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
Objective Recent guidelines for neonatal cardiopulmonary resuscitation emphasize the importance of adequate ventilation. In cases of failed resuscitation with positive pressure ventilation, tracheal intubation and chest compressions are recommended. The present study compared the utility of the Miller laryngoscope (Mil) and the videolaryngoscope Pentax-AWS Airway Scope (AWS; Hoya, Tokyo, Japan) with an infant or neonatal-sized Intlock (AWS-N; Pentax) during chest compressions on a neonatal manikin. Study Design A total of 23 novice doctors performed tracheal intubation on a neonatal manikin using the Mil and AWS-N, with or without chest compressions. Results In the Mil trials, all participants secured the airway without chest compressions, but nine failed with compressions (p < 0.001). In AWS-N trials, all participants succeeded regardless of whether chest compressions were performed or not. Intubation time was significantly longer with chest compressions with the Mil (p<0.001), but not with the AWS-N. Laryngoscopy difficulty, as assessed by a visual analog scale (VAS), increased significantly with chest compressions with the Mil, but not with the AWS-N, while the VAS for tube passage through the glottis increased with compressions with the Mil, but not with the AWS-N. Conclusion The AWS-N is an effective device for endotracheal intubation during chest compressions in neonatal simulations performed by novice doctors.
引用
收藏
页码:809 / 813
页数:5
相关论文
共 50 条
  • [21] Comparison of Pentax-AWS Airwayscope and Glidescope for Infant Tracheal Intubation by Anesthesiologists during Cardiopulmonary Arrest Simulation: A Randomized Crossover Trial
    Fujiwara, Shunsuke
    Komasawa, Nobuyasu
    Matsunami, Sayuri
    Okada, Daisuke
    Minami, Toshiaki
    BIOMED RESEARCH INTERNATIONAL, 2015, 2015
  • [22] Comparison of infant intubation through the TruView EVO2, TruView PCD, and Miller laryngoscope by paramedics during simulated infant cardiopulmonary resuscitation: A randomized crossover manikin study
    Szarpak, Lukasz
    Kurowski, Andrzej
    Czyzewski, Lukasz
    Madziala, Marcin
    Truszewski, Zenon
    AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2015, 33 (07): : 872 - 875
  • [23] Comparison of the Pentax, Truview, GlideScope, and the Miller laryngoscope for child intubation during resuscitation
    Szarpak, Lukasz
    Czyzewski, Lukasz
    Kurowski, Andrzej
    AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2015, 33 (03): : 391 - 395
  • [24] Randomized equivalence trial of the King Vision aBlade videolaryngoscope with the Miller direct laryngoscope for routine tracheal intubation in children &lt;2 yr of age
    Jagannathan, N.
    Hajduk, J.
    Sohn, L.
    Huang, A.
    Sawardekar, A.
    Albers, B.
    Bienia, S.
    De Oliveira, G. S.
    BRITISH JOURNAL OF ANAESTHESIA, 2017, 118 (06) : 932 - 937
  • [25] Three-day tracheal intubation manikin training for novice doctors using Macintosh laryngoscope, McGRATH MAC videolaryngoscope and Pentax AirwayScope
    Murakami, Yuryo
    Ueki, Ryusuke
    Niki, Miyuki
    Hirose, Munetaka
    Shimode, Noriko
    MEDICINE, 2021, 100 (04)
  • [26] Comparison of intubation through the McGrath MAC, GlideScope, AirTraq, and Miller Laryngoscope by paramedics during child CPR: a randomized crossover manikin trial
    Szarpak, Lukasz
    Karczewska, Katarzyna
    Evrin, Togay
    Kurowski, Andrzej
    Czyzewski, Lukasz
    AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2015, 33 (07): : 946 - 950
  • [27] Comparison of AirAngel® vs. Storz® videolaryngoscope and Macintosh® laryngoscope for endotracheal intubation training: prospective randomized crossover study
    Merter, Seyhmus
    Kayayurt, Kamil
    Kitapcioglu, Dilek
    Yaylaci, Serpil
    BMC MEDICAL EDUCATION, 2024, 24 (01)
  • [28] Comparison of the ease of tracheal intubation using a McGrath Mac videolaryngoscope and a standard Macintosh laryngoscope in normal airways A randomised trial
    Thion, Laurie-Anne
    Belze, Olivier
    Fischler, Marc
    Le Guen, Morgan
    EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2018, 35 (08) : 631 - 633
  • [29] Comparison of the McGrath MAC EMS Videolaryngoscope with a Conventional Laryngoscope for Standard and Difficult Airway Intubation: A Randomized, Cross-over, Simulation Trial
    Korkut, Semih
    Szarpak, Lukasz
    Evrin, Togay
    Smereka, Jacek
    Katipoglu, Burak
    Gorczyca, Damian
    EURASIAN JOURNAL OF EMERGENCY MEDICINE, 2019, 18 (04) : 211 - 217
  • [30] Appropriate shape of a stylet for tracheal intubation using the McGrath® MAC videolaryngoscope in neonates: a randomized crossover simulation study
    Masui, Katsuhide
    Tsunoda, Naoyuki
    Ito, Ayaka
    Asai, Takashi
    JA CLINICAL REPORTS, 2025, 11 (01):