Layer-specific residual deformations and uniaxial and biaxial mechanical properties of thoracic porcine aorta

被引:67
|
作者
Pena, Juan A. [1 ,2 ]
Martinez, Miguel A. [2 ,3 ]
Pena, Estefania [2 ,3 ]
机构
[1] Univ Zaragoza, Fac Engn & Architecture, Dept Management & Mfg Engn, E-50009 Zaragoza, Spain
[2] Univ Zaragoza, Dept Mech Engn, Aragon Inst Engn Res I3A, Appl Mech & Bioengn, E-50009 Zaragoza, Spain
[3] CIBER Bioingn Biomat & Nanomed CIBER BBN, Zaragoza, Spain
关键词
Uniaxial and biaxial testing; Thoracic aorta; Layer separation; Constitutive modeling; Elasticity; HUMAN CORONARY-ARTERIES; ABDOMINAL AORTAS; BEHAVIOR; COLLAGEN; WALL; PARAMETERS; STRESSES; ELASTIN; STRAIN; TISSUE;
D O I
10.1016/j.jmbbm.2015.05.024
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In this paper we hypothesize that the layer-separated residual stresses and mechanical properties of layer-separated thoracic aorta arteries may be dependent on arterial location of the vessel. To demonstrate any possible position differences, we measured the axial pre-stretch and opening angle and performed uniaxial and biaxial tests under physiological loads to study the mechanical behavior of both intact and layer-separated porcine aortic samples taken from thoracic region. In addition, we also provided constitutive parameters for each layer that can be used by biomedical engineers for investigating better therapies and developing artery-specific devices. We found that the opening angle for whole artery and adventitia layer are smaller and intima greater for proximal segments than for the distal thoracic ones. For the axial pre-stretch, our results showed significant increased values of the stretch ratios with location. We found that lower thoracic samples are stiffer than upper ones with the most important differences corresponding to those between the proximal and distal behaviors in the circumferential direction. The anisotropy represented by the different circumferential and longitudinal response is more remarkable in lower thoracic aorta. Finally, adventitia and intima samples present a tendency to be stiffer and more isotropic than the corresponding media samples in both directions for upper thoracic aorta and to be more anisotropic for lower thoracic aorta. (C) 2015 Elsevier Ltd. All rights reserved.
引用
收藏
页码:55 / 69
页数:15
相关论文
共 50 条
  • [41] EXPERIMENTAL DETERMINATION OF LAYER-SPECIFIC HYPERELASTIC PARAMETERS OF HUMAN DESCENDING THORACIC AORTAS
    Bozzo, Isabella
    Amabili, Marco
    Balasubramanian, Prabakaran
    Breslavsky, Ivan
    Ferrari, Giovanni
    PROCEEDINGS OF THE ASME INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION, 2019, VOL 9, 2020,
  • [42] An investigation of layer-specific tissue biomechanics of porcine atrioventricular valve anterior leaflets
    Kramer, Katherine E.
    Ross, Colton J.
    Laurence, Devin W.
    Babu, Anju R.
    Wu, Yi
    Towner, Rheal A.
    Mir, Arshid
    Burkhart, Harold M.
    Holzapfel, Gerhard A.
    Lee, Chung-Hao
    ACTA BIOMATERIALIA, 2019, 96 : 368 - 384
  • [43] Identification of circumferential regional heterogeneity of ascending thoracic aneurysmal aorta by biaxial mechanical testing
    Di Giuseppe, Marzio
    Alotta, Gioacchino
    Agnese, Valentina
    Bellavia, Diego
    Raffa, Giuseppe M.
    Vetri, Valeria
    Zingales, Massimiliano
    Pasta, Salvatore
    Pilato, Michele
    JOURNAL OF MOLECULAR AND CELLULAR CARDIOLOGY, 2019, 130 : 205 - 215
  • [44] Multilevel Signal Decomposition Layer-Specific Residual Network for Blade Icing Prediction
    Xiang, Dong
    Chen, Sizhuo
    Liu, Mengna
    Shi, Fan
    Cheng, Xu
    IEEE SIGNAL PROCESSING LETTERS, 2024, 31 : 2160 - 2164
  • [45] Region- and layer-specific investigations of the human menisci using SHG imaging and biaxial testing
    Rasheed, Bismi
    Ayyalasomayajula, Venkat
    Schaarschmidt, Ute
    Vagstad, Terje
    Schaathun, Hans Georg
    FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2023, 11
  • [46] UNIAXIAL AND BIAXIAL ORIENTATION DEVELOPMENT AND MECHANICAL-PROPERTIES OF POLYSTYRENE FILMS
    MATSUMOTO, K
    FELLERS, JF
    WHITE, JL
    JOURNAL OF APPLIED POLYMER SCIENCE, 1981, 26 (01) : 85 - 96
  • [47] The biaxial active mechanical properties of the porcine primary renal artery
    Zhou, Boran
    Rachev, Alexander
    Shazly, Tarek
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2015, 48 : 28 - 37
  • [48] Determinants of mechanical properties in the developing ovine thoracic aorta
    Wells, SM
    Langille, BL
    Lee, JM
    Adamson, SL
    AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 1999, 277 (04): : H1385 - H1391
  • [49] Experimental characterization of the biaxial mechanical properties of porcine gastric tissue
    Aydin, R. C.
    Brandstaeter, S.
    Braeu, F. A.
    Steigenberger, M.
    Marcus, R. P.
    Nikolaou, K.
    Notohamiprodjo, M.
    Cyron, C. J.
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2017, 74 : 499 - 506
  • [50] Mechanical properties of elastin along the thoracic aorta in the pig
    Lillie, M. A.
    Gosline, J. M.
    JOURNAL OF BIOMECHANICS, 2007, 40 (10) : 2214 - 2221