Layer-specific residual deformations and uniaxial and biaxial mechanical properties of thoracic porcine aorta

被引:67
|
作者
Pena, Juan A. [1 ,2 ]
Martinez, Miguel A. [2 ,3 ]
Pena, Estefania [2 ,3 ]
机构
[1] Univ Zaragoza, Fac Engn & Architecture, Dept Management & Mfg Engn, E-50009 Zaragoza, Spain
[2] Univ Zaragoza, Dept Mech Engn, Aragon Inst Engn Res I3A, Appl Mech & Bioengn, E-50009 Zaragoza, Spain
[3] CIBER Bioingn Biomat & Nanomed CIBER BBN, Zaragoza, Spain
关键词
Uniaxial and biaxial testing; Thoracic aorta; Layer separation; Constitutive modeling; Elasticity; HUMAN CORONARY-ARTERIES; ABDOMINAL AORTAS; BEHAVIOR; COLLAGEN; WALL; PARAMETERS; STRESSES; ELASTIN; STRAIN; TISSUE;
D O I
10.1016/j.jmbbm.2015.05.024
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In this paper we hypothesize that the layer-separated residual stresses and mechanical properties of layer-separated thoracic aorta arteries may be dependent on arterial location of the vessel. To demonstrate any possible position differences, we measured the axial pre-stretch and opening angle and performed uniaxial and biaxial tests under physiological loads to study the mechanical behavior of both intact and layer-separated porcine aortic samples taken from thoracic region. In addition, we also provided constitutive parameters for each layer that can be used by biomedical engineers for investigating better therapies and developing artery-specific devices. We found that the opening angle for whole artery and adventitia layer are smaller and intima greater for proximal segments than for the distal thoracic ones. For the axial pre-stretch, our results showed significant increased values of the stretch ratios with location. We found that lower thoracic samples are stiffer than upper ones with the most important differences corresponding to those between the proximal and distal behaviors in the circumferential direction. The anisotropy represented by the different circumferential and longitudinal response is more remarkable in lower thoracic aorta. Finally, adventitia and intima samples present a tendency to be stiffer and more isotropic than the corresponding media samples in both directions for upper thoracic aorta and to be more anisotropic for lower thoracic aorta. (C) 2015 Elsevier Ltd. All rights reserved.
引用
收藏
页码:55 / 69
页数:15
相关论文
共 50 条
  • [31] Characterization of Biaxial Mechanical Behavior of Porcine Aorta under Gradual Elastin Degradation
    Shahrokh Zeinali-Davarani
    Ming-Jay Chow
    Raphaël Turcotte
    Yanhang Zhang
    Annals of Biomedical Engineering, 2013, 41 : 1528 - 1538
  • [32] Characterization of Biaxial Mechanical Behavior of Porcine Aorta under Gradual Elastin Degradation
    Zeinali-Davarani, Shahrokh
    Chow, Ming-Jay
    Turcotte, Raphael
    Zhang, Yanhang
    ANNALS OF BIOMEDICAL ENGINEERING, 2013, 41 (07) : 1528 - 1538
  • [33] MECHANICAL PROPERTIES OF ASCENDING THORACIC AORTA OF MAN
    GOZNA, ER
    MARBLE, AE
    SHAW, AJ
    WINTER, DA
    CARDIOVASCULAR RESEARCH, 1973, 7 (02) : 261 - 265
  • [34] THE CIRCUMFERENTIAL MECHANICAL PROPERTIES OF BAMBOO WITH UNIAXIAL AND BIAXIAL COMPRESSION TESTS
    Jiang, Zehui
    Chen, Fuming
    Wang, Ge
    Liu, Xing'e
    Shi, Sheldon Q.
    Cheng, Hai-tao
    BIORESOURCES, 2012, 7 (04): : 4806 - 4816
  • [35] Effect of Aneurysm and Bicuspid Aortic Valve on Layer-Specific Ascending Aorta Mechanics
    Deveja, Rezar P.
    Iliopoulos, Dimitrios C.
    Kritharis, Eleftherios P.
    Angouras, Dimitrios C.
    Sfyris, Dimitrios
    Papadodima, Stavroula A.
    Sokolis, Dimitrios P.
    ANNALS OF THORACIC SURGERY, 2018, 106 (06): : 1692 - 1701
  • [36] Biaxial mechanical properties of the human thoracic and abdominal aorta, common carotid, subclavian, renal and common iliac arteries
    Alexey V. Kamenskiy
    Yuris A. Dzenis
    Syed A. Jaffar Kazmi
    Mark A. Pemberton
    Iraklis I. Pipinos
    Nick Y. Phillips
    Kyle Herber
    Thomas Woodford
    Robert E. Bowen
    Carol S. Lomneth
    Jason N. MacTaggart
    Biomechanics and Modeling in Mechanobiology, 2014, 13 : 1341 - 1359
  • [37] Biaxial mechanical properties of the human thoracic and abdominal aorta, common carotid, subclavian, renal and common iliac arteries
    Kamenskiy, Alexey V.
    Dzenis, Yuris A.
    Kazmi, Syed A. Jaffar
    Pemberton, Mark A.
    Pipinos, Iraklis I.
    Phillips, Nick Y.
    Herber, Kyle
    Woodford, Thomas
    Bowen, Robert E.
    Lomneth, Carol S.
    MacTaggart, Jason N.
    BIOMECHANICS AND MODELING IN MECHANOBIOLOGY, 2014, 13 (06) : 1341 - 1359
  • [38] Glycosaminoglycans modulate compressive stiffness and circumferential residual stress in the porcine thoracic aorta
    Ghadie, Noor M.
    Labrosse, Michel R.
    St-Pierre, Jean-Philippe
    ACTA BIOMATERIALIA, 2023, 170 : 556 - 566
  • [39] Capacitance of graphene bilayer as a probe of layer-specific properties
    Young, Andrea F.
    Levitov, Leonid S.
    PHYSICAL REVIEW B, 2011, 84 (08):
  • [40] Uniaxial and biaxial properties of terminally sterilized porcine urinary bladder matrix scaffolds
    Freytes, Donald O.
    Stoner, Richard M.
    Badylak, Stephen F.
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2008, 84B (02) : 408 - 414