In-depth evaluation of TOF-PET detectors based on crystal arrays and the TOFPET2 ASIC

被引:14
|
作者
Lamprou, Efthymios [1 ]
Sanchez, Filomeno [1 ]
Benlloch, Jose M. [1 ]
Gonzalez, Antonio J. [1 ]
机构
[1] Univ Politecn Valencia, CSIC, Ctr Mixto, Inst Instrumentac Imagen Mol I3M, Valencia 46022, Spain
基金
欧洲研究理事会;
关键词
TOF-PET; ASIC; Time walk; Crystal arrays; SiPM; Timing resolution; PS;
D O I
10.1016/j.nima.2020.164295
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
In recent years high efforts have been devoted to enhance spatial and temporal resolutions of PET detectors. However, accurately combining these two main features is, in most of the cases, challenging. Typically, a compromise has to be made between the number of readout channels, scintillator type and size, and photosensors arrangement if aiming for a good system performance, while keeping a moderate cost. In this work, we have studied several detector configurations for PET based on a set of 8x8 Silicon Photomultiplier (SiPMs) of 3x3 mm(2) active area, and LYSO crystal arrays with different pixel sizes. An exhaustive evaluation in terms of spatial, energy and timing resolution was made for all detector configurations. In some cases, when using pixel sizes different than SiPM active area, a significant amount of scintillation light may spread among several SiPMs. Therefore, we made use of a calibration method considering the different SiPM timing contributions. Best Detector Time Resolution (DTR) of 156 ps FWHM was measured when using 3x3 mm(2) crystal pixels directly coupled to the 3x3 mm(2) SiPMs. However, when using 1.5 mm crystal pixels with the same photosensor array, although we could clearly resolve all crystal pixels, an average DTR of 250 ps FWHM was achieved. We also shed light in this work on the timing dependency of the crystal pixel and photosensor alignment.
引用
收藏
页数:8
相关论文
共 47 条
  • [1] TOF-PET Detectors Based on ASIC Technology and Analog SiPMs
    Lamprou, Efthymios
    Gonzalez-Montoro, Andrea
    Canizares, Gabriel
    Ilisie, Victor
    Sanchez, Filomeno
    Freire, Marta
    Hernandez, Liczandro
    Vidal, Luis F.
    Barrio, John
    Gonzalez, Antonio J.
    Benlloch, Jose M.
    2018 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE PROCEEDINGS (NSS/MIC), 2018,
  • [2] Characterization of a Compton camera based on the TOFPET2 ASIC
    Viegas, R.
    Roser, J.
    Barrientos, L.
    Borja-Lloret, M.
    Casana, J., V
    Garcia Lopez, J.
    Jimenez-Ramos, M. C.
    Hueso-Gonzalez, F.
    Ros, A.
    Llosa, G.
    RADIATION PHYSICS AND CHEMISTRY, 2023, 202
  • [3] Preliminary Characterization of ASIC-Based Detectors for TOF-PET Applications
    Aguilar, Albert
    Monzo, Jose M.
    Gonzalez, Antonio J.
    Gonzalez-Montoro, Andrea
    Canizares, Gabriel
    Vidal, Luis F.
    Hernandez, Liczandro
    Colom, Ricardo
    Grau-Ruiz, Daniel
    Lamprou, Efthimis
    Rigla, Juan P.
    Diaz-Caballero, Elena
    Garcia-Garrigos, Juan J.
    Bellido, Pablo
    Conde, Pablo
    Iborra, Amadeo
    Moliner, Laura
    Rodriguez-Alvarez, Maria J.
    Sanchez, Sebastian
    Seimetz, Michael
    Soriano, Antonio
    Sanchez, Filomeno
    Benlloch, Jose M.
    2016 IEEE NUCLEAR SCIENCE SYMPOSIUM, MEDICAL IMAGING CONFERENCE AND ROOM-TEMPERATURE SEMICONDUCTOR DETECTOR WORKSHOP (NSS/MIC/RTSD), 2016,
  • [4] Evaluation of high-resolution and depth-encoding PET detector modules based on single-ended readout with TOFPET2 ASIC
    Wang, Mingchen
    Wang, Yonggang
    Wang, Liwei
    RADIATION DETECTION TECHNOLOGY AND METHODS, 2021, 5 (03) : 451 - 458
  • [5] Evaluation of high-resolution and depth-encoding PET detector modules based on single-ended readout with TOFPET2 ASIC
    Mingchen Wang
    Yonggang Wang
    Liwei Wang
    Radiation Detection Technology and Methods, 2021, 5 : 451 - 458
  • [6] Initial Measurements with the PETsys TOFPET2 ASIC Evaluation Kit and a Characterization of the ASIC TDC
    Schug, David
    Nadig, Vanessa
    Weissler, Bjoern
    Gebhardt, Pierre
    Schulz, Volkmar
    IEEE TRANSACTIONS ON RADIATION AND PLASMA MEDICAL SCIENCES, 2019, 3 (04) : 444 - 453
  • [7] Evaluation of the PETsys TOFPET2 ASIC in multi-channel coincidence experiments
    Nadig, Vanessa
    Schug, David
    Weissler, Bjoern
    Schulz, Volkmar
    EJNMMI PHYSICS, 2021, 8 (01)
  • [8] Evaluation of the PETsys TOFPET2 ASIC in multi-channel coincidence experiments
    Vanessa Nadig
    David Schug
    Bjoern Weissler
    Volkmar Schulz
    EJNMMI Physics, 8
  • [9] On the Combination of a Dedicated HF Readout Circuit and the TOFPET2 ASIC to Push the Timing Performance of PET Systems
    Nadig, V.
    Gundacker, S.
    Radermacher, H.
    Schug, D.
    Weissler, B.
    Schulz, V.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2021, 48 (SUPPL 1) : S490 - S491
  • [10] Performance evaluation of the FastIC readout ASIC with emphasis on Cherenkov emission in TOF-PET
    Piller, Markus
    Castilla, Antonio M.
    Terragni, Giulia
    Alozy, Jerome
    Auffray, Etiennette
    Ballabriga, Rafael
    Campbell, Michael
    Deutschmann, Bernd
    Gascon, David
    Gola, Alberto
    Merzi, Stefano
    Michalowska-Forsyth, Alicja
    Penna, Michele
    Gomez, Sergio
    Kratochwil, Nicolaus
    PHYSICS IN MEDICINE AND BIOLOGY, 2024, 69 (11):