Helical tomotherapy for the treatment of anal canal cancer: a dosimetric comparison with 3D conformal radiotherapy

被引:7
|
作者
Ugurluer, Gamze [1 ]
Ballerini, Giorgio [1 ]
Moeckli, Raphael [2 ]
Matzinger, Oscar [1 ]
Bourhis, Jean [1 ]
Ozsahin, Mahmut [1 ]
机构
[1] Univ Lausanne, Univ Hosp Ctr, Dept Radiat Oncol, Lausanne, Switzerland
[2] Univ Lausanne, Univ Hosp Ctr, Inst Radiat Phys, Lausanne, Switzerland
关键词
Anal canal cancer; 3D Conformal radiotherapy; Helical tomotherapy; MODULATED RADIATION-THERAPY; TRIAL ACT I; FOLLOW-UP; RTOG; 0529; CARCINOMA; IMRT; MITOMYCIN; CHEMORADIATION; FLUOROURACIL; CHEMOTHERAPY;
D O I
10.5301/tj.5000269
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Aims and Background: The standard treatment of anal canal cancer (ACC) is combined chemotherapy and radiation therapy (RT), which is complex because of the shape of the target volumes and the need to minimize the irradiation of normal pelvic structures. In this study we compared the dosimetric results of helical tomotherapy (HT) plans with traditional 3D conformal RT (3DRT) plans for the treatment of ACC. Methods and Study design: Twelve patients (median age 57 years, range 38-83; F/M 8/4) treated with HT and concurrent chemotherapy for locally advanced ACC were selected. All had histologically confirmed squamous-cell carcinoma. A clinical target volume including the tumor and pelvic and inguinal lymph nodes was treated with HT to a total dose of 36 Gy in 1.8-Gy daily fractions. Then a sequential boost of 23.4 Gy in 1.8-Gy daily fractions (total dose 59.4 Gy) was delivered to the tumor and involved nodes. For all 12 patients, 3DRT plans were generated for comparison. Treatment plans were evaluated by means of standard dose-volume histograms. Dose coverage of the planning target volumes (PTVs), homogeneity index (HI), and mean doses to organs at risk (OARs) were compared. Results: The coverage of PTV was comparable between the two treatment plans. HI was better in the HT vs. 3DRT plans (1.25 and 3.57, respectively; p<0.0001). HT plans resulted in better sparing of OARs (p<0.0001). Conclusions: HT showed superior target dose conformality and significant sparing of pelvic structures compared with 3DRT. Further investigation should determine if these dosimetric improvements will improve clinical outcomes regarding locoregional control, survival, and treatment-related acute and late morbidity.
引用
收藏
页码:268 / 272
页数:5
相关论文
共 50 条
  • [1] Helical tomotherapy (HT) for the treatment of anal canal cancer: preliminary clinical results, and dosimetric comparison between HT and intensity-modulated or 3D conformal radiotherapy
    Ugurluer, G.
    Ballerini, G.
    Letenneur, G.
    Lacombe, C.
    Pissaturo, O.
    Matzinger, O.
    Montemurro, M.
    Zouhair, A.
    Mirimanoff, R. O.
    Ozsahin, M.
    [J]. EJC SUPPLEMENTS, 2009, 7 (02): : 331 - 331
  • [2] Dosimetric Comparison of a Simple Helical Tomotherapy Technique and 3D Conformal Radiotherapy for the Treatment of Left-sided Breast Cancer
    Yassa, M.
    Hijal, T.
    Abrous, S.
    Giraud, P.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2010, 78 (03): : S818 - S818
  • [3] Comparison of intensity modulated radiotherapy and 3D conformal radiotherapy in patients with cancer of anal canal
    Mihaylova, I.
    Gesheva, N.
    Parvanova, V.
    Chakarova, A.
    Dimitrova, N.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2014, 111 : S79 - S79
  • [4] Simultaneous Integrated Boost in the Treatment of Breast Cancer: A Dosimetric Comparison of Helical Tomotherapy (HT) and Three-dimensional Conformal Radiotherapy (3D CRT)
    Hijal, T.
    Castro-Pena, P.
    Fournier-Bidoz, N.
    Kirova, Y.
    Zcfkili, S.
    Bollet, M.
    Dendale, R.
    Campana, F.
    Fourquet, A.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2009, 75 (03): : S725 - S726
  • [5] A Comparison of Radiotherapy Treatment Plans for Hodgkin Lymphoma using 3D Conformal and Helical Tomotherapy Methods
    Rahman, F.
    Fairfoul, J.
    Williams, M. V.
    Burnet, N. G.
    [J]. CLINICAL ONCOLOGY, 2011, 23 (03) : S49 - S49
  • [6] Comparison of four 3D conformal treatment techniques to optimise radiotherapy treatment for anal cancer
    Cray, Alison
    Markham, Cathy
    Ryan, Michelle
    Herschtal, Alan
    Ngan, Samuel Y.
    Chander, Sarat
    [J]. JOURNAL OF MEDICAL RADIATION SCIENCES, 2014, 61 (04) : 253 - 260
  • [7] Hypofractionated Helical Tomotherapy for breast cancer Vs prone 3D-conformal radiotherapy: A dosimetric analysis
    Giugliano, F.
    Iadanza, L.
    Falivene, S.
    Borzillo, V.
    Cammarota, F.
    Muto, M.
    Ravo, V.
    Di Franco, R.
    Muto, P.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2014, 111 : S52 - S52
  • [8] Treatment planning comparison of fractionated stereotactic radiotherapy, 3D conformal radiotherapy, and helical tomotherapy for benign tumours in the base of skull
    Cheung, A.
    Malone, S.
    Szanto, J.
    Clark, B.
    MacPherson, M.
    Nyiri, B.
    Fox, G.
    Montgomery, L.
    Carty, K.
    Deshaies, Y.
    Zohr, R.
    Spaans, J.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2006, 80 : S27 - S28
  • [9] Helical tomotherapy in the treatment of anal canal cancer: Preliminary results
    Ozsahin, M.
    Pachoud, M.
    Moeckli, R.
    Letenneur, G.
    Lacombe, C.
    Montemurro, M.
    Betz, M.
    Matzinger, O.
    Mirimanoff, R. O.
    Zouhair, A.
    [J]. JOURNAL OF CLINICAL ONCOLOGY, 2008, 26 (15)
  • [10] HELICAL TOMOTHERAPY IN THE TREATMENT OF ANAL CANAL CANCER: PRELIMINARY RESULTS
    Ozsahin, M.
    Pachoud, M.
    Moeckli, R.
    Letenneur, G.
    Lacombe, C.
    Mirimanoff, R. O.
    Zouhair, A.
    [J]. STRAHLENTHERAPIE UND ONKOLOGIE, 2008, 184 (11) : 625 - 625