Comparison of EMI Signatures to Improve Condition Assessment of Generator Stator Insulation

被引:0
|
作者
Timperley, James E. [1 ]
Vallejo, Jose M. [2 ]
机构
[1] Doble Engn, Doble Power Serv, Galloway, OH 43119 USA
[2] Univ Star Egy Serv, Consult & Test Serv, Houston, TX USA
关键词
EMI Diagnostics; generator condition assessment; on line testing; loose stator windings;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
An important benefit of EMI (Electromagnetic Interference) Diagnostics when applied to identical generators is that the EMI Signatures can be directly compared to better assess the overall health of these machines. This capability allows an accurate ranking of any generator deterioration that may be present and in turn provides critical information to help optimize maintenance practices. Trending data is discussed. Examples of two load tests on several generators are presented. This technique detects loose components. The examples shown include machines with loose windings and tight windings. Comparison of the EMI signatures between similar generators is provided with explanation. Only the verified results of field tests on operating generators are presented.
引用
收藏
页码:281 / 284
页数:4
相关论文
共 50 条
  • [1] Condition Assessment of Generator Stator Insulation by Dc Ramp and IR Tests
    Naranpanawe, W. M. L. B.
    Rathnayake, R. M. H. M.
    Fernando, M. A. R. M.
    Jayantha, G. A.
    [J]. 2013 8TH IEEE INTERNATIONAL CONFERENCE ON INDUSTRIAL AND INFORMATION SYSTEMS (ICIIS), 2013, : 174 - +
  • [2] Assessment of insulation condition of generator stator bars based on velocity of ultrasonic waves
    Hao, YP
    Xie, HK
    Wang, GL
    Jia, ZD
    [J]. IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2003, 10 (03) : 539 - 547
  • [3] Assessment of insulation condition of hydro generator stator bars after 40 years in service
    Klamt, Thomas
    Hillmer, Thomas
    Vannay, Francois
    [J]. 2011 ELECTRICAL INSULATION CONFERENCE (EIC), 2011, : 244 - 248
  • [4] GENERATOR CONDITION ASSESSMENT THROUGH EMI DIAGNOSTICS
    Timperley, James E.
    [J]. PROCEEDINGS OF THE ASME POWER CONFERENCE 2008, 2008, : 349 - 354
  • [5] Turbo generator stator winding condition assessment
    Arshad, M
    Khaliq, A
    Islam, SM
    [J]. 2004 International Conference on Power System Technology - POWERCON, Vols 1 and 2, 2004, : 1399 - 1403
  • [6] Assessment of 300MW Turbine Generator Stator Insulation
    Wang, Lijun
    Zhang, Yizhong
    Jin, Wenjing
    Shi, Jingzhe
    Zhou, Song
    Li, Qiang
    Liu, Song
    [J]. PROCEEDINGS OF 2014 INTERNATIONAL SYMPOSIUM ON ELECTRICAL INSULATING MATERIALS (ISEIM 2014), 2014, : 500 - 502
  • [7] Condition Evaluation of Large Generator Stator Insulation Based on Partial Discharge Measurement
    Li, Ruihua
    Pan, Ling
    Yan, Chen
    Li, Hao
    Hu, Bo
    [J]. ADVANCES IN MECHANICAL ENGINEERING, 2013,
  • [8] Condition Evaluation of Stator Winding Insulation of Vintage High Voltage Turbine Generator
    Kumar, P. G. S.
    Reddy, K. Malla
    [J]. 2015 IEEE INTERNATIONAL CONFERENCE ON ELECTRICAL, COMPUTER AND COMMUNICATION TECHNOLOGIES, 2015,
  • [9] Condition Assessment of Generator Insulation using Diagnostic Tests
    Chophel, Tenzin
    Suwanasri, Thanapong
    Suwanasri, Cattareya
    [J]. 2019 7TH INTERNATIONAL ELECTRICAL ENGINEERING CONGRESS (IEECON 2019), 2019,
  • [10] Condition Assessment of Stator Insulation during Drying, Wetting and Electrical Ageing
    Fernando, M. A. R. M.
    Naranpanawa, W. M. L. B.
    Rathnayake, R. M. H. M.
    Jayantha, G. A.
    [J]. IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2013, 20 (06) : 2081 - 2090