Reproducibility of normalized apparent diffusion coefficient measurements on 3.0-T diffusion-weighted imaging of normal pancreas in a healthy population

被引:8
|
作者
Ding, Xun [1 ]
Xu, Haibo [1 ]
Zhou, Jun [1 ]
Xu, Jia [1 ]
Mei, Hao [1 ]
Long, Qingyun [1 ]
Wang, Yaxun [1 ]
机构
[1] Wuhan Univ, Dept Med Imaging, Zhongnan Hosp, Wuhan 430071, Hubei, Peoples R China
关键词
normalized apparent diffusion coefficient; pancreas; reproducibility; CYSTIC-FIBROSIS; MRI; LESIONS; VALUES; MASS;
D O I
10.1097/MD.0000000000015104
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
To prospectively compare the reproducibility of normal pancreas-normalized apparent diffusion coefficient (ADC) measurements for the normal pancreas and mean normalized ADCs at different pancreas anatomic locations. In total, 22 healthy volunteers underwent pancreatic 3.0-T magnetic resonance (MR) imaging, including axial diffusion-weighted (DW) imaging with 3 b values used (0, 400, and 800s/mm(2)) and with the respiratory-triggered (RT) technique. The mean ADCs from 3 regions of interest (ROIs) in 5 anatomic locations (head [H], body [B], and tail [T] of pancreas and spleen [S] and erector spinae muscles [M]) were calculated. The pancreas-normalized ADC was defined as the ratio of the ADC for the pancreas to the ADC for the spleen or erector spinae muscle. Reproducibility of ADCs and normalized ADCs was assessed by the Bland-Altman method. The ADC and normalized ADC data were analyzed by repeated-measures ANOVA. Mean ADC and normalized ADC values did not differ (P >. 05) with repeated measurements at the different pancreas anatomic locations. Reproducibility of pancreas-normalized ADC measurements in each of the 3 pancreatic anatomic locations was better with the erector spinae muscle rather than the spleen used as a reference. Mean ADC and normalized ADC values significantly differed between the 3 pancreatic segments (H: 1.36 x 10(-3) mm(2)/s, B: 1.38 x 10(-3) mm(2)/s, T: 1.25 x 10(-3) mm(2)/s, P=.022; H/S: 1.75, B/S: 1.78, T/S: 1.59, P=.009; H/M: 0.91, B/M: 0.95, T/M: 0.85, P=.008). Mean ADC values and normalized ADC values showed a trend to decrease from the pancreatic head to tail. Our preliminary results suggest that normalized ADC measurements for the pancreas show good intra-and interobserver reproducibility, the erector spinae muscle is a better choice than the spleen for calculating normalized ADC values for the pancreas, and the normalized ADC values are lower for the pancreatic tail than other pancreatic segments.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Short- and Midterm Reproducibility of Apparent Diffusion Coefficient Measurements at 3.0-T Diffusion-weighted Imaging of the Abdomen
    Braithwaite, Adam C.
    Dale, Brian M.
    Boll, Daniel T.
    Merkle, Elmar M.
    RADIOLOGY, 2009, 250 (02) : 459 - 465
  • [2] Apparent Diffusion Coefficient Reproducibility of the Pancreas Measured at Different MR Scanners Using Diffusion-Weighted Imaging
    Ye, Xiao-Hua
    Gao, Jia-Yin
    Yang, Zheng-Han
    Liu, Yuan
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2014, 40 (06) : 1375 - 1381
  • [3] Diffusion-Weighted Imaging of the Abdomen at 3.0 Tesla: Image Quality and Apparent Diffusion Coefficient Reproducibility Compared With 1.5 Tesla
    Rosenkrantz, Andrew B.
    Oei, Marcel
    Babb, James S.
    Niver, Benjamin E.
    Taouli, Bachir
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2011, 33 (01) : 128 - 135
  • [4] Diffusion-weighted MRI of the normal adult pancreas: The effect of age on apparent diffusion coefficient values
    Ma, C.
    Pan, C. -S.
    Zhang, H. -G.
    Wang, H.
    Wang, J.
    Chen, S. -Y.
    Lu, J. -P.
    CLINICAL RADIOLOGY, 2013, 68 (10) : E532 - E537
  • [5] Perfusion bias in the apparent diffusion coefficient measurements of diffusion-weighted magnetic resonance imaging
    Priola, Adriano M.
    Veltri, Andrea
    Priola, Sandro M.
    TUMORI JOURNAL, 2018, 104 (04): : 315 - 315
  • [6] Diffusion weighted imaging of the normal breast: reproducibility of apparent diffusion coefficient measurements and variation with menstrual cycle and menopausal status
    Elizabeth A. M. O’Flynn
    Veronica A. Morgan
    Sharon L. Giles
    Nandita M. deSouza
    European Radiology, 2012, 22 : 1512 - 1518
  • [7] Diffusion weighted imaging of the normal breast: reproducibility of apparent diffusion coefficient measurements and variation with menstrual cycle and menopausal status
    O'Flynn, Elizabeth A. M.
    Morgan, Veronica A.
    Giles, Sharon L.
    deSouza, Nandita M.
    EUROPEAN RADIOLOGY, 2012, 22 (07) : 1512 - 1518
  • [8] Apparent diffusion coefficient normalization of normal liver Will it improve the reproducibility of diffusion-weighted imaging at different MR scanners as a new biomarker?
    Zhu, Jie
    Zhang, Jie
    Gao, Jia-Yin
    Li, Jin-Ning
    Yang, Da-Wei
    Chen, Min
    Zhou, Cheng
    Yang, Zheng-Han
    MEDICINE, 2017, 96 (03)
  • [9] Evaluation of apparent diffusion coefficient measurements of brain injury in type 2 diabetics with retinopathy by diffusion-weighted MRI at 3.0 T
    Wang, Zhongling
    Lu, Ziwei
    Li, Jing
    Pan, Changjie
    Jia, Zhongzhi
    Chen, Hanqi
    Ge, Xiaomin
    NEUROREPORT, 2017, 28 (02) : 69 - 74
  • [10] Preliminary Experience of 5.0 T Higher Field Abdominal Diffusion-Weighted MRI: Agreement of Apparent Diffusion Coefficient With 3.0 T Imaging
    Zhang, Yunfei
    Yang, Chun
    Liang, Liang
    Shi, Zhang
    Zhu, Shuo
    Chen, Caizhong
    Dai, Yongming
    Zeng, Mengsu
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2022, 56 (04) : 1009 - 1017