Characterisation of a clothing material for gamma dosimetry in mixed neutron-gamma fields

被引:0
|
作者
Benabdesselam, M
Iacconi, P
Lapraz, D
Serbat, A
Dhermain, J
Laugier, J
机构
关键词
D O I
10.1093/oxfordjournals.rpd.a031996
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
When an irradiation accident occurs, it is very important for medical treatment to be able to reconstruct the cartography of the dose absorbed by the irradiated person. A cotton textile coated with an or-alumina dosimetric powder is suitable to clothe persons subjected to irradiation risks. With some precautions, the dose may be measured by thermoluminescence (TL). Responses of the aluminised cotton textile relative to the absorbed dose are shown for different ratios of DJD, and relative to the photon energy.
引用
收藏
页码:461 / 465
页数:5
相关论文
共 50 条
  • [1] Dosimetry in mixed neutron-gamma fields with a Timepix detector
    Rubovic, Peter
    Ekendahl, Daniela
    Vykydal, Zdenek
    Hulka, Jiri
    Bergmann, Benedikt
    Pospisil, Stanislav
    Stekl, Ivan
    RADIATION MEASUREMENTS, 2018, 119 : 22 - 26
  • [2] DOSIMETRY OF MIXED NEUTRON-GAMMA FIELDS WITH SOLID STATE DETECTORS
    TOCHILIN, E
    RADIATION RESEARCH, 1969, 39 (02) : 548 - &
  • [3] DOSIMETRY IN MIXED NEUTRON-GAMMA FIELDS - THE NEUTRON SENSITIVITIES OF GEIGER-MULLER COUNTERS
    JONES, DTL
    SOUTH AFRICAN JOURNAL OF SCIENCE, 1987, 83 (03) : 178 - 179
  • [4] MIXED-FIELD NEUTRON-GAMMA DOSIMETRY WITH AN ELECTRONIC PERSONAL GAMMA DOSIMETER
    Waller, Edward J.
    Brown, Jason T.
    NUCLEAR TECHNOLOGY, 2011, 175 (01) : 93 - 104
  • [5] Application of thermoluminescent dosimeters to mixed neutron-gamma dosimetry for BNCT
    Kessler, C
    Stecher-Rasmussen, F
    Rassow, J
    Garbe, S
    Sauerwein, W
    FRONTIERS IN NEUTRON CAPTURE THERAPY, VOLS 1 AND 2, 2001, : 1165 - 1173
  • [6] Qualification of specially prepared clothing material for gamma dosimetry: Application to mixed neutron-photon radiation fields
    Benabdesselam, M
    Iacconi, P
    Lapraz, D
    Serbat, A
    Laugier, J
    Dhermain, J
    RADIATION PROTECTION DOSIMETRY, 1996, 66 (1-4) : 125 - 128
  • [7] OPTIMIZATION OF ELECTRET IONIZATION-CHAMBER FOR DOSIMETRY IN MIXED NEUTRON-GAMMA RADIATION-FIELDS
    DORSCHEL, B
    PRETZSCH, G
    RADIATION PROTECTION DOSIMETRY, 1984, 9 (01) : 43 - 47
  • [8] MEASURING FAST-NEUTRON FLUXES IN MIXED NEUTRON-GAMMA FIELDS
    KRONENBERG, S
    NUCLEONICS, 1963, 21 (03): : 78 - &
  • [9] A multicomponent dosimetry system for neutron-gamma mixed field monitoring in BNCT
    Angelucci, M
    Borio, R
    Chiocchini, S
    Degli Esposti, P
    Forini, N
    Salvadori, P
    PHYSICA MEDICA, 1999, 15 (03) : 131 - 136
  • [10] GEIGER-MUELLER COUNTER FOR MIXED NEUTRON-GAMMA BEAM DOSIMETRY
    MCDONALD, JC