Characterisation of a clothing material for gamma dosimetry in mixed neutron-gamma fields

被引:0
|
作者
Benabdesselam, M
Iacconi, P
Lapraz, D
Serbat, A
Dhermain, J
Laugier, J
机构
关键词
D O I
10.1093/oxfordjournals.rpd.a031996
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
When an irradiation accident occurs, it is very important for medical treatment to be able to reconstruct the cartography of the dose absorbed by the irradiated person. A cotton textile coated with an or-alumina dosimetric powder is suitable to clothe persons subjected to irradiation risks. With some precautions, the dose may be measured by thermoluminescence (TL). Responses of the aluminised cotton textile relative to the absorbed dose are shown for different ratios of DJD, and relative to the photon energy.
引用
收藏
页码:461 / 465
页数:5
相关论文
共 50 条
  • [41] Discrete Fourier Transform Method for Discrimination of Digital Scintillation Pulses in Mixed Neutron-Gamma Fields
    Safari, M. J.
    Davani, F. Abbasi
    Afarideh, H.
    Jamili, S.
    Bayat, E.
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2016, 63 (01) : 325 - 332
  • [42] FAST NEUTRON-GAMMA DISCRIMINATOR
    BETZ, P
    BRAUN, G
    HAMMEL, G
    URBAN, J
    NUCLEAR INSTRUMENTS & METHODS, 1974, 119 (01): : 199 - 203
  • [43] A compact neutron-gamma spectrometer
    Cester, D.
    Nebbia, G.
    Stevanato, L.
    Pino, F.
    Sajo-Bohus, L.
    Viesti, G.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2013, 719 : 81 - 84
  • [44] AN ENVIRONMENTAL NEUTRON-GAMMA MONITOR
    HERBAUT, Y
    LEROUX, JB
    RADIOPROTECTION, 1984, 19 (01) : 73 - 77
  • [45] STILBENE SCINTILLATION SPECTROMETER AS A MIXED NEUTRON-GAMMA RADIATION DOSIMETER
    KOVALEV, VP
    KAPCHIGA.SP
    PAVLOV, LP
    ATOMNAYA ENERGIYA, 1973, 34 (01): : 7 - 10
  • [46] A HEXAFLUOROBENZENE GAMMA DOSIMETER FOR USE IN MIXED NEUTRON AND GAMMA FIELDS
    WAIT, GD
    NUCLEAR APPLICATIONS, 1968, 4 (06): : 440 - +
  • [47] NEUTRON-GAMMA MIXED FIELD DOSIMETRY USING A 6LiF:Mg,Cu,P THERMOLUMINESCENT DOSIMETER
    Sadeghi, Ehsan
    Zahedifar, Mostafa
    Rezaii, Parasto
    NUCLEAR TECHNOLOGY & RADIATION PROTECTION, 2021, 36 (04): : 346 - 351
  • [48] UTILIZATION OF MINIATURE SILICON PHOTODIODES IN DOSIMETRY OF NEUTRON-GAMMA RADIATION-FIELD
    BURIAN, A
    PETR, I
    VIRAGH, E
    ZSOLNAY, EM
    KERNENERGIE, 1986, 29 (09): : 342 - 344
  • [49] EPR dosimetry in a mixed neutron and gamma radiation field
    Trompier, F
    Fattibene, P
    Tikunov, D
    Bartolotta, A
    Carosi, A
    Doca, MC
    RADIATION PROTECTION DOSIMETRY, 2004, 110 (1-4) : 437 - 442