Gas hold-up in three phase co-current bubble columns

被引:27
|
作者
Kumar, S. [1 ]
Kumar, R. A. [1 ]
Munshi, P. [2 ]
Khanna, A. [1 ]
机构
[1] IIT Kanpur, Dept Chem Engn, Kanpur 208016, UP, India
[2] IIT Kanpur, Dept Mech Engn, Kanpur 208016, UP, India
来源
CHISA 2012 | 2012年 / 42卷
关键词
Bubble column; three phase flow; solid effect; co-current flows; gas hold-up; LIQUID-SOLID SUSPENSIONS; FLOW REGIME TRANSITION; ELEVATED PRESSURE; SLURRY CONCENTRATIONS; SPARGED REACTORS; RISE VELOCITY; HEAT-TRANSFER; HYDRODYNAMICS; DESIGN; TEMPERATURE;
D O I
10.1016/j.proeng.2012.07.470
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Bubble columns are used in a large number of applications in chemical engineering. The important variables that affect the gas holdup, bubble dynamics and flow regime in a bubble column are gas and liquid velocities, liquid viscosity, liquid surface tension, design of the gas distributor, solid concentration and column diameter. Experiments have been performed in a 15 cm diameter co-current slurry bubble column with liquid phase as water and air as the gas phase. Glass beads of mean diameter 35 mu m have been used as solid phase. Solid loading up to 9% has been used. The superficial gas velocity varies from 1.0 to 16.28 cm/s and superficial liquid velocity varies from 0 to 12.26 cm/s. Effects of liquid height, liquid velocity, gas velocity and solid concentration over gas holdup for both two and three phase co-current flows have been studied. For batch case the liquid height didn't affect the gas holdup. The gas holdup increases with increase in gas velocity for both two and three phase co-current columns. For two phase and three phase flow up to 1% solid loading; at low superficial gas velocity i.e. in the homogeneous regime, the increase in liquid velocity doesn't show any change in the gas holdup. For higher gas velocities i.e. in the heterogeneous regime, increase in liquid velocity decreases the gas holdup rapidly. Above 1% solid loading, liquid velocity effect over gas hold-up is negligible. With increase in solid concentration for co-current bubble column the gas holdup slightly increases or remains constant up to 5% loading; beyond this loading there is a significant decrease in gas holdup. (C) 2012 Published by Elsevier Ltd.
引用
收藏
页码:782 / 794
页数:13
相关论文
共 50 条
  • [41] Gas hold-up in bubble columns: influence of alcohol addition versus operation at elevated pressures
    Krishna, R
    Urseanu, MI
    Dreher, AJ
    CHEMICAL ENGINEERING AND PROCESSING-PROCESS INTENSIFICATION, 2000, 39 (04) : 371 - 378
  • [42] LIQUID CIRCULATION PATTERNS AND THEIR EFFECT ON GAS HOLD-UP AND AXIAL MIXING IN BUBBLE-COLUMNS
    WALTER, JF
    BLANCH, HW
    CHEMICAL ENGINEERING COMMUNICATIONS, 1983, 19 (4-6) : 243 - 262
  • [43] Gamma ray tomography-An experimental analysis of fractional gas hold-up in bubble columns
    Patel, Ashutosh K.
    Thorat, Bhaskar N.
    Chemical Engineering Journal, 2008, 137 (02): : 376 - 385
  • [45] Volumetric mass transfer coefficient and gas hold-up in highly viscous liquid in bubble columns
    Tokanai, H
    Harada, E
    Kuriyama, M
    KAGAKU KOGAKU RONBUNSHU, 2001, 27 (06) : 792 - 798
  • [46] Gas hold-up in bubble columns: Operation with concentrated slurries versus high viscosity liquid
    Krishna, R
    Urseanu, MI
    de Swart, JWA
    Ellenberger, J
    CANADIAN JOURNAL OF CHEMICAL ENGINEERING, 2000, 78 (03): : 442 - 448
  • [47] Estimation of gas hold-up in bubble columns using wall pressure fluctuations and machine learning
    Ranade, Vivek V.
    Marchini, Sara
    Kipping, Ragna
    V. Ranade, Nanda
    Schubert, Markus
    CHEMICAL ENGINEERING JOURNAL, 2024, 500
  • [48] Effect of sparger design and height to diameter ratio on fractional gas hold-up in bubble columns
    Thorat, B.N.
    Chemical Engineering Research and Design, 1998, 76 (A7): : 823 - 834
  • [49] Gas hold-up estimation in bubble columns using passive acoustic waveforms with neural networks
    Al-Masry, Waheed A.
    Abdennour, Adel
    JOURNAL OF CHEMICAL TECHNOLOGY AND BIOTECHNOLOGY, 2006, 81 (06) : 951 - 957
  • [50] The effect of gas-liquid counter-current operation on gas hold-up in bubble columns using electrical resistance tomography
    Jin, Haibo
    Yang, Suohe
    He, Guangxiang
    Wang, Mi
    Williams, R. A.
    JOURNAL OF CHEMICAL TECHNOLOGY AND BIOTECHNOLOGY, 2010, 85 (09) : 1278 - 1283