Small-Signal Modeling of Digitally Controlled Grid-Connected Inverters With LCL Filters

被引:111
|
作者
Zhang, Xiaotian [1 ]
Spencer, Joseph W. [1 ]
Guerrero, Josep M. [2 ]
机构
[1] Univ Liverpool, Dept Elect Engn & Elect, Liverpool L69 3GJ, Merseyside, England
[2] Aalborg Univ, Dept Energy Technol, DK-9220 Aalborg, Denmark
关键词
Average models; digital control; grid-connected inverters; z-domain models; VOLTAGE-SOURCE; DESIGN; FEEDFORWARD; DISTORTION; REDUCTION; STABILITY;
D O I
10.1109/TIE.2012.2204713
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
When LCL filters are applied to digitally controlled grid-connected inverters, the design of controllers is usually implemented using classic average models. The accuracy of these models in s-domain is only guaranteed in low-frequency range. In order to predict the dynamic behaviors, new small-signal z-domain models are deduced for digitally controlled grid-connected inverters with converter current control scheme and converter current plus grid current control scheme. The proposed methods model the inverters including different delay effects under most possible circumstances, which allows direct design for controllers in z-domain. The stability boundaries obtained from the root loci of the classic average models and the proposed z-domain models and the discrete state-space models are compared to the simulation results, showing that the proposed z-domain models are more effective in predicting instabilities. Experimental results are presented and compared to the average models predictions and z-domain models predictions, which shows the proposed models are capable of predicting the values of control variables at the true sampling instants.
引用
收藏
页码:3752 / 3765
页数:14
相关论文
共 50 条
  • [21] Design of LCL-Filters with LCL Resonance Frequencies beyond the Nyquist Frequency for Grid-Connected Inverters
    Tang, Yi
    Yao, Wenli
    Loh, Poh Chiang
    Blaabjerg, Frede
    2015 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION (ECCE), 2015, : 5137 - 5144
  • [22] Current control strategy based on pole placement for grid-connected inverters with LCL filters
    Xu, J. (xjinming01@163.com), 1600, Automation of Electric Power Systems Press (38):
  • [23] Active damping control of grid-connected inverters with LCL filters based on over sampling
    Zhang, Xing
    Chen, Peng
    Yu, Changzhou
    Ni, Hua
    Taiyangneng Xuebao/Acta Energiae Solaris Sinica, 2017, 38 (03): : 767 - 773
  • [24] Magnetic Integration of the LCL Filter in Grid-Connected Inverters
    Pan, Donghua
    Ruan, Xinbo
    Bao, Chenlei
    Li, Weiwei
    Wang, Xuehua
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2014, 29 (04) : 1573 - 1578
  • [25] Optimal design of LCL filter in grid-connected inverters
    Kim, Yong-Jung
    Kim, Hyosung
    IET POWER ELECTRONICS, 2019, 12 (07) : 1774 - 1782
  • [26] Modeling and Stability Analysis of Grid-Connected Inverters with Different LCL Filter Parameters
    Carballo, David
    Escala, Edgar
    Balda, Juan Carlos
    CONFERENCE RECORD OF THE THIRD IEEE INTERNATIONAL WORKSHOP ON ELECTRONIC POWER GRID (EGRID), 2018, : 25 - 30
  • [27] Systematic design of linear quadratic regulator for digitally controlled grid-connected inverters
    Xie, Bao
    Mao, Mingxuan
    Zhou, Lin
    Wan, Yihao
    Hao, Gaofeng
    IET POWER ELECTRONICS, 2020, 13 (03) : 557 - 567
  • [28] Stability Identification for Grid-Connected Inverters with LCL Filters Considering Grid-Voltage Feedforward Regulator
    Lu, Minghui
    Blaabjerg, Frede
    2017 IEEE 18TH WORKSHOP ON CONTROL AND MODELING FOR POWER ELECTRONICS (COMPEL), 2017,
  • [29] Small-Signal Stability Modelling of Grid-Connected Wind Turbine
    Feng, J.
    Xie, D.
    Wang, X.
    2013 INTERNATIONAL CONFERENCE ON INDUSTRIAL ENGINEERING AND MANAGEMENT SCIENCE (ICIEMS 2013), 2013, : 186 - 191
  • [30] Small-Signal Modeling and Analysis of Grid-Connected Inverter with Power Differential Droop Control
    Chen, Xin
    Zhang, Changhua
    Huang, Qi
    Ofori-Oduro, Mark
    MATHEMATICAL PROBLEMS IN ENGINEERING, 2016, 2016