Active damping control of grid-connected inverters with LCL filters based on over sampling

被引:0
|
作者
Zhang, Xing [1 ]
Chen, Peng [1 ]
Yu, Changzhou [1 ]
Ni, Hua [2 ]
机构
[1] School of Electric Engineering and Automation, Hefei University of Technology, Hefei,230009, China
[2] Sungrow Power Supply Co., Ltd., Hefei,230088, China
来源
关键词
Damping - Digital control systems - Bandpass filters - Electric inverters;
D O I
暂无
中图分类号
学科分类号
摘要
The resonant problem is essential for grid-connected inverters with LCL filters, then active damping methods are usually adopted. But the delay caused by digital control affects the active damping control dynamic response performance. In view of the above difficulties, on the basis of the active damping control scheme which based on capacitor voltage feedforward, oversampling is introduced. In a switching period, data is sampled and modulation signal is updated multi times. The control delay is reduced greatly. The scheme can improve active damping control dynamic response performance. Experiment results show that the proposed control scheme is correct and effective. © 2017, Editorial Board of Acta Energiae Solaris Sinica. All right reserved.
引用
收藏
页码:767 / 773
相关论文
共 50 条
  • [1] Virtual RLC Active Damping for Grid-Connected Inverters with LCL Filters
    Huang, Qicheng
    Rajashekara, Kaushik
    [J]. 2017 THIRTY SECOND ANNUAL IEEE APPLIED POWER ELECTRONICS CONFERENCE AND EXPOSITION (APEC), 2017, : 424 - 429
  • [2] Synthesis of Active Damping for Grid-Connected Inverters with an LCL filter
    Xiao, Huafeng
    Qu, Xiaohui
    Xie, Shaojun
    Xu, Jinming
    [J]. 2012 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION (ECCE), 2012, : 550 - 556
  • [3] An Active Damping Method based on PR Control for LCL-Filter-based Grid-Connected Inverters
    Shi, Yong
    Su, Jianhui
    [J]. 2014 17TH INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES AND SYSTEMS (ICEMS), 2014, : 944 - 948
  • [4] Active Damping Control Strategy for Grid-connected Inverters by Splitting the Capacitor of LCL Filter
    Ling Lu
    Ye Yongqiang
    Zhuang Chao
    Wang Jianhong
    [J]. 26TH CHINESE CONTROL AND DECISION CONFERENCE (2014 CCDC), 2014, : 4805 - 4810
  • [5] An Improved Virtual Resistance Damping Method for Grid-Connected Inverters with LCL Filters
    Lei, Yi
    Zhao, Zhengming
    He, Fanbo
    Lu, Sizhao
    Yin, Lu
    [J]. 2011 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION (ECCE), 2011, : 3816 - 3822
  • [6] LCL-resonance damping strategies for grid-connected inverters with LCL filters: a comprehensive review
    Xu, Jinming
    Xie, Shaojun
    [J]. JOURNAL OF MODERN POWER SYSTEMS AND CLEAN ENERGY, 2018, 6 (02) : 292 - 305
  • [7] LCL-resonance damping strategies for grid-connected inverters with LCL filters: a comprehensive review
    Jinming XU
    Shaojun XIE
    [J]. Journal of Modern Power Systems and Clean Energy, 2018, 6 (02) : 292 - 305
  • [8] Adaptive Optimal Control for Parallel Grid-connected Inverters with LCL Filters
    Pan, Shangzhi
    Pahlevaninezhad, Majid
    Jain, Praveen K.
    [J]. 2016 IEEE 7TH INTERNATIONAL SYMPOSIUM ON POWER ELECTRONICS FOR DISTRIBUTED GENERATION SYSTEMS (PEDG), 2016,
  • [9] A robust current control strategy for grid-connected inverters with LCL filters
    Xu, Jinming
    Xie, Shaojun
    Huang, Ruhai
    [J]. Dianli Xitong Zidonghua/Automation of Electric Power Systems, 2012, 36 (19): : 99 - 104
  • [10] Systematic Design of Grid-Current-Based Active Damping for Grid-Connected LCL Filters
    Gaafar, Mahmoud A.
    Dousoky, Gamal M.
    Ahmed, Emad M.
    Shoyama, Masahito
    [J]. 2017 THIRTY SECOND ANNUAL IEEE APPLIED POWER ELECTRONICS CONFERENCE AND EXPOSITION (APEC), 2017, : 2652 - 2657