Fully Automated Electronic Cleansing Using CycleGAN in Computed Tomography Colonography
被引:0
|
作者:
Isobe, Yoshitaka
论文数: 0引用数: 0
h-index: 0
机构:
Fujita Hlth Univ, Grad Sch Hlth Sci, Toyoake, Aichi 4701192, Japan
Japan Community Hlth Care Org, Yokkaichi Hazu Med Ctr, 10-8 Hazuyama, Yokaichi 5100016, JapanFujita Hlth Univ, Grad Sch Hlth Sci, Toyoake, Aichi 4701192, Japan
Isobe, Yoshitaka
[1
,2
]
论文数: 引用数:
h-index:
机构:
Teramoto, Atsushi
[1
]
Morita, Fujio
论文数: 0引用数: 0
h-index: 0
机构:
Japan Community Hlth Care Org, Yokkaichi Hazu Med Ctr, 10-8 Hazuyama, Yokaichi 5100016, JapanFujita Hlth Univ, Grad Sch Hlth Sci, Toyoake, Aichi 4701192, Japan
Morita, Fujio
[2
]
Saito, Kuniaki
论文数: 0引用数: 0
h-index: 0
机构:
Fujita Hlth Univ, Grad Sch Hlth Sci, Toyoake, Aichi 4701192, JapanFujita Hlth Univ, Grad Sch Hlth Sci, Toyoake, Aichi 4701192, Japan
Saito, Kuniaki
[1
]
Fujita, Hiroshi
论文数: 0引用数: 0
h-index: 0
机构:
Gifu Univ, Fac Engn, Gifu 5011194, JapanFujita Hlth Univ, Grad Sch Hlth Sci, Toyoake, Aichi 4701192, Japan
Fujita, Hiroshi
[3
]
机构:
[1] Fujita Hlth Univ, Grad Sch Hlth Sci, Toyoake, Aichi 4701192, Japan
[2] Japan Community Hlth Care Org, Yokkaichi Hazu Med Ctr, 10-8 Hazuyama, Yokaichi 5100016, Japan
CT colonography;
CycleGAN;
deep learning;
CT COLONOGRAPHY;
COLORECTAL-CANCER;
D O I:
10.3390/app122110789
中图分类号:
O6 [化学];
学科分类号:
0703 ;
摘要:
In computed tomography colonography (CTC), an electric cleansing technique is used to mix barium with residual fluid, and colon residue is removed by image processing. However, a nonhomogenous mixture of barium and residue may not be properly removed. We developed an electronic cleansing method using CycleGAN, a deep learning technique, to assist diagnosis in CTC. In this method, an original computed tomography (CT) image taken during a CTC examination and a manually cleansed image in which the barium area was manually removed from the original CT image were prepared and converted to an image in which the barium was removed from the original CT image using CycleGAN. In the experiment, the electric cleansing images obtained using the conventional method were compared with those obtained using the proposed method. The average barium cleansing rates obtained by the conventional and proposed methods were 72.3% and 96.3%, respectively. A visual evaluation of the images showed that it was possible to remove only barium without removing the intestinal tract. Furthermore, the extraction of colorectal polyps and early stage cancerous lesions in the colon was performed as in the conventional method. These results indicate that the proposed method using CycleGAN may be useful for accurately visualizing the colon without barium.