Feasibility of Simultaneous Computed Tomographic Colonography and Fully Automated Bone Mineral Densitometry in a Single Examination

被引:85
|
作者
Summers, Ronald M. [1 ]
Baecher, Nicolai [1 ]
Yao, Jianhua [1 ]
Liu, Jiamin [1 ]
Pickhardt, Perry J. [2 ]
Choi, J. Richard [3 ]
Hill, Suvimol [1 ]
机构
[1] NIH, Imaging Biomarkers & Comp Aided Diag Lab, Radiol & Imaging Sci Dept, Ctr Clin, Bethesda, MD 20892 USA
[2] Univ Wisconsin, Dept Radiol, Sch Med & Publ Hlth, Madison, WI 53706 USA
[3] Walter Reed Army Med Ctr, Washington, DC 20307 USA
基金
美国国家卫生研究院;
关键词
radiology; population studies; bone densitometry; bone QCT; osteoporosis; OLDER US ADULTS; CT COLONOGRAPHY; COLORECTAL ADENOMAS; AIDED DETECTION; CALCIUM SUPPLEMENTATION; QUANTITATIVE CT; 2ND READER; NHANES-III; DENSITY; OSTEOPOROSIS;
D O I
10.1097/RCT.0b013e3182032537
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To show the feasibility of calculating the bone mineral density (BMD) from computed tomographic colonography (CTC) scans using fully automated software. Materials and Methods: Automated BMD measurement software was developed that measures the BMD of the first and second lumbar vertebrae on computed tomography and calculates the mean of the 2 values to provide a per patient BMD estimate. The software was validated in a reference population of 17 consecutive women who underwent quantitative computed tomography and in a population of 475 women from a consecutive series of asymptomatic patients enrolled in a CTC screening trial conducted at 3 medical centers. Results: The mean (SD) BMD was 133.6 (34.6) mg/mL (95% confidence interval, 130.5-136.7; n = 475). In women aged 42 to 60 years (n = 316) and 61 to 79 years (n = 159), the mean (SD) BMDs were 143.1 (33.5) and 114.7 (28.3) mg/mL, respectively (P < 0.0001). Fully automated BMD measurements were reproducible for a given patient with 95% limits of agreement of -9.79 to 8.46 mg/mL for the mean difference between paired assessments on supine and prone CTC. Conclusions: Osteoporosis screening can be performed simultaneously with screening for colorectal polyps.
引用
收藏
页码:212 / 216
页数:5
相关论文
共 50 条
  • [1] Fully automated prone-supine coregistration in computed tomographic colonography
    Davis, Brynmor J.
    Norris, James A.
    Bieszczad, Jerry Y.
    Soto, Jorge A.
    Kynor, David B.
    MEDICAL IMAGING 2011: IMAGE PROCESSING, 2011, 7962
  • [2] Partial preparation computed tomographic colonography: a feasibility study
    Johnson, C. Daniel
    Kriegshauser, J. Scott
    Lund, Jeffrey T.
    Shiff, Arthur D.
    Wu, Qing
    ABDOMINAL IMAGING, 2011, 36 (06): : 707 - 712
  • [3] Partial preparation computed tomographic colonography: a feasibility study
    C. Daniel Johnson
    J. Scott Kriegshauser
    Jeffrey T. Lund
    Arthur D. Shiff
    Qing Wu
    Abdominal Imaging, 2011, 36 : 707 - 712
  • [4] Automated teniae coli detection and identification on computed tomographic colonography
    Wei, Zhuoshi
    Yao, Jianhua
    Wang, Shijun
    Liu, Jiamin
    Summers, Ronald M.
    MEDICAL PHYSICS, 2012, 39 (02) : 964 - 975
  • [5] Fully Automated Electronic Cleansing Using CycleGAN in Computed Tomography Colonography
    Isobe, Yoshitaka
    Teramoto, Atsushi
    Morita, Fujio
    Saito, Kuniaki
    Fujita, Hiroshi
    APPLIED SCIENCES-BASEL, 2022, 12 (21):
  • [6] Automated brain computed tomographic densitometry of early ischemic changes in acute stroke
    Stoel, Brend C.
    Marquering, Henk A.
    Staring, Marius
    Beenen, Ludo F.
    Slump, Cornelis H.
    Roos, Yvo B.
    Majoie, Charles B.
    JOURNAL OF MEDICAL IMAGING, 2015, 2 (01)
  • [7] QUANTITATIVE COMPUTED TOMOGRAPHIC BONE-MINERAL MEASUREMENT
    WILSON, CR
    JAMES, CD
    VOLZ, DJ
    PHYSICS IN MEDICINE AND BIOLOGY, 1980, 25 (05): : 995 - 995
  • [8] Colonoscopy and multidetector-array computed-tomographic colonography: Detection rates and feasibility
    Pedersen, BG
    Christiansen, TEM
    Bjerregaard, NC
    Ljungmann, K
    Laurberg, S
    ENDOSCOPY, 2003, 35 (09) : 736 - 742
  • [9] Computed Tomographic Colonography: Automated Tool for Polyp Measurement Delivering on Patient Risk Stratification
    Bielen, Didier
    Vanslembrouck, Ragna
    De Keyzer, Frederik
    Vandenhout, Hilde
    Guendel, Lutz
    Van Cutsem, Eric
    Marchal, Guy
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2008, 32 (04) : 504 - 510
  • [10] EFFECTS OF VARIATION IN THE SIZE OF THE REGION OF INTEREST ON THE ACCURACY OF COMPUTED TOMOGRAPHIC BONE DENSITOMETRY
    ADAMS, JE
    CARTER, JB
    ADAMS, PH
    BRITISH JOURNAL OF RADIOLOGY, 1986, 59 (704): : 819 - 819