Experimental investigation of a two-phase closed thermosyphon solar water heater

被引:332
|
作者
Esen, M [1 ]
Esen, H [1 ]
机构
[1] Firat Univ, Fac Tech Educ, Dept Mech Educ, TR-23119 Elazig, Turkey
关键词
phase-change; heat-pipe solar collector; refrigerant-charged solar collector; solar water heating;
D O I
10.1016/j.solener.2005.01.001
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
In this study, experiments were performed to find out how the thermal performance of a two-phase thermosyphon solar collector was affected by using different refrigerants. Three identical small-scale solar water heating systems, using refrigerants R-134a, R407C, and R410A, were constructed and tested side-by-side under various environmental and load conditions. The performance of the system under clear-sky conditions has been investigated with and without water load. Detailed temperature distributions and cumulative collection efficiencies were determined and presented. The experimental results were compared to the results found in the literature and they showed good agreement. (c) 2005 Elsevier Ltd. All rights reserved.
引用
收藏
页码:459 / 468
页数:10
相关论文
共 50 条
  • [1] Theoretical and experimental investigations of a two-phase thermosyphon solar water heater
    Chien, C. C.
    Kung, C. K.
    Chang, C. C.
    Lee, W. S.
    Jwo, C. S.
    Chen, S. L.
    [J]. ENERGY, 2011, 36 (01) : 415 - 423
  • [2] Transient investigation of a two phase closed thermosyphon flat plate solar water heater
    Hussein, HMS
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2002, 43 (18) : 2479 - 2492
  • [3] Latent heat storage in a two-phase thermosyphon solar water heater
    Lee, WS
    Chen, BR
    Chen, SL
    [J]. JOURNAL OF SOLAR ENERGY ENGINEERING-TRANSACTIONS OF THE ASME, 2006, 128 (01): : 69 - 76
  • [4] Numerical investigation on effect of riser diameter and inclination on system parameters in a two-phase closed loop thermosyphon solar water heater
    Aung, Nay Zar
    Li, Songjing
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2013, 75 : 25 - 35
  • [5] Experimental investigation of a stainless steel two-phase closed thermosyphon
    Lataoui, Zied
    Jemni, Abdelmajid
    [J]. APPLIED THERMAL ENGINEERING, 2017, 121 : 721 - 727
  • [6] Numerical and experimental investigation of thermosyphon solar water heater
    Zelzouli, Khaled
    Guizani, Amenallah
    Kerkeni, Chakib
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2014, 78 : 913 - 922
  • [7] Experimental and numerical investigation of a thermosyphon solar water heater
    Kohole, Yemeli Wenceslas
    Tchuen, Ghislain
    [J]. INTERNATIONAL JOURNAL OF AMBIENT ENERGY, 2020, 41 (04) : 384 - 394
  • [8] Visualized Experimental Investigation on the Two-phase Instability in a Closed Loop Thermosyphon
    Liu, Yun
    Li, Zhi-Gang
    Li, Yu-Hua
    Jiang, Yu-Yan
    Liang, Shi-Qiang
    [J]. Kung Cheng Je Wu Li Hsueh Pao/Journal of Engineering Thermophysics, 2021, 42 (01): : 215 - 221
  • [9] An experimental and theoretical investigation of the transient behavior of a two-phase closed thermosyphon
    Farsi, H
    Joly, JL
    Miscevic, M
    Platel, V
    Mazet, N
    [J]. APPLIED THERMAL ENGINEERING, 2003, 23 (15) : 1895 - 1912
  • [10] Long-term thermal performance of a two-phase thermosyphon solar water heater
    Chen, Bo-Ren
    Chang, Yu-Wei
    Lee, Wen-Shing
    Chen, Sih-Li
    [J]. SOLAR ENERGY, 2009, 83 (07) : 1048 - 1055