A Case Study on the Impact of Free Air Cooling on Telecom Equipment Performance

被引:0
|
作者
Dai, Jun [1 ]
Das, Diganta [1 ]
Pecht, Michael [1 ]
Ohadi, Michael [1 ]
机构
[1] Univ Maryland, Ctr Adv Life Cycle Engn CALCE, College Pk, MD 20742 USA
关键词
telecom equipment; data center; energy saving; free air cooling; performance variations;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Energy consumption and its environmental impacts have become key concerns in the telecommunications industry and its data centers. As an energy-efficient approach for cooling, some data centers are adopting free air cooling, which uses ambient air outside the data centers, rather than air conditioning, to cool the electronic equipment. Traditionally, telecom equipment qualifications are based on passing a set of tests of industry standards that assume pre-defined environmental conditions. However, free air cooling changes the operating conditions and may go beyond those pre-defined conditions, which may affect the reliability and performance of the telecom equipment. This paper evaluates impact of free air cooling on the performance of telecom equipment. It compares the performance variations of telecom equipment under free air cooling with those under the traditional air conditioning to identify the impact of free air cooling on the telecom equipment performance.
引用
收藏
页码:82 / 86
页数:5
相关论文
共 50 条
  • [1] Prognostics-based risk mitigation for telecom equipment under free air cooling conditions
    Dai, Jun
    Das, Diganta
    Pecht, Michael
    [J]. APPLIED ENERGY, 2012, 99 : 423 - 429
  • [2] Air cooling equipment with high performance and reliability
    Chitrov, E. V.
    Kanter, V. Z.
    Pokhodyaev, S. B.
    Anoshkin, Yu. I.
    [J]. CHEMISTRY AND TECHNOLOGY OF FUELS AND OILS, 2007, 43 (05) : 376 - 381
  • [3] Air cooling equipment with high performance and reliability
    E. V. Chitrov
    V. Z. Kanter
    S. B. Pokhodyaev
    Yu. I. Anoshkin
    [J]. Chemistry and Technology of Fuels and Oils, 2007, 43 : 376 - 381
  • [4] Dual Listing, Corporate Governance and Performance: A Case Study of Zhongxing Telecom Equipment Corporation
    Chen Yun
    He Yuanqiong
    [J]. STRATEGIC MANAGEMENT ENGINEERING: ENTERPRISE, ENVIRONMENT AND CRISIS, 2009, : 856 - 862
  • [5] Impact of competition on telecom sector's performance: A case study of Pakistan
    Hashim, Shumaila
    Khair-Uz-Zaman
    Munir, Akhtar
    Khan, Afnan
    [J]. AFRICAN JOURNAL OF BUSINESS MANAGEMENT, 2011, 5 (22): : 9067 - 9074
  • [6] Liquid Cooling Heat Exchanger for High Density Telecom Equipment
    Le Masson, Stephane
    Nortershauser, David
    Levasseur, Philippe
    [J]. 2018 IEEE INTERNATIONAL TELECOMMUNICATIONS ENERGY CONFERENCE (INTELEC), 2018,
  • [7] Theoretical analysis of the impact of altitude on electrical equipment of air cooling system
    Huang, Yanping
    [J]. Jixie Gongcheng Xuebao/Journal of Mechanical Engineering, 2015, 51 (12): : 153 - 160
  • [8] Characteristic of air jet impingement cooling performance for electronic equipment of satellite
    Liu, Liangtang
    Wang, Anliang
    [J]. Beijing Hangkong Hangtian Daxue Xuebao/Journal of Beijing University of Aeronautics and Astronautics, 2015, 41 (08): : 1553 - 1559
  • [9] Method for optimizing equipment cooling effectiveness and HVAC cooling costs in telecom and data centers
    Herrlin, Magnus K.
    Khankari, Kishor
    [J]. ASHRAE TRANSACTIONS 2008, VOL 114, PT 1, 2008, 114 : 17 - +
  • [10] Cooling performance of free convected thermoelectric air conditioner
    Lertsatitthanakorn, C
    Hirunlabh, J
    Khedari, J
    Scherrer, H
    [J]. TWENTIETH INTERNATIONAL CONFERENCE ON THERMOELECTRICS, PROCEEDINGS, 2001, : 453 - 457