A Case Study on the Impact of Free Air Cooling on Telecom Equipment Performance

被引:0
|
作者
Dai, Jun [1 ]
Das, Diganta [1 ]
Pecht, Michael [1 ]
Ohadi, Michael [1 ]
机构
[1] Univ Maryland, Ctr Adv Life Cycle Engn CALCE, College Pk, MD 20742 USA
关键词
telecom equipment; data center; energy saving; free air cooling; performance variations;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Energy consumption and its environmental impacts have become key concerns in the telecommunications industry and its data centers. As an energy-efficient approach for cooling, some data centers are adopting free air cooling, which uses ambient air outside the data centers, rather than air conditioning, to cool the electronic equipment. Traditionally, telecom equipment qualifications are based on passing a set of tests of industry standards that assume pre-defined environmental conditions. However, free air cooling changes the operating conditions and may go beyond those pre-defined conditions, which may affect the reliability and performance of the telecom equipment. This paper evaluates impact of free air cooling on the performance of telecom equipment. It compares the performance variations of telecom equipment under free air cooling with those under the traditional air conditioning to identify the impact of free air cooling on the telecom equipment performance.
引用
收藏
页码:82 / 86
页数:5
相关论文
共 50 条
  • [31] A case study of thermal performance of gas-steam combined cycle with gas turbine inlet air cooling and condenser deep cooling
    Hu, Hemin
    Wang, Tao
    Ren, Yufei
    Zhang, Fan
    Zhang, Bing
    Li, Jianchao
    [J]. CASE STUDIES IN THERMAL ENGINEERING, 2024, 60
  • [32] Influence of cooling temperature increase in a hygroscopic cycle on the performance of the cooling equipment
    Rubio-Serrano, Francisco J.
    Soto-Perez, Fernando
    Gutierrez-Trashorras, Antonio J.
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2019, 200
  • [33] Load Forecasting and Equipment Sequencing in a Central Heating and Cooling Plant: A Case Study
    Gunay, H. Burak
    Ashouri, Araz
    Shen, Weiming
    [J]. ASHRAE TRANSACTIONS 2019, VOL 125, PT 2, 2019, 125 : 513 - 523
  • [34] Study on steady performance of solar air pretreatment liquid regeneration equipment
    School of Energy and Environment, Southeast University, Nanjing 210096, China
    [J]. Taiyangneng Xuebao, 2009, 2 (163-169):
  • [35] Feasibility of Reducing Electricity Consumption of Air Conditioning Equipment by Condenser Direct Evaporative Cooling Technology. Example of Case Study in Dubai
    Borodinecs, Anatolijs
    Lebedeva, Kristina
    Prozuments, Aleksejs
    Brahmanis, Arturs
    Grekis, Aldis
    Zajecs, Deniss
    Zekunde, Artis
    Vatin, Nikolai
    [J]. ATMOSPHERE, 2021, 12 (09)
  • [36] Free-running temperature and potential for free cooling by ventilation: A case study
    Inard, Christian
    Pfafferott, Jens
    Ghiaus, Christian
    [J]. ENERGY AND BUILDINGS, 2011, 43 (10) : 2705 - 2711
  • [37] Influencing factors analysis of cooling power of air cooling personal thermal protective equipment
    Guo, Xin-Mei
    Yuan, Xiu-Gan
    [J]. Yuhang Xuebao/Journal of Astronautics, 2010, 31 (01): : 276 - 281
  • [38] NEW APPROACH TO COLD MILL DRIVE EQUIPMENT AIR COOLING
    WOODCOCK, JW
    [J]. IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 1979, 15 (06) : 620 - 625
  • [39] OPTIMIZATION OF NATURAL AIR COOLING IN A VERTICAL CHANNEL OF ELECTRONIC EQUIPMENT
    Nishino, Yasushi
    Ishizuka, Masaru
    Hatakeyama, Tomoyuki
    Nakagawa, Shinji
    [J]. PROCEEDINGS OF THE ASME INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION 2010, VOL 4, 2012, : 157 - 165
  • [40] Thermal design of the Electronic Equipment Enclosures with Natural Air Cooling
    Shilo, Galina
    Ogrenich, Evgen
    Kulyaba-Kharitonova, Tatyana
    Buhaiev, Oleh
    [J]. 2019 9TH INTERNATIONAL CONFERENCE ON ADVANCED COMPUTER INFORMATION TECHNOLOGIES (ACIT'2019), 2019, : 153 - 156