2D Translation from a 6-DOF MEMS IMU's Orientation for Freehand 3D Ultrasound Scanning

被引:0
|
作者
Rahni, A. A. Abdul [1 ]
Yahya, I. [1 ]
Mustaza, S. M. [1 ]
机构
[1] Univ Kebangsaan Malaysia, Dept Elect Elect & Syst Engn, Bangi 43600, Selangor, Malaysia
关键词
6-DOF; IMU; HEMS; Freehand 3D Ultrasound Scanning;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
HEMS (Micro Electro-Mechanical Systems) based technology has made it possible to fabricate accelerometers and gyroscopes that are small enough to fit onto chips and thus all the components for a 6-DOF (6 degrees of freedom) IMU (Inertial Measurement Unit) can be enclosed in one compact device. Examples in the market include those from Xsens Technologies B.V. and GLI Interactive LLC. The IMU that is used in this paper is the MT9-B from Xsens where we sought to obtain translational data for use in freehand 3D Ultrasound (3D-US) Scanning. A freehand 3D-US image is constructed from a series of 2D Ultrasound B-scans made with a conventional B-mode scanner scanning across a subject of interest. From the 3D position and orientation (i.e. the 6-DOF parameters) of those B-scans a 3D image can be constructed. The conventional methods of obtaining those parameters in freehand 3D-US scanning are from optical, magnetic, acoustic and articulated-arm tracking. All those methods have some form of limitation and an inertial sensor solution is sought to be an alternative that is not physically intrusive (in the case of articulated-arm tracking) and less dependent of environmental conditions (unlike the remaining three methods). In this paper, orientation output alone is used as translation calculated from acceleration output suffers from drift. The calculation of translation from orientation change is made possible by housing the sensor in a cube of known geometry. The cube is then rolled and `walked' across a plane and its planar translation can then be calculated. We then evaluate the results and assess the feasibility of this method to be applied in freehand 3D-US. Its limitations are expounded upon and improvements are suggested. We hope that this paper would be a good introduction to research using 6-DOF inertial MEMS sensors that have a potentially wide range of applications.
引用
收藏
页码:699 / 702
页数:4
相关论文
共 50 条
  • [41] Hemimegalencephaly: 2D, 3D Ultrasound and MRI Correlation
    Romero, X. C.
    Molina, F. S.
    Pastor, E.
    Amaya, F.
    [J]. FETAL DIAGNOSIS AND THERAPY, 2011, 29 (03) : 257 - 260
  • [42] 2D and 3D Ultrasound Examination of Labia Minora
    Cesare Battaglia
    Bruno Battaglia
    Paolo Busacchi
    Roberto Paradisi
    Maria Cristina Meriggiola
    Stefano Venturoli
    [J]. Archives of Sexual Behavior, 2013, 42 : 153 - 160
  • [43] 2D and 3D Ultrasound Examination of Labia Minora
    Battaglia, Cesare
    Battaglia, Bruno
    Busacchi, Paolo
    Paradisi, Roberto
    Meriggiola, Maria Cristina
    Venturoli, Stefano
    [J]. ARCHIVES OF SEXUAL BEHAVIOR, 2013, 42 (01) : 153 - 160
  • [44] COMPRESSED 3D ULTRASOUND IMAGING WITH 2D ARRAYS
    Birk, Michael
    Burshtein, Amir
    Chernyakova, Tanya
    Eilam, Alon
    Choe, Jung Woo
    Nikoozadeh, Amin
    Khuri-Yakub, Pierre
    Eldar, Yonina C.
    [J]. 2014 IEEE INTERNATIONAL CONFERENCE ON ACOUSTICS, SPEECH AND SIGNAL PROCESSING (ICASSP), 2014,
  • [45] 2D HISTOGRAM ULTRASOUND AND 3D ULTRASOUND CORRELATION IN RHEUMATIC DISEASES
    Mendonca, J. A.
    Provenza, J. R.
    Guissa, V. R.
    Vierhout, C. V.
    Pedri, L. E.
    Frazon, P. G. U.
    Lyrio, A. M.
    Peron Filho, F.
    Bonfiglioli, R.
    Schincariol, N. B.
    [J]. ANNALS OF THE RHEUMATIC DISEASES, 2015, 74 : 1253 - 1254
  • [46] Calibration of an orientation sensor for freehand 3D ultrasound and its use in a hybrid acquisition system
    Housden, Richard James
    Treece, Graham M.
    Gee, Andrew H.
    Prager, Richard W.
    [J]. BIOMEDICAL ENGINEERING ONLINE, 2008, 7 (1)
  • [47] Calibration of an orientation sensor for freehand 3D ultrasound and its use in a hybrid acquisition system
    Richard James Housden
    Graham M Treece
    Andrew H Gee
    Richard W Prager
    [J]. BioMedical Engineering OnLine, 7
  • [48] REAL-TIME MONOCULAR 6-DOF HEAD POSE ESTIMATION FROM SALIENT 2D POINTS
    Barros, Jilliam Maria Diaz
    Garcia, Frederic
    Mirbach, Bruno
    Stricker, Didier
    [J]. 2017 24TH IEEE INTERNATIONAL CONFERENCE ON IMAGE PROCESSING (ICIP), 2017, : 121 - 125
  • [49] Validation of a scanning technique with minimal compression for measuring muscle volume with freehand 3D ultrasound
    Huet, J.
    Boureau, A. -S.
    Sarcher, A.
    Cornu, C.
    Nordez, A.
    [J]. JOURNAL OF BIOMECHANICS, 2024, 162
  • [50] A pathway from 3D to 2D
    Fichthorn K.
    [J]. Nature Materials, 2019, 18 (09) : 911 - 912